Equivalence of single and incremental subfailure stretches of rabbit anterior cruciate ligament

被引:11
作者
Panjabi, MM [1 ]
Huang, RC [1 ]
Cholewicki, J [1 ]
机构
[1] Yale Univ, Dept Orthopaed & Rehabil, Sch Med, Biomech Lab, New Haven, CT 06520 USA
关键词
D O I
10.1002/jor.1100180524
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Experimental models are often used in the laboratory to produce incomplete soft-tissue injuries simulating those observed clinically. Single and incremental stretch protocols have been utilized. The latter has many advantages over the former. This study was designed to determine if incremental and single ligamentous stretches are biomechanically equivalent. Eleven paired fresh rabbit bone-anterior cruciate ligament-bone preparations were used. One of each pair (single-stretch protocol) was stretched to 88% of the average failure deformation and then stretched to failure. The other ligament (incremental-stretch protocol) was stretched to 55, 66, 77, and 88% of the average failure deformation and then stretched to failure. All stretches were performed at 1.2 m/sec. Stress-relaxation tests were performed before and after the 88% stretch fur both stretch protocols. Relaxation curves were parameterized as forces at six time points and were also fitted to a three-element model. Load-deformation curves recorded during stretch to failure were characterized by eight parameters. Each incremental stretch step produced a significant increase in deformation, indicating alteration in the mechanical properties of the ligament. Both groups of ligaments, when intact, exhibited no differences in relaxation curves (p > 0.2). The 88% stretches, produced by each of the two stretch protocols, significantly altered the viscoelastic behavior of the ligaments (p < 0.002). However, after the 88% stretch, there were no differences in either viscoelastic (p > 0.1) or load-deformation (p > 0.1) parameters of the two stretch protocols. In conclusion, the 88% subfailure stretch significantly altered the mechanical properties of ligament, and the incremental and single stretches were biomechanically equivalent.
引用
收藏
页码:841 / 848
页数:8
相关论文
共 22 条
[1]   COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS [J].
BUTLER, DL ;
KAY, MD ;
STOUFFER, DC .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :425-432
[2]  
BUTLER DL, 1991, T ORTHOP RES SOC, V16, P234
[3]  
CHELIKANI S, 1995, 19 ANN M AM SOC BIOM
[4]   Spinal ligament transducer based on a hall effect sensor [J].
Cholewicki, J ;
Panjabi, MM ;
Nibu, K ;
Macias, ME .
JOURNAL OF BIOMECHANICS, 1997, 30 (03) :291-293
[5]   THE MECHANICAL-PROPERTIES OF SKELETALLY MATURE RABBIT ANTERIOR CRUCIATE LIGAMENT AND PATELLAR TENDON OVER A RANGE OF STRAIN RATES [J].
DANTO, MI ;
WOO, SLY .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (01) :58-67
[6]  
Fung Y.C., 1993, BIOMECHANICS MECH PR, P41
[7]   Whiplash produces an S-shaped curvature of the neck with hyperextension at lower levels [J].
Grauer, JN ;
Panjabi, MM ;
Cholewicki, J ;
Nibu, K ;
Dvorak, J .
SPINE, 1997, 22 (21) :2489-2494
[8]  
HOFFMAN HH, 1998, INT SOC STUD LUMB SP
[9]  
HUANG RC, 1998, THESIS YALE U SCH ME
[10]   THE EFFECTS OF TEMPERATURE ON THE VISCOELASTIC PROPERTIES OF THE RABBIT MEDIAL COLLATERAL LIGAMENT [J].
LAM, TC ;
THOMAS, CG ;
SHRIVE, NG ;
FRANK, CB ;
SABISTON, CP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02) :147-152