Local climate effects of urban wind corridors in Beijing

被引:18
作者
Liu, Yonghong [1 ,2 ]
Xuan, Chunyi [3 ]
Xu, Yongming [4 ]
Fu, Ning [5 ]
Xiong, Feilin [3 ]
Gan, Lu [6 ]
机构
[1] CMA Earth Syst Modeling & Predict Ctr, Beijing 100081, Peoples R China
[2] State Key Lab Severe Weather, Beijing 100081, Peoples R China
[3] Beijing Municipal Climate Ctr, Beijing 100089, Peoples R China
[4] Nanjing Univ Informat Sci & Technol, Sch Remote Sensing & Geomat Engn, Nanjing 210044, Peoples R China
[5] Civil Aviat Univ China, Tianjin 300300, Peoples R China
[6] Beijing Municipal Weather Forecast Ctr, Beijing 100089, Peoples R China
基金
国家重点研发计划;
关键词
Wind corridors; Wind speed ratio; Ventilation benefit; Heat island mitigation; Spatial landscape; Beijing; HEAT; ENVIRONMENT; IMPACT; CITIES; MODEL; LAKE;
D O I
10.1016/j.uclim.2022.101181
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Based on a summer observational experiment and the meteorological data from 2009 to 2018, this paper investigated the local climate effects of representative 1 Level One and 2 Level Two wind corridors (LOC and LTCs, respectively) in the central urban area (CUA) of Beijing by introducing the wind speed ratio (WsR) and urban heat island (UHI) intensity indices. In addition, the impacts on the ventilation of wind corridors from the 8 spatial landscape parameters were analyzed. The results indicated that LOC and LTCs have significant ventilation benefit and certain UHI mitigation benefit varying with season, day and night and weather, which were able to accelerate winds when wind speeds exceed 0.57 m/s and 0.75 m/s, respectively. The most important influencing parameters on the ventilation capability were frontal area index and roughness length. The multiyear average WsRs of the LOC and LTCs were 57% and 31% higher than that of the CUA, respectively. The UHI reduction did not occur along the whole corridor or throughout the whole day. The maximum seasonal mean UHI reduction of the LOC during daytime and nighttime were 0.89 ? and 0.75 ?, respectively. The LTCs mainly reduced UHI during daytime with the maximum reduction of 0.30 ?.
引用
收藏
页数:16
相关论文
共 58 条
[1]   Application of climatic guidelines to urban planning The example of Lisbon (Portugal) [J].
Alcoforado, Maria-Joao ;
Andrade, Henrique ;
Lopes, Antonio ;
Vasconcelos, Joao .
LANDSCAPE AND URBAN PLANNING, 2009, 90 (1-2) :56-65
[2]  
[Anonymous], 2005, HONG KONG I ARCHITEC
[3]  
[Anonymous], 2018, 4362018 QX T CHIN ME, P1
[4]  
Baumller J., 1999, DEMANDS REQUIREMENTS
[5]  
Chen H., 2014, Mod. Urban Res, V7, P24, DOI DOI 10.3969/J.ISSN.1009-6000.2014.07.004
[6]   Quantitative urban climate mapping based on a geographical database: A simulation approach using Hong Kong as a case study [J].
Chen, Liang ;
Ng, Edward .
INTERNATIONAL JOURNAL OF APPLIED EARTH OBSERVATION AND GEOINFORMATION, 2011, 13 (04) :586-594
[7]   Using computational tools to factor wind into architectural environment design [J].
Chen, QY .
ENERGY AND BUILDINGS, 2004, 36 (12) :1197-1209
[8]  
China Meteorological Administration (CMA), 2018, 4372018 QX T CHIN ME
[9]  
Du W.P., 2017, CHIN LANDSC ARCHITEC, V33, P35
[10]  
[杜吴鹏 Du Wupeng], 2016, [城市规划学刊, Urban Planning Forum], P79