C1 lateral mass screw-induced occipital neuralgia: a report of two cases

被引:36
作者
Conroy, Eimear [1 ]
Laing, Alan [1 ]
Kenneally, Rory [1 ]
Poynton, A. R. [1 ]
机构
[1] Mater Misericordiae Univ Hosp, Natl Spinal Injuries Unit, Dept Trauma & Orthopaed, Dublin 7, Ireland
关键词
C1 lateral mass screw; Posterior atlantoaxial stabilization; Occipital neuralgia; C2 nerve root; C2 dorsal root ganglion; FIXATION TECHNIQUES; FUSION; PLATE;
D O I
10.1007/s00586-009-1178-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
C1-2 polyaxial screw-rod fixation is a relatively new technique. While recognizing the potential for inadvertent vertebral artery injury, there have been few reports in the literature outlining all the possible complications. Aim of this study is to review all cases of C1 lateral mass screws insertion with emphasis on the evaluation of potential structures at risk during the procedure. We retrospectively reviewed all patients in our unit who had C1 lateral mass screw insertion over a 2-year period. The C1 lateral mass screw was inserted as part of an atlantoaxial stabilization or incorporated into a modular occiput/subaxial construct. Outcome measures included clinical and radiological parameters. Clinical indicators included age, gender, neurologic status, surgical indication and the number of levels stabilized. Intraoperative complications including blood loss, vertebral artery injury or dural tears were recorded. Postoperative pain distribution and neurological deficit were recorded. Radiological indicators included postoperative plain radiographs to assess sagittal alignment and to check for screw malposition or construct failure. A total of 18 lateral mass screws were implanted in 9 patients. There were three male and six female patients who had C1 lateral mass screw insertion in this unit. Two patients had atlantoaxial stabilization for C2 fracture. There were four patients with rheumatoid arthritis whose C1 lateral mass screws were inserted as part of an occipitocervical or subaxial cervical stabilization. There was no vertebral artery injury, no cerebrospinal fluid leak and minimal blood loss in all patients. Three patients developed postoperative occipital neuralgia. This neuralgia was transient, in one of the patients having settled at 6-week follow-up. In the other two patients the neuralgia was unresolved at time of latest follow-up but was adequately controlled with appropriate pain management. Postoperatively no patient had radiographic evidence of construct failure and all demonstrated excellent sagittal alignment. It has been reported that the absence of threads on the upper portion of the long shank screw may protect against neural irritation. However, insertion of the C1 lateral mass screw necessitates careful caudal retraction of the C2 dorsal root ganglion. The insertion point for the C1 lateral mass screw is at the junction of the C1 posterior arch and the midpoint of the posterior inferior part of the C1 lateral mass. Two patients in our series suffered occipital neuralgia post-insertion of C1 lateral mass screws. This highlights the potential for damage to the C2 nerve root during C1 lateral mass screw placement.
引用
收藏
页码:474 / 476
页数:3
相关论文
共 12 条
  • [1] Currier BL., 2004, CURR OPIN ORTHOP, V15, P184, DOI 10.1097/01.bco.0000127817.76306.61
  • [2] Fiore Amory J, 2002, Neurosurg Focus, V12, pE5
  • [3] PLATE AND SCREW FIXATION FOR ATLANTOAXIAL SUBLUXATION
    GOEL, A
    LAHERI, V
    [J]. ACTA NEUROCHIRURGICA, 1994, 129 (1-2) : 47 - 53
  • [4] Atlantoaxial fixation using, plate and screw method: A report of 160 treated patients
    Goel, A
    Desai, KI
    Muzumdar, DP
    [J]. NEUROSURGERY, 2002, 51 (06) : 1351 - 1356
  • [5] ATLANTOAXIAL FUSION WITH TRANSARTICULAR SCREW FIXATION
    GROB, D
    JEANNERET, B
    AEBI, M
    MARKWALDER, TM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (06): : 972 - 976
  • [6] Posterior C1-C2 fusion with polyaxial screw and rod fixation
    Harms, J
    Melcher, RP
    [J]. SPINE, 2001, 26 (22) : 2467 - 2471
  • [7] Biomechanical comparison of five different atlantoaxial posterior fixation techniques
    Henriques, T
    Cunningham, BW
    Olerud, C
    Shimamoto, N
    Lee, GA
    Larsson, S
    McAfee, PA
    [J]. SPINE, 2000, 25 (22) : 2877 - 2883
  • [8] Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    Madawi, AA
    Casey, ATH
    Solanki, GA
    Tuite, G
    Veres, R
    Crockard, HA
    [J]. JOURNAL OF NEUROSURGERY, 1997, 86 (06) : 961 - 968
  • [9] Biomechanical testing of posterior atlantoaxial fixation techniques
    Melcher, RP
    Puttlitz, CM
    Kleinstueck, FS
    Lotz, JC
    Harms, J
    Bradford, DS
    [J]. SPINE, 2002, 27 (22) : 2435 - 2440
  • [10] Troublesome occipital neuralgia developed by C1-C2 harms construct
    Rhee, Woo-Tack
    You, Seung-Hoon
    Kim, Suk-Kyoung
    Lee, Sang-Youl
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2008, 43 (02) : 111 - 113