摘要
Introduction: While implantable defibrillator shocks save lives, shock can lead to ventricular arrhythmias. However, the mechanism of shock-related proarrhythmia remains unclear. We evaluated the impact of ICD shock on repolarization instability, a factor associated with ventricular arrhythmogenesis. Methods and Results: Sixty-five patients with ICDs underwent ambulatory ECG monitoring during defibrillation testing 3 months postimplant. TWA was analyzed continuously in the time domain during baseline, sedated, and post-shock states. RR, QRS, and QT intervals and catecholamines were also measured continuously. Adequate pre- and post-shock Holter data were recorded in 55 patients, 48 male, mean 64 +/- 12 years, 50 with coronary disease, 48 with prior spontaneous or induced arrhythmia. TWA significantly increased after shock, from 9.6 +/- 0.5 to 11.9 +/- 0.6 mu V, as did QRS duration, epinephrine, and norepinephrine levels, compared with sedated and baseline states. RR intervals decreased minimally. TWA changes with shock were not associated with RR or QRS duration changes, but were associated with changes in epinephrine. Conclusions: ICD shock, even in the sedated state, increases repolarization instability as measured by TWA, an effect mediated in part by sympathetic stimulation. This association between shock and TWA may have important mechanistic and clinical implications for optimization of defibrillation therapy.
引用
收藏
页码:512 / 517
页数:6
相关论文
共 35 条
  • [1] Patients' attitudes toward implanted defibrillator shocks
    Ahmad, M
    Bloomstein, L
    Roelke, M
    Bernstein, AD
    Parsonnet, V
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (06): : 934 - 938
  • [2] Sudden cardiac death unresponsive to implantable defibrillator therapy: An urgent target for clinicians, industry and government
    Anderson, KP
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 14 (02) : 71 - 78
  • [3] Pathophysiological basis and clinical application of T-wave alternans
    Armoundas, AA
    Tomaselli, GF
    Esperer, HD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (02) : 207 - 217
  • [4] Increase in QT/QTc dispersion after low energy cardioversion of chronic persistent atrial fibrillation
    Boriani, G
    Valzania, C
    Biffi, M
    Corazza, I
    Camanini, C
    Martignani, C
    Bacchi, L
    Zannoli, R
    Branzi, A
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 95 (2-3) : 245 - 250
  • [5] ELECTROCARDIOGRAPHIC CHANGES AFTER CARDIOVERSION OF VENTRICULAR ARRHYTHMIAS
    EYSMANN, SB
    MARCHLINSKI, FE
    BUXTON, AE
    JOSEPHSON, ME
    [J]. CIRCULATION, 1986, 73 (01) : 73 - 81
  • [6] A comparison of T-wave alternans, signal averaged electrocardiography and programmed ventricular stimulation for arrhythmia risk stratification
    Gold, MR
    Bloomfield, DM
    Anderson, KP
    El-Sherif, NE
    Wilber, DJ
    Groh, WJ
    Estes, NAM
    Kaufman, ES
    Greenberg, ML
    Rosenbaum, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (07) : 2247 - 2253
  • [7] T wave alternans as a risk predictor in patients with cardiomyopathy and mild-to-moderate heart failure
    Hennersdorf, MG
    Perings, C
    Niebch, V
    Vester, EG
    Strauer, BE
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (09): : 1386 - 1391
  • [8] T wave alternans during exercise and atrial pacing in humans
    Hohnloser, SH
    Klingenheben, T
    Zabel, M
    Li, YG
    Albrecht, P
    Cohen, RJ
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (09) : 987 - 993
  • [9] Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators
    Hurst, TM
    Hinrichs, M
    Breidenbach, C
    Katz, N
    Waldecker, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) : 402 - 408
  • [10] Defibrillation depresses heart sarcoplasmic reticulum calcium pump: a mechanism of postshock dysfunction
    Jones, DL
    Narayanan, N
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (01): : H98 - H105