Impedance Matching Method for Magnetic Resonance Coupling Human Body Communication
被引:1
作者:
Zheng, Yupei
论文数: 0引用数: 0
h-index: 0
机构:
Fuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R ChinaFuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R China
Zheng, Yupei
[1
]
Wei, Ziliang
论文数: 0引用数: 0
h-index: 0
机构:
Fuzhou Univ, Sch Phys & Informat Engn, Fuzhou 350100, Peoples R ChinaFuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R China
Wei, Ziliang
[2
]
Yan, Hongli
论文数: 0引用数: 0
h-index: 0
机构:
Fuzhou Univ, Sch Phys & Informat Engn, Fuzhou 350100, Peoples R ChinaFuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R China
Yan, Hongli
[2
]
Huang, Lixuan
论文数: 0引用数: 0
h-index: 0
机构:
Fuzhou Univ, Sch Phys & Informat Engn, Fuzhou 350100, Peoples R ChinaFuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R China
Huang, Lixuan
[2
]
Gao, Yueming
论文数: 0引用数: 0
h-index: 0
机构:
Fuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R China
Fuzhou Univ, Sch Phys & Informat Engn, Fuzhou 350100, Peoples R ChinaFuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R China
Gao, Yueming
[1
,2
]
机构:
[1] Fuzhou Univ, Sch Adv Mfg, Jinjiang 362200, Peoples R China
[2] Fuzhou Univ, Sch Phys & Informat Engn, Fuzhou 350100, Peoples R China
来源:
2022 IEEE 10TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION, APCAP
|
2022年
关键词:
magnetic resonance coupling;
adjustable capacitor;
impedance matching;
D O I:
10.1109/APCAP56600.2022.10069779
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
The impedance matching is the key to determine the communication quality in wireless communication field of magnetic resonance coupling human body communication. The human body impedance easily affects the resonant frequency between the communication coils, resulting in serious signal attenuation. This paper proposes an impedance matching method based on dual adjustable capacitors: series resistors are used to adjust the coil bandwidth, while dual adjustable capacitors are used to tune the resonant frequency to the preset resonant frequency and achieve conjugate matching. Using a vector network analyzer to experiment with five volunteers for dual-arm magnetic resonance coupling communication. The experimental results show that the path loss result obtained by applying adjustable impedance matching is 10.88dB lower than that of the single capacitor matching and 7.42dB lower than that of the dual capacitor matching when the distance is 60cm at 13.56MHz. This method solves the issue of impedance mismatch due to the parasitic capacitance of the human body, which provides an effective method for transmission of magnetic resonance coupling human body communication.
引用
收藏
页数:2
相关论文
共 7 条
[1]
Banou S, 2020, IEEE INFOCOM SER, P1549, DOI [10.1109/INFOCOM41043.2020.9155421, 10.1109/infocom41043.2020.9155421]