摘要
In this study, partially disposable piezoelectric micropumps with separable design have been developed and discussed. The actuator, a rectangular piezo-plate, can be separated and be used repeatedly while the pump chamber is single-use to prevent infection. Thus, a low cost and waste solution for biomedical uses is achieved. Central bossed design of diaphragm was used to achieve self-return in supply mode. More, pump chambers with different depths and diameters have been made. The maximum flow rate, 15.03 ml/min, is reached under 60V actuated voltage.
引用
收藏
页码:1426 / 1429
页数:4
相关论文
共 11 条
  • [1] Thin-film shape-memory alloy actuated micropumps
    Benard, WL
    Kahn, H
    Heuer, AH
    Huff, MA
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1998, 7 (02) : 245 - 251
  • [2] A plastic micropump constructed with conventional techniques and materials
    Böhm, S
    Olthuis, W
    Bergveld, P
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1999, 77 (03) : 223 - 228
  • [3] Analytical static modelling and optimization of electrostatic micropumps
    Francais, O
    Dufour, I
    Sarraute, E
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (03) : 183 - 185
  • [4] Disposable thermo-pneumatic micropurnp for bio lab-on-a-chip application
    Ha, Seung-Mo
    Cho, Woong
    Ahn, Yoomin
    [J]. MICROELECTRONIC ENGINEERING, 2009, 86 (4-6) : 1337 - 1339
  • [5] A disposable piezoelectric micropump with high performance for closed-loop insulin therapy system
    Liu, Guojun
    Shen, Chuanliang
    Yang, Zhigang
    Cai, Xinxia
    Zhang, Honghai
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2010, 163 (01) : 291 - 296
  • [6] The improved performance of one-side actuating diaphragm micropump for a liquid cooling system
    Ma, Hsiao-Kang
    Hou, Bo-Ren
    Lin, Cheng-Yao
    Gao, Jhong-Jhih
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (08) : 957 - 966
  • [7] Nisar A., 2008, SENSOR ACTUATOR, VB130, P917
  • [8] Diffuser-element design investigation for valve-less pumps
    Olsson, A
    Stemme, G
    Stemme, E
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1996, 57 (02) : 137 - 143
  • [9] Review of MEMS-based drug delivery and dosing systems
    Tsai, Nan-Chyuan
    Sue, Chung-Yang
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2007, 134 (02) : 555 - 564
  • [10] Simulations and analysis of a piezoelectric micropump
    Wang, Baowei
    Chu, Xiangcheng
    Li, Enzhu
    Li, Longtu
    [J]. ULTRASONICS, 2006, 44 : E643 - E646