Assessment of tricuspid valve by two- and three-dimensional echocardiography with special reference to percutaneous repair and prosthetic valve implantation procedures

被引:4
|
作者
Murray, Christopher S. G. [1 ]
Salama, Ahmed Y. [2 ]
Akdogan, Raziye E. [2 ]
Harb, Serge [3 ]
Nahar, Tamanna [4 ]
Nanda, Navin C. [2 ]
机构
[1] Columbia Univ, Dept Internal Med, Harlem Hosp Ctr, New York, NY USA
[2] Univ Alabama Birmingham, Dept Med, Div Cardiovasc Dis, Birmingham, AL 35294 USA
[3] Cleveland Clin, Inst Heart & Vasc, Dept Cardiovasc Med, Sect Cardiovasc Imaging, Cleveland, OH 44106 USA
[4] Columbia Univ, Dept Internal Med, Harlem Hosp Ctr, Sect Cardiol, New York, NY USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2018年 / 35卷 / 09期
关键词
echocardiography; three-dimensional echocardiography; transcatheter tricuspid valve repair; transcatheter tricuspid valve-in-valve; tricuspid regurgitation; tricuspid valve; two-dimensional echocardiography; EUROPEAN ASSOCIATION; REGURGITATION LATE; INCREMENTAL VALUE; AMERICAN SOCIETY; MITRACLIP SYSTEM; REAL-TIME; FOLLOW-UP; SURGERY; MANAGEMENT; ADULTS;
D O I
10.1111/echo.14130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Moderate-to-severe tricuspid regurgitation affects approximately 1.6 million people in the United States. An estimated 8000 patients will undergo tricuspid surgery annually, leaving a large number of patients with this condition untreated. Many of these individuals who are not referred for surgery engender a large unmet clinical need; this may be primarily due to the surgical risk involved. In persons who are categorized as high-risk surgical candidates, percutaneous procedures present a viable alternative. The majority of developmental attention as regards percutaneous approaches has been focused on the aortic and mitral valves recently, but few data are available about the feasibility and efficacy of minimally invasive tricuspid valve treatment. We review the usefulness of two- and three-dimensional echocardiography in the assessment of the tricuspid valve with special reference to recent interest in percutaneous repair and prosthetic valve implantation procedures for severe functional tricuspid regurgitation.
引用
收藏
页码:1419 / 1438
页数:20
相关论文
共 50 条
  • [21] Two-Dimensional Echocardiography Incorrectly Identifies Tricuspid Regurgitation Jet Location Compared to Three-Dimensional Echocardiography in Pre-Operative Assessment of Tricuspid Valve Repair in Hypoplastic Left Heart Syndrome
    Mah, Kandice
    Martin, Billie-Jean
    Alvarez, Silvia
    Laroussi, Nassiba Alami
    Rebeyka, Ivan M.
    Smallhorn, Jeffrey
    Khoo, Nee
    Colen, Timothy
    CIRCULATION, 2016, 134
  • [22] Comparative Accuracy of Two- and Three-Dimensional Transthoracic and Transesophageal Echocardiography in Identifying Mitral Valve Pathology in Patients Undergoing Mitral Valve Repair: Initial Observations
    Ben Zekry, Sagit
    Nagueh, Sherif F.
    Little, Stephen H.
    Quinones, Miguel A.
    McCulloch, Marti L.
    Karanbir, Singh
    Herrera, Elizabeth L.
    Lawrie, Gerald M.
    Zoghbi, William A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (10) : 1079 - 1085
  • [23] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Antonella Moreo
    Elisabetta Lobiati
    Benedetta De Chiara
    Francesco Mauri
    Heart and Vessels, 2007, 22 : 287 - 289
  • [24] Assessment of mitral prosthetic valve thrombosis by live three-dimensional echocardiography: comparison with transesophageal echocardiography
    Moreo, Antonella
    Lobiati, Elisabetta
    De Chiara, Benedetta
    Mauri, Francesco
    HEART AND VESSELS, 2007, 22 (04) : 287 - 289
  • [25] Congenital Tricuspid Valve Blood Cyst: Imaging with Three-Dimensional Contrast Echocardiography
    Grapsa, Julia
    Cheung, Wing-See
    Dawson, David
    Nihoyannopoulos, Petros
    HELLENIC JOURNAL OF CARDIOLOGY, 2011, 52 (03) : 278 - 280
  • [26] Tricuspid valve geometry in patients with functional tricuspid regurgitation: A three-dimensional echocardiographic study
    Karamali, Fatemeh
    Hosseini, Saeid
    Shojaeifard, Maryam
    Mohammadi, Khadijeh
    Kaviani, Raheleh
    Rezaei, Yousef
    Samiei, Niloufar
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (06): : 867 - 875
  • [27] The Advantages of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Assessment of Tricuspid Valve Infective Endocarditis
    Sungur, Aylin
    Hsiung, Ming C.
    Quiroz, Luis D. Meggo
    Oez, Tugba Kemaloglu
    Asaad, Ayman Haj
    Joshi, Deepak
    Doenmez, Cevdet
    Guevenc, Tolga S.
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (10): : 1293 - 1309
  • [28] Utilization of Two- and Three-Dimensional Transesophageal Echocardiography in Successfully Guiding Transcatheter Mitral Valve in Bioprosthetic Mitral Valve/Mitral Ring Implantation without Complications in Patients with Thrombus in Left Atrium/Left Atrial Appendage
    Elmarzouky, Zeyad M.
    Hsiung, Ming-Chon
    Darwish, Amr
    Dulal, Subash
    Maturi, Bhanu
    Yin, Wei-Hsian
    Lee, Yung-Tsai
    Tsao, Tien-Ping
    Wei, Jeng
    Nanda, Navin C.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)
  • [29] Three-Dimensional Echocardiography in the Assessment of Congenital Mitral Valve Disease
    Kutty, Shelby
    Colen, Timothy M.
    Smallhorn, Jeffrey F.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (02) : 142 - 154
  • [30] Three-Dimensional Echocardiography in Paravalvular Aortic Regurgitation Assessment after Transcatheter Aortic Valve Implantation
    Goncalves, Alexandra
    Almeria, Carlos
    Marcos-Alberca, Pedro
    Feltes, Gisela
    Hernandez-Antolin, Rosana
    Rodriguez, Enrique
    Silva Cardoso, Jose C.
    Macaya, Carlos
    Luis Zamorano, Jose
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 47 - 55