Groebner bases algorithm for optimal PMU placement

被引:12
作者
Becejac, Vladimir [1 ]
Stefanov, Predrag [1 ]
机构
[1] Univ Belgrade, Sch Elect Engn, Dept Power Syst, Belgrade, Serbia
关键词
Phasor measurement unit; Groebner bases; Nonlinear programming; System observability; MEASUREMENT UNIT PLACEMENT; OBSERVABILITY; FORMULATION; NETWORK;
D O I
10.1016/j.ijepes.2019.105427
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper a new method for solving optimal phasor measurement units (PMU) placement problem for full observability in power systems is proposed. A new algorithm is based on forming and solving Groebner bases set of equations for a defined optimization problem. The technique of Groebner bases is applicable wherever the problem may be presented by the set of polynomials and as such, it can be found in a variety of applied mathematics problems. Groebner bases of the set of polynomials represents the canonical form equivalent to the original set, similar to the way the row echelon form for linear systems represents the triangular form of the linear equations set. The canonical form of the Groebner bases polynomials, along with the utilization of recursive algorithms, allows the solution to be effortlessly obtained. Optimal phasor measurement units placement (OPP) problem can be presented in a linear or nonlinear polynomial form, both of which are used in this paper. The settings of OPP problem have been proposed in this paper with the inclusion of zero injection buses (ZIBs), in normal system states and considering contingency related to PMU outage. The problem formulation is defined according to the application of Groebner bases technique. The proposed model is capable of obtaining the full set of optimal solutions instead of only one or partial solutions. The efficiency of the proposed method is tested on IEEE 14-bus, IEEE 24-bus, IEEE 30-bus, IEEE 118-bus and Polish 2383-bus test system and the results are compared with those of some recently reported methods.
引用
收藏
页数:10
相关论文
共 48 条
  • [1] ILP-Based Optimal PMU Placement with the Inclusion of the Effect of a Group of Zero-Injection Buses
    Abdulrahman I.
    Radman G.
    [J]. Journal of Control, Automation and Electrical Systems, 2018, 29 (4) : 512 - 524
  • [2] Optimal PMU placement method for complete topological observability of power system under various contingencies
    Abiri, Ebrahim
    Rashidi, Farzan
    Niknam, Taher
    Salehi, Mohammad Reza
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 61 : 585 - 593
  • [3] Amare K, 2015, NORTH AMER POW SYMP
  • [4] Observability of Hybrid AC/DC Power Systems With Variable-Cost PMUs
    Aminifar, Farrokh
    Fotuhi-Firuzabad, Mahmud
    Safdarian, Amir
    Shahidehpour, Mohammad
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (01) : 345 - 352
  • [5] [Anonymous], 1994, An Introduction to Groebner Bases
  • [6] [Anonymous], 2007, IDEALS VARIETIES ALG, DOI DOI 10.1007/978-0-387-35651-8
  • [7] [Anonymous], P IEEE PES GEN M CAL
  • [8] [Anonymous], 15 NAT POW SYST C NP
  • [9] [Anonymous], 41 N AM POW S
  • [10] [Anonymous], MEDPOWER 2014