Facile one-step direct electrodeposition of bismuth nanowires on glassy carbon electrode for selective determination of folic acid

被引:45
作者
Ananthi, Arjunan [1 ]
Kumar, Shanmugam Senthil [1 ]
Phani, Kanala Lakshminarasimha [1 ]
机构
[1] CSIR, Cent Electrochem Res Inst, Nanoscale Electrocatalysis Grp, Electrod & Electrocatalysis Div, Karaikkudi 630006, Tamil Nadu, India
关键词
Bismuth nanowires; in-situ generated hydrogen bubbles; stagnant template; folic acid; ADSORPTIVE STRIPPING VOLTAMMETRY; ELECTROCHEMICAL-BEHAVIOR; PASTE ELECTRODE; FILM ELECTRODE; NANOTUBES; SENSOR; NANOPARTICLES; DEPOSITION;
D O I
10.1016/j.electacta.2014.11.069
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In the present work, we have developed a facile one step route to electrodeposition of stabilizer-free bismuth nanowires (BiNWs) on glassy carbon (GC) substrates by using a simple potentiostatic method. Formation of BiNWs on GC substrate was confirmed by field emission scanning electron microscopy (FE-SEM). The growth of BiNWs on the GC substrate was monitored by cyclic voltammetry and found that continuous in-situ generation of hydrogen bubbles during electrodeposition provides a stagnant template for the formation of BiNWs on the GC substrate. Phase-purity of the deposited BiNWs on GC substrate studied by XRD indicates no other oxide formation. The electrodeposited BiNWs on GC substrate was used for electro-reduction of folic acid (FA) and its quantitative determination in BrittonRobinson buffer of pH 4.5 solutions. The observed cyclic voltammetric reduction current of FA on BiNWs/GC is almost 15 times higher with 0.015 V less negative overpotential compared to bare GC substrate alone. This result clearly reveals the electrocatalytic activity of the deposited BiNWs. In addition, square wave voltammetry (SWV) showed a perfectly linear response in the concentration range of 1 x 10(-8)-15 x 10(-8) mol L-1 with a correlation coefficient of 0.9956. The limit of detection (LOD) and limit of quantitation (LOQ) are determined to be 9.53 x 10(-9) and 31.68 x 10(-9) mol L-1 respectively. The response of the BiNWs/GC sensor matrix is not affected by any usual interference from excess concentrations of metal ions and biomolecules such as ascorbic acid, dopamine, and glucose. Further, we have also performed real sample analysis using pharmaceutical tablets containing folic acid using our BiNWs/GC in the form of recovery studies and the obtained results are found to be in good agreement with the results from high performance liquid chromatography analysis (HPLC). Based on the experimental results, it may be stated that the electrodeposited BiNWs/GC could be an ideal sensor platform for FA determination and may open up applications in biosensor design. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:584 / 590
页数:7
相关论文
共 50 条
[1]   ADSORPTIVE STRIPPING VOLTAMMETRIC BEHAVIOR OF FOLIC-ACID [J].
ALVAREZ, JMF ;
GARCIA, AC ;
ORDIERES, AJM ;
BLANCO, PT .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 225 (1-2) :241-253
[2]   FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF FOLIC-ACID IN PHARMACEUTICAL FORMULATIONS [J].
ALWARTHAN, AA .
ANALYTICAL SCIENCES, 1994, 10 (06) :919-922
[3]   Chemiluminometric and fluorimetric determination of folic acid [J].
Anastasopoulos, Panagiotis ;
Mellos, Triantafillos ;
Spinou, Magdalini ;
Tsiaka, Thalia ;
Timotheou-Potamia, Meropi .
ANALYTICAL LETTERS, 2007, 40 (11) :2203-2216
[4]   Voltammetric detection of riboflavin based on ordered mesoporous carbon modified electrode [J].
Bai, Jing ;
Ndamanisha, Jean Chrysostome ;
Liu, Lin ;
Yang, Li ;
Guo, Liping .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (12) :2251-2256
[5]   The determination of cysteine at Bi-powder carbon paste electrodes by cathodic stripping voltammetry [J].
Baldrianova, L. ;
Agrafiotou, P. ;
Svancara, I. ;
Vytras, K. ;
Sotiropouios, S. .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (06) :918-921
[6]   Novel 2,2′-[1,2-ethanediylbis(nitriloethylidyne)]-bis-hydroquinone double-wall carbon nanotube paste electrode for simultaneous determination of epinephrine, uric acid and folic acid [J].
Beitollahi, Hadi ;
Mazloum-Ardakani, Mohammad ;
Ganjipour, Bahram ;
Naeimi, Hossein .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (03) :362-368
[7]   Application of bismuth-film electrode for cathodic electroanalytical determination of sulfadiazine [J].
Campestrini, Iolana ;
de Braga, Otoniel C. ;
Vieira, Iolanda C. ;
Spinelli, Almir .
ELECTROCHIMICA ACTA, 2010, 55 (17) :4970-4975
[8]   Electrochemical sensing and biosensing based on square wave voltammetry [J].
Chen, Aicheng ;
Shah, Badal .
ANALYTICAL METHODS, 2013, 5 (09) :2158-2173
[9]  
Chilane J., 2013, ANAL CHEM, V85, P11593
[10]   Differential Pulse Voltammetric Determination of Paraquat Using a Bismuth-Film Electrode [J].
de Figueiredo-Filho, Luiz Carlos S. ;
dos Santos, Vagner B. ;
Janegitz, Bruno Campos ;
Guerreiro, Thiago Brito ;
Fatibello-Filho, Orlando ;
Faria, Ronald Censi ;
Marcolino-Junior, Luiz Humberto .
ELECTROANALYSIS, 2010, 22 (11) :1260-1266