Noninvasive carotid artery elastography using multielement synthetic aperture imaging: Phantom and in vivo evaluation

被引:17
|
作者
Nayak, Rohit [1 ]
Schifitto, Giovanni [2 ]
Doyley, Marvin M. [1 ,3 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Med Ctr, Sch Med & Dent, Dept Neurol, Rochester, NY 14622 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
关键词
carotid elastography; plane wave imaging; synthetic aperture imaging; virtual source imaging; FRAME RATE ULTRASONOGRAPHY; PLANE-WAVE; VASCULAR ELASTOGRAPHY; CAP THICKNESS; ULTRASOUND; PLAQUE; RUPTURE; VECTOR;
D O I
10.1002/mp.12329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Vascular elastography can visualize the strain distribution in the carotid artery, which could be useful in assessing the propensity of advanced plaques to rupture. In our previous studies, we demonstrated that sparse synthetic aperture (SA) imaging can produce high quality vascular strain elastograms. However, the low output power of SA imaging may hamper its clinical utility. In this study, we hypothesize that multi-element defocused emissions can overcome this limitation and improve the quality of the vascular strain elastograms. Methods: To assess the impact of attenuation on the elastographic performance of SA and (multi-element synthetic aperture) MSA imaging, we conducted experiments using heterogeneous vessel phantoms with ideal (0.1 dB cm(-1) MHz(-1)) and realistic (0.75 dB cm(-1) MHz(-1)) attenuation. Further, we validated the results of the phantom study in vivo, on a healthy male volunteer. All echo imaging was performed at a transmit frequency of 5 MHz, using a commercially available ultrasound scanner (Sonix RP, Ultrasonix Medical Corp., Richmond, BC, Canada). Results: The results from the phantom results demonstrated that plaques were visible in all strain elastograms, but those produced using MSA imaging had less artifacts. MSA imaging improved the elastographic contrast to noise ratio (CNRe) of the vascular elastograms by 14.58 dB relative to SA imaging, and 9.1 dB relative to compounded plane wave (CPW) imaging. Further, the results demonstrated that the elastographic performance of MSA imaging improved with increase in (a) the number of transmit-receive events and (b) the size of the transmit sub-aperture, up to 13 elements. Using larger sub-apertures degraded the elastographic performance. The results from the in vivo study were in good agreement with the phantom results. Specifically, using a defocused multi-element transmit sub-aperture for SA imaging improved the performance of vascular elastography. Conclusions: The results suggested that MSA imaging can produce reliable vascular stain elastograms. Future studies will involve using coded excitations to improve the CNRe and frame-rate of the proposed technique for vascular elastography. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:4068 / 4082
页数:15
相关论文
共 50 条
  • [1] VISUALIZING ANGLE-INDEPENDENT PRINCIPAL STRAINS IN THE LONGITUDINAL VIEW OF THE CAROTID ARTERY: PHANTOM AND IN VIVO EVALUATION
    Nayak, Rohit
    Schifitto, Giovanni
    Doyley, Marvin M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (07) : 1379 - 1391
  • [2] Strain Estimation of Carotid Artery using Virtual Element based Synthetic Aperture Imaging
    Nayak, Rohit
    Korukonda, Sanghamithra
    Doyley, Marvin M.
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
  • [3] Evaluation of a Synthetic Aperture Technique for Medical Ultrasound Imaging: Phantom and in vivo Breast study
    Kim, Choye
    Yoon, Changhan
    Kim, Won Hwa
    Chang, Jung Min
    Song, Tai-Kyung
    Yoo, Yangmo
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1287 - 1290
  • [4] Visualizing Angle-Independent Principal Strains in the Longitudinal View of the Carotid Artery: Phantom and In Vivo Evaluation
    Nayak R.
    Schifitto G.
    Doyley M.M.
    Ultrasound in Medicine and Biology, 2018, 44 (07): : 1379 - 1391
  • [5] Improved beamforming for lateral oscillations in elastography using synthetic aperture imaging
    Liebgott, H.
    Basarab, A.
    Loizeau, D.
    Wilhjelm, J. E.
    Jensen, J. A.
    Delachartre, P.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2168 - +
  • [6] In-vivo evaluation of convex array synthetic aperture imaging
    Pedersen, Morten H.
    Gammelmark, Kim L.
    Jensen, Jorgen A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (01) : 37 - 47
  • [7] Carotid Artery Plaque Vulnerability Assessment Using Noninvasive Ultrasound Elastography: Validation With MRI
    Cardinal, Marie-Helene Roy
    Heusinkveld, Maarten H. G.
    Qin, Zhao
    Lopata, Richard G. P.
    Naim, Cyrille
    Soulez, Gilles
    Cloutier, Guy
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (01) : 142 - 151
  • [8] Preliminary in-vivo evaluation of convex array synthetic aperture Imaging
    Pedersen, MH
    Gammelmark, KL
    Jensen, JA
    MEDICAL IMAGING 2004: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2004, 5373 : 33 - 43
  • [9] IN VIVO BLOOD VELOCITY VECTOR IMAGING USING ADAPTIVE VELOCITY COMPOUNDING IN THE CAROTID ARTERY BIFURCATION
    Saris, Anne E. C. M.
    Hansen, Hendrik H. G.
    Fekkes, Stein
    Menssen, Jan
    Nillesen, Maartje M.
    de Korte, Chris L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (07) : 1691 - 1707
  • [10] Pulse wave imaging using coherent compounding in a phantom and in vivo
    Apostolakis, Iason Zacharias
    McGarry, Matthew D. J.
    Bunting, Ethan A.
    Konofagou, Elisa E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05) : 1700 - 1730