Microwire array for giant magneto-impedance detection of magnetic particles for biosensor prototype

被引:70
作者
Chiriac, Horia
Herea, Dumitru-Daniel
Corodeanu, Sorin
机构
[1] Natl Inst Res & Dev Tech Phys IFT, Iasi, Romania
[2] Alexandru Ioan Cuza Univ, Iasi 700506, Romania
关键词
biosensor; magneto-impedance; microwires array; magnetic microparticle; magnetic bead;
D O I
10.1016/j.jmmm.2006.11.207
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new giant magneto-impedance (GMI) biosensor prototype based on a glass-coated microwires array is reported. The optimal measurement conditions and the influence of a liquid suspension of commercially available polymer-based magnetic microparticles on the magneto-impedance (MI) response of the array were studied. The relative change in MI response enlarges as the number of the active microwires increases. The highest variation of 35% was found for 10 active microwires, for a current intensity of 10 mA. Some possible applications of the biosensor prototype are outlined. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 8 条
  • [1] Trends and challenges in biochemical sensors for clinical and environmental monitoring
    Andreescu, S
    Sadik, OA
    [J]. PURE AND APPLIED CHEMISTRY, 2004, 76 (04) : 861 - 878
  • [2] A biosensor based on magnetoresistance technology
    Baselt, DR
    Lee, GU
    Natesan, M
    Metzger, SW
    Sheehan, PE
    Colton, RJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) : 731 - 739
  • [3] GIANT MAGNETIC-FIELD DEPENDENT IMPEDANCE OF AMORPHOUS FECOSIB WIRE
    BEACH, RS
    BERKOWITZ, AE
    [J]. APPLIED PHYSICS LETTERS, 1994, 64 (26) : 3652 - 3654
  • [4] Detection of superparamagnetic markers with GMI-sensors
    Bethke, C
    Yakabchuk, H
    Tarasenko, V
    Hammer, H
    Kisker, E
    Koppers, E
    Christoph, S
    Zirwes, R
    Müller, J
    [J]. TECHNISCHES MESSEN, 2003, 70 (12): : 574 - 576
  • [5] Amorphous glass-covered magnetic wires:: Preparation, properties, applications
    Chiriac, H
    Ovári, TA
    [J]. PROGRESS IN MATERIALS SCIENCE, 1996, 40 (05) : 333 - 407
  • [6] Kumar A, 2000, Nucleic Acids Res, V28, pE71, DOI 10.1093/nar/28.14.e71
  • [7] Magnetic Dynabeads® detection by sensitive element based on giant magnetoimpedance
    Kurlyandskaya, G
    Levit, V
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (08) : 1611 - 1616
  • [8] Giant-magnetoimpedance-based sensitive element as a model for biosensors
    Kurlyandskaya, GV
    Sánchez, ML
    Hernando, B
    Prida, VM
    Gorria, P
    Tejedor, M
    [J]. APPLIED PHYSICS LETTERS, 2003, 82 (18) : 3053 - 3055