摘要
Purpose: Vascular elastography can visualize the strain distribution in the carotid artery, which could be useful in assessing the propensity of advanced plaques to rupture. In our previous studies, we demonstrated that sparse synthetic aperture (SA) imaging can produce high quality vascular strain elastograms. However, the low output power of SA imaging may hamper its clinical utility. In this study, we hypothesize that multi-element defocused emissions can overcome this limitation and improve the quality of the vascular strain elastograms. Methods: To assess the impact of attenuation on the elastographic performance of SA and (multi-element synthetic aperture) MSA imaging, we conducted experiments using heterogeneous vessel phantoms with ideal (0.1 dB cm(-1) MHz(-1)) and realistic (0.75 dB cm(-1) MHz(-1)) attenuation. Further, we validated the results of the phantom study in vivo, on a healthy male volunteer. All echo imaging was performed at a transmit frequency of 5 MHz, using a commercially available ultrasound scanner (Sonix RP, Ultrasonix Medical Corp., Richmond, BC, Canada). Results: The results from the phantom results demonstrated that plaques were visible in all strain elastograms, but those produced using MSA imaging had less artifacts. MSA imaging improved the elastographic contrast to noise ratio (CNRe) of the vascular elastograms by 14.58 dB relative to SA imaging, and 9.1 dB relative to compounded plane wave (CPW) imaging. Further, the results demonstrated that the elastographic performance of MSA imaging improved with increase in (a) the number of transmit-receive events and (b) the size of the transmit sub-aperture, up to 13 elements. Using larger sub-apertures degraded the elastographic performance. The results from the in vivo study were in good agreement with the phantom results. Specifically, using a defocused multi-element transmit sub-aperture for SA imaging improved the performance of vascular elastography. Conclusions: The results suggested that MSA imaging can produce reliable vascular stain elastograms. Future studies will involve using coded excitations to improve the CNRe and frame-rate of the proposed technique for vascular elastography. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4068 / 4082
页数:15
相关论文
共 50 条
[31]   In vivo color flow mapping using synthetic aperture dual stage beamforming [J].
Li, Ye ;
Hansen, Peter Moller ;
Hemmsen, Martin Christian ;
Nielsen, Michael Bachmann ;
Jensen, Jorgen Arendt .
2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, :1592-1595
[32]   Validation of Noninvasive In Vivo Compound Ultrasound Strain Imaging Using Histologic Plaque Vulnerability Features [J].
Hansen, Hendrik H. G. ;
de Borst, Gert Jan ;
Bots, Michiel L. ;
Moll, Frans L. ;
Pasterkamp, Gerard ;
de Korte, Chris L. .
STROKE, 2016, 47 (11) :2770-2775
[33]   Performance Evaluation of Compounding and Directional Beamforming Techniques for Carotid Strain Imaging using Plane Wave Transmissions [J].
Hansen, Hendrik H. G. ;
Stuart, Matthias B. ;
Hoyos, Carlos A. Villagomez ;
Jensen, Jorgen Arendt ;
de Korte, Chris L. .
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, :1814-1817
[34]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[35]   In Vivo Evaluation of Quantitative MR Angiography in a Canine Carotid Artery Stenosis Model [J].
Calderon-Arnulphi, M. ;
Amin-Hanjani, S. ;
Alaraj, A. ;
Zhao, M. ;
Du, X. ;
Ruland, S. ;
Zhou, X. J. ;
Thulborn, K. R. ;
Charbel, F. T. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (08) :1552-1559
[36]   ACOUSTIC RADIATION FORCE IMPULSE IMAGING FOR NONINVASIVE CHARACTERIZATION OF CAROTID ARTERY ATHEROSCLEROTIC PLAQUES: A FEASIBILITY STUDY [J].
Dahl, Jeremy J. ;
Dumont, Douglas M. ;
Allen, Jason D. ;
Miller, Elizabeth M. ;
Trahey, Gregg E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (05) :707-716
[37]   Optimization of the Strain Tensor Estimation For Cross Sectional Non-Invasive Elastography of the Carotid using Plane Wave Imaging [J].
Poree, Jonathan ;
Garcia, Damien ;
Ohayon, Jacques ;
Cloutier, Guy .
2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
[38]   CLINICAL EVALUATION OF SYNTHETIC APERTURE HARMONIC IMAGING FOR SCANNING FOCAL MALIGNANT LIVER LESIONS [J].
Brandt, Andreas Hjelm ;
Hemmsen, Martin Christian ;
Hansen, Peter Moller ;
Madsen, Signe Sloth ;
Krohn, Paul Suno ;
Lange, Theis ;
Hansen, Kristoffer Lindskov ;
Jensen, Jorgen Arendt ;
Nielsen, Michael Bachmann .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (09) :2368-2375
[39]   Synthetic aperture flow imaging using dual stage beamforming: Simulations and experiments [J].
Li, Ye ;
Jensen, Jorgen Arendt .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (04) :2014-2024
[40]   Multi-element synthetic transmit aperture imaging using temporal encoding [J].
Gammelmark, KL ;
Jensen, JA .
MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 :25-36