Cavitation caused by mechanical heart valve prostheses - A review

被引:0
|
作者
Johansen, P
Travis, BR
Paulsen, PK
Nygaard, H
Hasenkam, JM
机构
[1] Aarhus Univ Hosp, Dept Cardiothorac & Vasc Surg, Skejby, Denmark
[2] Aarhus Univ Hosp, Inst Expt Clin Res, Skejby, Denmark
关键词
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Heart valve dysfunction often necessitates surgical implantation of a mechanical heart valve (MHV). Although implantation of a MHV is a life-saving procedure, the patient still faces potentially complications such as thromboembolic events and material failure. These complications may be caused by cavitation, which can occur during valve closure. Cavitation is an erosive phenomenon that can be generated in fluids when the pressure locally drops below the vapor pressure. This paper reviews the literature on cavitation and MHVs and explains the particular features of the valve and closing conditions that potentially increase the intensity of cavitation. Techniques for detecting cavitation will be discussed. Of these, an acoustic approach will be emphasized, since it is currently the only technique able to detect and quantify cavitation in vivo.
引用
收藏
页码:108 / 112
页数:5
相关论文
共 50 条
  • [21] In vivo demonstration of cavitation potential of a mechanical heart valve
    Dexter, EU
    Aluri, S
    Radcliffe, RR
    Zhu, H
    Carlson, DD
    Heilman, TE
    Chandran, KB
    Richenbacher, WE
    ASAIO JOURNAL, 1999, 45 (05) : 436 - 441
  • [22] Mechanisms of mechanical heart valve cavitation in an electrohydraulic total artificial heart
    Lee, H
    Taenaka, Y
    Kitamura, S
    ASAIO JOURNAL, 2005, 51 (03) : 208 - 213
  • [23] Comparison of Biological and Mechanical Prostheses for Heart Valve Surgery: A Systematic Review of Randomized Controlled Trials
    Kiyose, Alberto Takeshi
    Suzumura, Erica Aranha
    Laranjeira, Ligia
    Buehler, Anna Maria
    Espirito Santo, Jose Amalth
    Berwanger, Otavio
    de Camargo Carvalho, Antonio Carlos
    de Paola, Angelo Amato
    Moises, Valdir Ambrosio
    Cavalcanti, Alexandre Biasi
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2019, 112 (03) : 292 - 301
  • [24] Thrombosis of mechanical heart valve prostheses: revisiting the role of fluoroscopy
    Montorsi, P
    Cavoretto, D
    Ballerini, G
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (865): : 76 - 79
  • [25] An unexplained cluster of thrombosed bileaflet mechanical heart valve prostheses
    Chaudhuri, N
    Hickey, MS
    Spyt, TJ
    ANNALS OF THORACIC SURGERY, 1999, 67 (05): : 1542 - 1543
  • [26] Density and pore structure of pyrocarbon for mechanical heart valve prostheses
    Zhang, Jianhui
    Song, Yinchao
    Gongneng Cailiao/Journal of Functional Materials, 2015, 46 (09): : 09072 - 09075
  • [27] Fifteen years of experience with ATS mechanical heart valve prostheses
    Sezai, Akira
    Hata, Mitsumasa
    Niino, Tetsuya
    Yoshitake, Isamu
    Kasamaki, Yuji
    Hirayama, Atsushi
    Minami, Kazutomo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (06): : 1494 - 1500
  • [28] Twelve years of experience with the ATS mechanical heart valve prostheses
    Taniguchi S.
    Hashizume K.
    Ariyoshi T.
    Hisata Y.
    Tanigawa K.
    Miura T.
    Odate T.
    Matsukuma S.
    Nakaji S.
    Eishi K.
    General Thoracic and Cardiovascular Surgery, 2012, 60 (9) : 561 - 568
  • [29] MECHANICAL FRAGILITY OF ERYTHROCYTES IN NORMALS AND IN PATIENTS WITH HEART VALVE PROSTHESES
    DALE, J
    MYHRE, E
    ACTA MEDICA SCANDINAVICA, 1971, 190 (1-2): : 127 - +
  • [30] Statistical characteristics of mechanical heart valve cavitation in accelerated testing
    Wu, CF
    Hwang, NHC
    Lin, YKM
    JOURNAL OF HEART VALVE DISEASE, 2004, 13 (04): : 659 - 666