Twin gestation: An unusual intrauterine contraceptive device failure outcome

被引:0
作者
Koledade, Afolabi Korede [1 ]
Abdullahi, Zubaida G. [1 ]
Adeoye, Tokunbo O. [1 ]
Shittu, Oladapo Sunday [1 ]
机构
[1] Ahmadu Bello Univ, Teaching Hosp, Dept Obstet & Gynaecol, Zaria, Nigeria
关键词
Contraceptive; failure; intrauterine contraceptive device; management; IUD;
D O I
10.4103/njbcs.njbcs_24_19
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The copper-T intrauterine contraceptive device is an effective long-acting reversible contraceptive option. However, there exists a slim chance of failure. The Copper T 380A has a 1 year failure rate of 0.8% and a 12 year cumulative failure rate of 2.2%. On long-term basis, the cumulative life failure rate for Copper T 380A is 22/1000 long-acting contraceptives after a single application from the 1st to 10th year of insertion, comparable to 18.5 for all tubal sterilisation procedures. When failure happens, the patient is usually at the crossroads of either to terminate the pregnancy or continue with the unplanned pregnancy. Therefore, the patient ought to be adequately counselled on management options, which includes termination of pregnancy where there are no restrictive laws, intrauterine contraceptive device (IUCD) removal if accessible otherwise leave in situ with risks of miscarriage, pre-labour rupture of membrane, and pre-term delivery. The patient's choice is usually laden with emotional and psychological adjustments, especially if the IUCD failed with twin gestation, as seen in this case of a 39-year-old multipara who had Copper-T IUCD inserted 6 months after her last delivery. She opted to carry on with the pregnancy despite associated medical conditions. Attempt at IUCD removal failed at 19 weeks gestational age (GA), and she subsequently drained liquor and was delivered of live pre-term babies at 32 weeks GA. The IUCD was picked up extra chorion and not embedded close to the cervical internal os. Her gestational diabetes and hypertension were co-managed with physicians, while the neonatologists managed the pre-term babies before they were all discharged.
引用
收藏
页码:155 / 158
页数:4
相关论文
共 10 条
  • [1] Akinboro A, 2008, Indian J Hum Genet, V14, P41, DOI 10.4103/0971-6866.44104
  • [2] Ameh N, 2007, Niger J Clin Pract, V10, P205
  • [3] Determinants of contraceptive use among Nigerian couples: evidence from the 2013 Demographic and Health Survey
    Sarah R. Blackstone
    Juliet Iwelunmor
    [J]. Contraception and Reproductive Medicine, 2 (1)
  • [4] Dinwoke V. O., 2015, Tropical Journal of Medical Research, V18, P68
  • [5] Contraceptive failure with Copper T380A intrauterine device (IUD): A single tertiary center experience
    Ekiz, Ali
    Ozkose, Burak
    Yucel, Burak
    Eftal, Muhittin
    Adanur, Ahmet
    Yildirim, Gokhan
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (05) : 1087 - 1091
  • [6] Five-year review of copper T intrauterine device use at the University of Calabar Teaching Hospital, Calabar
    Iklaki, Christopher U.
    Agbakwuru, Anthony U.
    Udo, Atim E.
    Abeshi, Sylvester E.
    [J]. OPEN ACCESS JOURNAL OF CONTRACEPTION, 2015, 6 : 143 - 147
  • [7] Kumari Jyoti, 2013, J Midlife Health, V4, P54, DOI 10.4103/0976-7800.109640
  • [8] Ohihoin AG, 2017, BR J MED MED RES, V21, P1
  • [9] Lost intrauterine devices during pregnancy: maternal and fetal outcome after ultrasound-guided extraction. An analysis of 82 cases
    Schiesser, M
    Lapaire, O
    Tercanli, S
    Holzgreve, W
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 23 (05) : 486 - 489
  • [10] Risk factors for IUD failure: results of a large multicentre case-control study
    Thonneau, Patrick
    Almont, Thierry
    de La Rochebrochard, Elise
    Maria, Bernard
    [J]. HUMAN REPRODUCTION, 2006, 21 (10) : 2612 - 2616