Paper-Based Electrical Respiration Sensor

被引:393
作者
Gueder, Firat [1 ]
Ainla, Alar [1 ]
Redston, Julia [1 ]
Mosadegh, Bobak [1 ,2 ]
Glavan, Ana [1 ]
Martin, T. J. [1 ]
Whitesides, George M. [1 ,2 ]
机构
[1] Harvard Univ, Dept Chem & Chem Biol, 12 Oxford St, Cambridge, MA 02138 USA
[2] Harvard Univ, Wyss Inst Biol Inspired Engn, 60 Oxford St, Cambridge, MA 02138 USA
基金
瑞典研究理事会;
关键词
digital health; internet of things; paper; respiration; sensors; CARE;
D O I
10.1002/anie.201511805
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Current methods of monitoring breathing require cumbersome, inconvenient, and often expensive devices; this requirement sets practical limitations on the frequency and duration of measurements. This article describes a paper-based moisture sensor that uses the hygroscopic character of paper (i.e. the ability of paper to adsorb water reversibly from the surrounding environment) to measure patterns and rate of respiration by converting the changes in humidity caused by cycles of inhalation and exhalation to electrical signals. The changing level of humidity that occurs in a cycle causes a corresponding change in the ionic conductivity of the sensor, which can be measured electrically. By combining the paper sensor with conventional electronics, data concerning respiration can be transmitted to a nearby smartphone or tablet computer for post-processing, and subsequently to a cloud server. This means of sensing provides a new, practical method of recording and analyzing patterns of breathing.
引用
收藏
页码:5727 / 5732
页数:6
相关论文
共 41 条
[1]   Respiration Rate Monitoring Methods: A Review [J].
AL-Khalidi, F. Q. ;
Saatchi, R. ;
Burke, D. ;
Elphick, H. ;
Tan, S. .
PEDIATRIC PULMONOLOGY, 2011, 46 (06) :523-529
[2]  
[Anonymous], 2001, HDB PHYS TESTING PAP
[3]   Evaluation of acoustic respiration rate monitoring after extubation in intensive care unit patients [J].
Autet, L. M. ;
Frasca, D. ;
Pinsard, M. ;
Cancel, A. ;
Rousseau, L. ;
Debaene, B. ;
Mimoz, O. .
BRITISH JOURNAL OF ANAESTHESIA, 2014, 113 (01) :195-197
[4]  
Broza Y. Y., 2015, Angew. Chem, V127, P11188, DOI [10.1002/ange.201500153, DOI 10.1002/ANGE.201500153]
[5]   Hybrid Volatolomics and Disease Detection [J].
Broza, Yoav Y. ;
Mochalski, Pawel ;
Ruzsanyi, Vera ;
Amann, Anton ;
Haick, Hossam .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (38) :11036-11048
[6]  
Carey D., 2008, J EX PHYSIOL, V11, P44
[7]  
Carey DG, 2005, J SPORT SCI MED, V4, P482
[8]   End-tidal carbon dioxide concentration monitoring in obstructive sleep apnea patients [J].
Chen Weihu ;
Ye Jingying ;
Han Demin ;
Zhang Yuhuan ;
Wang Jiangyong .
AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2011, 32 (03) :190-193
[9]  
Cretikos MA, 2008, MED J AUSTRALIA, V188, P657
[10]  
Dodds W., 1956, ENG CHEM CHEM ENG DA, V1, P92