Reconstructed versus real-time 3-dimensional echocardiography: Comparison with magnetic resonance imaging

被引:38
作者
Jenkins, Carly [1 ]
Leano, Rodel [1 ]
Chan, Jonathan [1 ]
Marwick, Thomas H. [1 ]
机构
[1] Univ Queensland, Dept Med, Princess Alexandra Hosp, Brisbane, Qld 4102, Australia
关键词
D O I
10.1016/j.echo.2006.12.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The accuracy, reproducibility, and testretest refiability of 3-dimensional (3D) echocardiography (3DE) with 3D reconstruction ODR) and real-time (RT) imaging (RT 3DE) exceed that of 2-dimensional echocardiography (2DE). However, image quality with RT 3DE is inferior to 2DE and we sought to determine whether this justified ongoing use of 3DR. Methods: Unselected patients (n = 30, 22 men, age 66 +/- 7 years) presenting to the echocardiography laboratory for left ventricular (LV) evaluation were studied with 2DE and RT 3DE; 3DR images were ohtained using external localization. The 3D measurements and reconstructions were obtained offfine. Magnetic resonance images (MRI) were obtained using true free induction, steady state precession during breath hold and 3D volumes and ejection fraction (EF) were measured using 3D software. A separate cohort of 20 patients (13 men, age 60 +/- 12 years) was measured for test-retest variation. Results: All. echocardiographic measures underestimated LV volumes and EF compared with MRI, but this was least with RT 3DE. End-diastolic volume by MRI (168 +/- 54 mL) was underestimated by RT 3DE (- 15 +/- 31, P =.02), 3DR (- 26 +/- 33, P <.01), and 2DE (-57 +/- 40, P <.01). Similarly, end-systolic volume by MRI (86 :+/- 50 mL) was underestimated by RT 3DE (- 15 +/- 31, P =.02), 3DR (- 26 +/- 33, P <.01), and 2DE (- 57 +/- 40, P <.01). However, EF measurements were similar with each method. Test-retest variation was less and interobserver and intraobserver correlations were better with RT 3DE for volumes and EF, compared with 3DR and 2DE. Conclusions: Despite limitations of image quality, RT 3DE is the most feasible and accurate approach for LV volume and EF measurements and follow-up LV assessment in daily practice.
引用
收藏
页码:862 / 868
页数:7
相关论文
共 13 条
[1]   MAGNETIC-RESONANCE-IMAGING COMPARED TO ECHOCARDIOGRAPHY TO ASSESS LEFT-VENTRICULAR MASS IN THE HYPERTENSIVE PATIENT [J].
BOTTINI, PB ;
CARR, AA ;
PRISANT, LM ;
FLICKINGER, FW ;
ALLISON, JD ;
GOTTDIENER, JS .
AMERICAN JOURNAL OF HYPERTENSION, 1995, 8 (03) :221-228
[2]   ACC/AHA/ASE 2003 guideline update for the clinical application of Echocardiography: Summary article [J].
Cheitlin, MD ;
Armstrong, WF ;
Aurigemma, GP ;
Beller, GA ;
Bierman, FZ ;
Davis, JL ;
Douglas, PS ;
Faxon, DP ;
Gillam, LD ;
Kimball, TR ;
Kussmaul, WG ;
Pearlman, AS ;
Philbrick, JT ;
Rakowski, H ;
Thys, DM ;
Antman, EM ;
Smith, SC ;
Alpert, JS ;
Gregoratos, G ;
Anderson, JL ;
Hiratzka, LF ;
Faxon, DP ;
Hunt, SA ;
Fuster, V ;
Jacobs, AK ;
Gibbons, RJ ;
Russell, RO .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (10) :1091-1110
[3]   Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction - Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging [J].
Chuang, ML ;
Hibberd, MG ;
Salton, CJ ;
Beaudin, RA ;
Riley, MF ;
Parker, RA ;
Douglas, PS ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) :477-484
[4]   Effects of carvedilol on left ventricular remodeling after acute myocardial infarction -: The CAPRICORN echo substudy [J].
Doughty, RN ;
Whalley, GA ;
Walsh, HA ;
Gamble, GD ;
López-Sendón, J ;
Sharpe, N .
CIRCULATION, 2004, 109 (02) :201-206
[5]   ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS [J].
GOPAL, AS ;
SHEN, ZQ ;
SAPIN, PM ;
KELLER, AM ;
SCHNELLBAECHER, MJ ;
LEIBOWITZ, DW ;
AKINBOBOYE, OO ;
RODNEY, RA ;
BLOOD, DK ;
KING, DL .
CIRCULATION, 1995, 92 (04) :842-853
[6]   Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction [J].
Hibberd, MG ;
Chuang, ML ;
Beaudin, RA ;
Riley, MF ;
Mooney, MG ;
Fearnside, JT ;
Manning, WJ ;
Douglas, PS .
AMERICAN HEART JOURNAL, 2000, 140 (03) :469-475
[7]   Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data [J].
Jacobs, LD ;
Salgo, IS ;
Goonewardena, S ;
Weinert, L ;
Coon, P ;
Bardo, D ;
Gerard, O ;
Allain, P ;
Zamorano, JL ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
EUROPEAN HEART JOURNAL, 2006, 27 (04) :460-468
[8]   Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography [J].
Jenkins, C ;
Bricknell, K ;
Hanekom, L ;
Marwick, TH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) :878-886
[9]   Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters [J].
Jenkins, Carly ;
Chan, Jonathan ;
Hanekom, Lizelle ;
Marwick, Thomas H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (09) :1119-1128
[10]   Rapid freehand scanning three-dimensional echocardiography: Accurate measurement of left ventricular volumes and ejection fraction compared with quantitative gated scintigraphy [J].
Kawai, J ;
Tanabe, K ;
Morioka, S ;
Shiotani, H .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (02) :110-115