Quantitative Analysis and Automated Lung Ultrasound Scoring for Evaluating COVID-19 Pneumonia With Neural Networks

被引:21
作者
Chen, Jiangang [1 ]
He, Chao [2 ]
Yin, Jintao [1 ]
Li, Jiawei [3 ]
Duan, Xiaoqian [1 ]
Cao, Yucheng [1 ]
Sun, Li [1 ]
Hu, Menghan [1 ]
Li, Wenfang [2 ]
Li, Qingli [1 ]
机构
[1] East China Normal Univ, Shanghai Key Lab Multidimens Informat Proc, Shanghai 200241, Peoples R China
[2] Naval Med Univ, Changzheng Hosp, Dept Emergency & Crit Care, Shanghai 200433, Peoples R China
[3] Fudan Univ, Shanghai Canc Ctr, Dept Med Ultrasound, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Automated scoring; COVID-19; pneumonia; lung ultrasound; quantitative analysis; EXTRAVASCULAR LUNG; B-LINES; WATER; CT;
D O I
10.1109/TUFFC.2021.3070696
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
As being radiation-free, portable, and capable of repetitive use, ultrasonography is playing an important role in diagnosing and evaluating the COVID-19 Pneumonia (PN) in this epidemic. By virtue of lung ultrasound scores (LUSS), lung ultrasound (LUS) was used to estimate the excessive lung fluid that is an important clinical manifestation of COVID-19 PN, with high sensitivity and specificity. However, as a qualitative method, LUSS suffered from large interobserver variations and requirement for experienced clinicians. Considering this limitation, we developed a quantitative and automatic lung ultrasound scoring system for evaluating the COVID-19 PN. A total of 1527 ultrasound images prospectively collected from 31 COVID-19 PN patients with different clinical conditions were evaluated and scored with LUSS by experienced clinicians. All images were processed via a series of computer-aided analysis, including curve-to-linear conversion, pleural line detection, region-of-interest (ROI) selection, and feature extraction. A collection of 28 features extracted from the ROI was specifically defined for mimicking the LUSS. Multilayer fully connected neural networks, support vector machines, and decision trees were developed for scoring LUS images using the fivefold cross validation. The model with 128 x 256 two fully connected layers gave the best accuracy of 87%. It is concluded that the proposed method could assess the ultrasound images by assigning LUSS automatically with high accuracy, potentially applicable to the clinics.
引用
收藏
页码:2507 / 2515
页数:9
相关论文
共 38 条
[1]   Inter-Rater Reliability of Quantifying Pleural B-Lines Using Multiple Counting Methods [J].
Anderson, Kenton L. ;
Fields, J. Matthew ;
Panebianco, Nova L. ;
Jenq, Katherine Y. ;
Marin, Jennifer ;
Dean, Anthony J. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2013, 32 (01) :115-120
[2]   Automated Lung Ultrasound B-Line Assessment Using a Deep Learning Algorithm [J].
Baloescu, Cristiana ;
Toporek, Grzegorz ;
Kim, Seungsoo ;
McNamara, Katelyn ;
Liu, Rachel ;
Shaw, Melissa M. ;
McNamara, Robert L. ;
Raju, Balasundar I. ;
Moore, Christopher L. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (11) :2312-2320
[3]   Automated B-Line Scoring on Thoracic Sonography [J].
Brattain, Laura J. ;
Telfer, Brian A. ;
Liteplo, Andrew S. ;
Noble, Vicki E. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2013, 32 (12) :2185-2190
[4]   Quantitative lung ultrasonography: a putative new algorithm for automatic detection and quantification of B-lines [J].
Brusasco, Claudia ;
Santori, Gregorio ;
Bruzzo, Elisa ;
Tro, Rosella ;
Robba, Chiara ;
Tavazzi, Guido ;
Guarracino, Fabio ;
Forfori, Francesco ;
Boccacci, Patrizia ;
Corradi, Francesco .
CRITICAL CARE, 2019, 23 (01)
[5]   Automatic Pleural Line Extraction and COVID-19 Scoring From Lung Ultrasound Data [J].
Carrer, Leonardo ;
Donini, Elena ;
Marinelli, Daniele ;
Zanetti, Massimo ;
Mento, Federico ;
Torri, Elena ;
Smargiassi, Andrea ;
Inchingolo, Riccardo ;
Soldati, Gino ;
Demi, Libertario ;
Bovolo, Francesca ;
Bruzzone, Lorenzo .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (11) :2207-2217
[6]   Automated Pleural Line Detection Based on Radon Transform Using Ultrasound [J].
Chen, Jiangang ;
Li, Jiawei ;
He, Chao ;
Li, Wenfang ;
Li, Qingli .
ULTRASONIC IMAGING, 2021, 43 (01) :19-28
[7]   Assessment of Interstitial Lung Disease Using Lung Ultrasound Surface Wave Elastography A Novel Technique With Clinicoradiologic Correlates [J].
Clay, Ryan ;
Bartholmai, Brian J. ;
Zhou, Boran ;
Karwoski, Ronald ;
Peikert, Tobias ;
Osborn, Thomas ;
Rajagopalan, Srinivasan ;
Kalra, Sanjay ;
Zhang, Xiaoming .
JOURNAL OF THORACIC IMAGING, 2019, 34 (05) :313-319
[8]   Lung ultrasound and B-lines quantification inaccuracy: B sure to have the right solution [J].
Corradi, F. ;
Via, G. ;
Forfori, F. ;
Brusasco, C. ;
Tavazzi, G. .
INTENSIVE CARE MEDICINE, 2020, 46 (05) :1081-1083
[9]   Computer-Aided Quantitative Ultrasonography for Detection of Pulmonary Edema in Mechanically Ventilated Cardiac Surgery Patients [J].
Corradi, Francesco ;
Brusasco, Claudia ;
Vezzani, Antonella ;
Santori, Gregorio ;
Manca, Tullio ;
Ball, Lorenzo ;
Nicolini, Francesco ;
Gherli, Tiziano ;
Brusasco, Vito .
CHEST, 2016, 150 (03) :640-651
[10]   Assessment of extravascular lung water by quantitative ultrasound and CT in isolated bovine lung [J].
Corradi, Francesco ;
Ball, Lorenzo ;
Brusasco, Claudia ;
Ricci, Anna Maria ;
Baroffio, Michele ;
Bovio, Giulio ;
Pelosi, Paolo ;
Brusasco, Vito .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 187 (03) :244-249