A paper based microfluidic device for the detection of arsenic using a gold nanosensor

被引:85
作者
Nath, Peuli [1 ,2 ]
Arun, Ravi Kumar [1 ,2 ]
Chanda, Nripen [1 ,2 ]
机构
[1] CSIR, Cent Mech Engn Res Inst, Micro Syst Technol Lab, Durgapur 713209, India
[2] AcSIR, New Delhi 110001, India
关键词
NANOPARTICLES;
D O I
10.1039/c4ra12946f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A paper based microfluidic device is fabricated that can rapidly detect very lowconcentrations of As3+ ions using a gold nanosensor, Au-TA-TG. This simple but efficient system develops a visible bluish-black colour precipitate due to the formation of nanoparticle aggregates through transverse diffusive mixing of Au-TA-TG with As3+ ions on a paper substrate. The approach is extremely selective for arsenic with a detection limit of 1.0 ppb, which is lower than the WHO's reference standard for drinking water.
引用
收藏
页码:59558 / 59561
页数:4
相关论文
共 50 条
  • [31] Rapid and continuous parametric screening for the synthesis of gold nanocrystals with different morphologies using a microfluidic device
    Ma, Junping
    Li, Cheuk-Wing
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 : 236 - 244
  • [32] Enzyme-Free glucose detection in sweat using 2D inkjet-printed cobalt sulfide anchored on graphene in a paper-based microfluidic device
    Akiiga, Ngutor Simon
    El-Bab, Ahmed Mohamed Rashad Fath
    Yoshihisa, Matsushita
    Abd El-Moneim, Ahmed
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2025, 688 : 490 - 504
  • [33] Determination of Gold Ions in Human Urine Using Genetically Engineered Microorganisms on a Paper Device
    Guo, Kai-Hong
    Chen, Pei-Hsuan
    Lin, Chieh
    Chen, Chien-Fu
    Lee, I-Ren
    Yeh, Yi-Chun
    [J]. ACS SENSORS, 2018, 3 (04): : 744 - 748
  • [34] DMSA-Functionalized Gold Nanorod on Paper for Colorimetric Detection and Estimation of Arsenic (Ill and V) Contamination in Groundwater
    Priyadarshni, Nivedita
    Nath, Peuli
    Nagahanumaiah
    Chanda, Nripen
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (05): : 6264 - 6272
  • [35] Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
    Sriram, Ganesan
    Bhat, Mahesh P.
    Patil, Pravin
    Uthappa, Uluvangada T.
    Jung, Ho-Young
    Altalhi, Tariq
    Kumeria, Tushar
    Aminabhavi, Tejraj M.
    Pai, Ranjith Krishna
    Madhuprasad
    Kurkuri, Mahaveer D.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 : 212 - 227
  • [36] Near-Field Communication Tag for Colorimetric Glutathione Determination with a Paper-Based Microfluidic Device
    Ortiz-Gomez, Inmaculada
    Rivadeneyra, Almudena
    Salmeron, Jose F.
    Orbe-Paya, Ignacio de
    Morales, Diego P.
    Capitan-Vallvey, Luis Fermin
    Salinas-Castillo, Alfonso
    [J]. BIOSENSORS-BASEL, 2023, 13 (02):
  • [37] DNA-Gold Nanozyme-Modified Paper Device for Enhanced Colorimetric Detection of Mercury Ions
    Mao, Min-Xin
    Zheng, Rong
    Peng, Chi-Fang
    Wei, Xin-Lin
    [J]. BIOSENSORS-BASEL, 2020, 10 (12):
  • [38] Rapid detection of urokinase plasminogen activator using flexible paper-based graphene-gold platform
    Sharma, Bipin
    Parajuli, Prakash
    Podila, Ramakrishna
    [J]. BIOINTERPHASES, 2020, 15 (01)
  • [39] Enhanced immunofluorescence detection of a protein marker using a PAA modified ZnO nanorod array-based microfluidic device
    Wu, Zhihua
    Zhao, De
    Hou, Chengyi
    Liu, Lei
    Chen, Jianhua
    Huang, Hui
    Zhang, Qinghong
    Duan, Yourong
    Li, Yaogang
    Wang, Hongzhi
    [J]. NANOSCALE, 2018, 10 (37) : 17663 - 17670
  • [40] A Portable Smart-Phone Readout Device for the Detection of Mercury Contamination Based on an Aptamer-Assay Nanosensor
    Xiao, Wei
    Xiao, Meng
    Fu, Qiangqiang
    Yu, Shiting
    Shen, Haicong
    Bian, Hongfen
    Tang, Yong
    [J]. SENSORS, 2016, 16 (11)