Quality assurance of the jaws only-intensity modulated radiation therapy plans for head-and-neck cancer

被引:12
作者
Duong Thanh Tai [1 ,3 ]
Nguyen Dong Son [2 ]
Truong Thi Hong Loan [3 ]
Anson, H. P. W. [4 ]
机构
[1] Dong Nai Gen Hosp, Dept Radiat Oncol, Bien Hoa, Vietnam
[2] Chi Anh Med Technol Co Ltd, Ho Chi Minh, Vietnam
[3] Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh, Vietnam
[4] PTW Asia Pacific Ltd, Hong Kong, Hong Kong, Peoples R China
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2017年 / 38卷
关键词
Intensity-modulated radiation therapy (IMRT); Jaws only IMRT (JO-IMRT); Quality assurance (QA); IONIZATION CHAMBERS; CONVENTIONAL JAWS; IMRT PLANS; OPTIMIZATION; FEASIBILITY;
D O I
10.1016/j.ejmp.2017.05.059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity-modulated radiation therapy (IMRT) is a treatment technique which has become routine in developed countries. In most centers this technique is delivered with multi-leaf collimators (MLCs). However, the use of MLCs is not mandatory. Several oncology centres in developing countries are still using linear accelerators (LINAC) without MLCs, and can potentially deliver IMRT plans with the use of collimator jaws. In this report, we present the results of quality assurance of this Jaws-Only-IMRT (JO-IMRT) technique in treating nasopharyngeal carcinoma (NPC) patients. Twenty-five plans of nasopharyngeal patients were randomly chosen. For each patient, a JO-IMRT plan was generated and a series of pre-treatment verification measurements was performed including (1) point dose measurement with an ionization chamber, (2) planar dose measurement with a 2D-array detector and (3) 3-dimensional dose measurement using a rotatable phantom with a 2D-array detector. The average differences between the measured and TPS-calculated point doses were found to be 1.26 +/- 0.77%, which is within the institution's dose constraint limits. For the planar dose and 3D dose measurements, the average gamma index based on 3%/3 mm criteria were 96.77 +/- 2.33% and 94.72 +/- 2.67%, respectively. Our measurements showed that the JO-IMRT treatment plans applied to the H&N patients were accurate for the treatment delivery based on our established pass criteria. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:148 / 152
页数:5
相关论文
共 19 条
[1]   Intensity-modulation radiotherapy using independent collimators: An algorithm study [J].
Dai, JR ;
Hu, YM .
MEDICAL PHYSICS, 1999, 26 (12) :2562-2570
[2]   Jaws-only IMRT using direct aperture optimization [J].
Earl, M. A. ;
Afghan, M. K. N. ;
Yu, C. X. ;
Jiang, Z. ;
Shepard, D. M. .
MEDICAL PHYSICS, 2007, 34 (01) :307-314
[3]  
Eisbruch A, 2005, PHASE I II STUDY CON
[4]   IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119 [J].
Ezzell, Gary A. ;
Burmeister, Jay W. ;
Dogan, Nesrin ;
LoSasso, Thomas J. ;
Mechalakos, James G. ;
Mihailidis, Dimitris ;
Molineu, Andrea ;
Palta, Jatinder R. ;
Ramsey, Chester R. ;
Salter, Bill J. ;
Shi, Jie ;
Xia, Ping ;
Yue, Ning J. ;
Xiao, Ying .
MEDICAL PHYSICS, 2009, 36 (11) :5359-5373
[5]   Eight years of IMRT quality assurance with ionization chambers and film dosimetry: experience of the montpellier comprehensive cancer center [J].
Fenoglietto, Pascal ;
Laliberte, Benoit ;
Ailleres, Norbert ;
Riou, Olivier ;
Dubois, Jean-Bernard ;
Azria, David .
RADIATION ONCOLOGY, 2011, 6
[6]  
John N, 2006, US Patent, Patent No. 7180980
[7]   A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer [J].
Kim, Yongbok ;
Verhey, Lynn J. ;
Xia, Ping .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08) :2147-2156
[8]   A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments [J].
Kumar, S. A. Syam ;
Sukumar, Prabakar ;
Sriram, Padmanaban ;
Rajasekaran, Dhanabalan ;
Aketi, Srinu ;
Vivekanandan, Nagarajan .
MEDICAL DOSIMETRY, 2012, 37 (04) :436-441
[9]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661
[10]   Dosimetry tools and techniques for IMRT [J].
Low, Daniel A. ;
Moran, Jean M. ;
Dempsey, James F. ;
Dong, Lei ;
Oldham, Mark .
MEDICAL PHYSICS, 2011, 38 (03) :1313-1338