New Single-Layered Paper-Based Microfluidic Devices for the Analysis of Nitrite and Glucose Built via Deposition of Adhesive Tape

被引:18
作者
Yu, Peng [1 ]
Deng, Muhan [1 ]
Yang, Yi [1 ]
机构
[1] Xiangtan Univ, Sch Mat Sci & Engn, Key Lab Low Dimens Mat & Applicat Technol, Minist Educ, Xiangtan 411105, Peoples R China
基金
中国国家自然科学基金;
关键词
paper-based microfluidic devices; colorimetry; adhesive tape; nitrite; glucose; COLORIMETRIC DETERMINATION; GOLD NANOPARTICLE; URIC-ACID; FABRICATION; ION; SURFACE; SYSTEM; OXIDE; STEP;
D O I
10.3390/s19194082
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, low-cost technique has been developed for the rapid fabrication of single-layered paper-based microfluidic devices (mu PADs). This technique, for the first time, made use of the deposition of patterned adhesive tape into the filter paper to construct hydrophobic barriers, with the help of toluene. Unlike other reported multi-layered mu PADs that merely made use of adhesive tape as a separate layer for sealing or fluid flow controlling, the patterned adhesive tape was simultaneously dissolved and penetrated into the filter paper, which resulted in the successful transfer of the pattern from the tape to the filter paper. To demonstrate the effectiveness of this approach, nitrite and glucose were individually measured; detection limits as low as 0.015 +/- 0.004 mM and 0.022 +/- 0.006 mM were reported for nitrite and glucose, respectively. Multiplexed analysis of both analytes was also carried out with respective detection limits of 0.048 +/- 0.005 mM and 0.025 +/- 0.006 mM for nitrite and glucose. The application of the method was demonstrated by measuring nitrite and glucose in spiked artificial urine samples and satisfied recovery results were obtained.
引用
收藏
页数:17
相关论文
共 62 条
  • [41] Paper-based analytical device for instrumental-free detection of thiocyanate in saliva as a biomarker of tobacco smoke exposure
    Pena-Pereira, Francisco
    Lavilla, Isela
    Bendicho, Carlos
    [J]. TALANTA, 2016, 147 : 390 - 396
  • [42] URINARY NITRITE IN SYMPTOMATIC AND ASYMPTOMATIC URINARY-INFECTION
    POWELL, HR
    MCCREDIE, DA
    RITCHIE, MA
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1987, 62 (02) : 138 - 140
  • [43] Novel 3D Printed Microfluidic Paper-Based Analytical Device With Integrated Screen-Printed Electrodes for Automated Viscosity Measurements
    Puneeth, S. B.
    Goel, Sanket
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2019, 66 (07) : 3196 - 3201
  • [44] Two Closely Related Iridium(III) Complexes as Colorimetric and Fluorometric Chemodosimeters for Nitrite in Aqueous Solution Operating along Different Modes of Action
    Qinghai, Shu
    Bats, Jan W.
    Schmittel, Michael
    [J]. INORGANIC CHEMISTRY, 2011, 50 (21) : 10531 - 10533
  • [45] Reconfigurable Acrylic-tape Hybrid Microfluidics
    Ren, Yundong
    Ray, Subhrodeep
    Liu, Yuxiang
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [46] Simultaneous determination of renal function biomarkers in urine using a validated paper-based microfluidic analytical device
    Rossini, Eduardo Luiz
    Milani, Maria Izabel
    Carrilho, Emanuel
    Pezza, Leonardo
    Pezza, Helena Redigolo
    [J]. ANALYTICA CHIMICA ACTA, 2018, 997 : 16 - 23
  • [47] Nitrite: A physiological store of nitric oxide and modulator of mitochondrial function
    Shiva, Sruti
    [J]. REDOX BIOLOGY, 2013, 1 (01): : 40 - 44
  • [48] Strasinger S.K., 2014, Urinalysis and Body Fluids, V6th
  • [49] Measurement of nitric oxide production in biological systems by using Griess Reaction assay
    Sun, J
    Zhang, XJ
    Broderick, M
    Fein, H
    [J]. SENSORS, 2003, 3 (08) : 276 - 284
  • [50] Ultrasensitive microfluidic paper-based electrochemical/visual biosensor based on spherical-like cerium dioxide catalyst for miR-21 detection
    Sun, Xiaolu
    Wang, He
    Jian, Yannan
    Lan, Feifei
    Zhang, Lina
    Liu, Haiyun
    Ge, Shenguang
    Yu, Jinghua
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 105 : 218 - 225