Noninvasive carotid artery elastography using multielement synthetic aperture imaging: Phantom and in vivo evaluation

被引:17
作者
Nayak, Rohit [1 ]
Schifitto, Giovanni [2 ]
Doyley, Marvin M. [1 ,3 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Med Ctr, Sch Med & Dent, Dept Neurol, Rochester, NY 14622 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
关键词
carotid elastography; plane wave imaging; synthetic aperture imaging; virtual source imaging; FRAME RATE ULTRASONOGRAPHY; PLANE-WAVE; VASCULAR ELASTOGRAPHY; CAP THICKNESS; ULTRASOUND; PLAQUE; RUPTURE; VECTOR;
D O I
10.1002/mp.12329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Vascular elastography can visualize the strain distribution in the carotid artery, which could be useful in assessing the propensity of advanced plaques to rupture. In our previous studies, we demonstrated that sparse synthetic aperture (SA) imaging can produce high quality vascular strain elastograms. However, the low output power of SA imaging may hamper its clinical utility. In this study, we hypothesize that multi-element defocused emissions can overcome this limitation and improve the quality of the vascular strain elastograms. Methods: To assess the impact of attenuation on the elastographic performance of SA and (multi-element synthetic aperture) MSA imaging, we conducted experiments using heterogeneous vessel phantoms with ideal (0.1 dB cm(-1) MHz(-1)) and realistic (0.75 dB cm(-1) MHz(-1)) attenuation. Further, we validated the results of the phantom study in vivo, on a healthy male volunteer. All echo imaging was performed at a transmit frequency of 5 MHz, using a commercially available ultrasound scanner (Sonix RP, Ultrasonix Medical Corp., Richmond, BC, Canada). Results: The results from the phantom results demonstrated that plaques were visible in all strain elastograms, but those produced using MSA imaging had less artifacts. MSA imaging improved the elastographic contrast to noise ratio (CNRe) of the vascular elastograms by 14.58 dB relative to SA imaging, and 9.1 dB relative to compounded plane wave (CPW) imaging. Further, the results demonstrated that the elastographic performance of MSA imaging improved with increase in (a) the number of transmit-receive events and (b) the size of the transmit sub-aperture, up to 13 elements. Using larger sub-apertures degraded the elastographic performance. The results from the in vivo study were in good agreement with the phantom results. Specifically, using a defocused multi-element transmit sub-aperture for SA imaging improved the performance of vascular elastography. Conclusions: The results suggested that MSA imaging can produce reliable vascular stain elastograms. Future studies will involve using coded excitations to improve the CNRe and frame-rate of the proposed technique for vascular elastography. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4068 / 4082
页数:15
相关论文
共 50 条
  • [21] In vivo carotid strain imaging using principal strains in longitudinal view
    Meshram, N. H.
    Mitchell, C. C.
    Wilbrand, S. M.
    Dempsey, R. J.
    Varghese, T.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [22] Imaging of contact acoustic nonlinearity using synthetic aperture technique
    Yun, Dongseok
    Kim, Jongbeom
    Jhang, Kyung-Young
    ULTRASONICS, 2013, 53 (07) : 1349 - 1354
  • [23] Synthetic Aperture Imaging Beyond Foreground Using Image Matting
    Yihua Pan
    Bin Liu
    Wenmin Yan
    Yan Han
    Yi Zhang
    Sensing and Imaging, 2019, 20
  • [24] Synthetic Aperture Imaging Beyond Foreground Using Image Matting
    Pan, Yihua
    Liu, Bin
    Yan, Wenmin
    Han, Yan
    Zhang, Yi
    SENSING AND IMAGING, 2019, 20 (1):
  • [25] PULSE WAVE IMAGING IN CAROTID ARTERY STENOSIS HUMAN PATIENTS IN VIVO
    Li, Ronny X.
    Apostolakis, Iason Z.
    Kemper, Paul
    McGarry, Matthew D. J.
    Ip, Ada
    Connolly, Edward S.
    McKinsey, James F.
    Konofagou, Elisa E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (02) : 353 - 366
  • [26] Clinical evaluation of Synthetic Aperture Sequential Beamforming and Tissue Harmonic Imaging
    Brandt, Andreas Hjelm
    Hemmsen, Martin Christian
    Hansen, Peter Moller
    Hansen, Kristoffer Lindskov
    Lange, Theis
    Jensen, Jorgen Arendt
    Nielsen, Michael Bachmann
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1312 - 1315
  • [27] Modified multi-element synthetic transmit aperture method for ultrasound imaging: A tissue phantom study
    Tasinkevych, Y.
    Klimonda, Z.
    Lewandowski, M.
    Nowicki, A.
    Lewin, A.
    ULTRASONICS, 2013, 53 (02) : 570 - 579
  • [28] Focus Measure for Synthetic Aperture Imaging Using a Deep Convolutional Network
    Pei, Zhao
    Huang, Li
    Zhang, Yanning
    Ma, Miao
    Peng, Yali
    Yang, Yee-Hong
    IEEE ACCESS, 2019, 7 : 19762 - 19774
  • [29] All-In-Focus Synthetic Aperture Imaging Using Image Matting
    Pei, Zhao
    Chen, Xida
    Yang, Yee-Hong
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2018, 28 (02) : 288 - 301
  • [30] Synthetic aperture imaging using pixel labeling via energy minimization
    Pei, Zhao
    Zhang, Yanning
    Chen, Xida
    Yang, Yee-Hong
    PATTERN RECOGNITION, 2013, 46 (01) : 174 - 187