Assessment of tricuspid valve by two- and three-dimensional echocardiography with special reference to percutaneous repair and prosthetic valve implantation procedures

被引:4
|
作者
Murray, Christopher S. G. [1 ]
Salama, Ahmed Y. [2 ]
Akdogan, Raziye E. [2 ]
Harb, Serge [3 ]
Nahar, Tamanna [4 ]
Nanda, Navin C. [2 ]
机构
[1] Columbia Univ, Dept Internal Med, Harlem Hosp Ctr, New York, NY USA
[2] Univ Alabama Birmingham, Dept Med, Div Cardiovasc Dis, Birmingham, AL 35294 USA
[3] Cleveland Clin, Inst Heart & Vasc, Dept Cardiovasc Med, Sect Cardiovasc Imaging, Cleveland, OH 44106 USA
[4] Columbia Univ, Dept Internal Med, Harlem Hosp Ctr, Sect Cardiol, New York, NY USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2018年 / 35卷 / 09期
关键词
echocardiography; three-dimensional echocardiography; transcatheter tricuspid valve repair; transcatheter tricuspid valve-in-valve; tricuspid regurgitation; tricuspid valve; two-dimensional echocardiography; EUROPEAN ASSOCIATION; REGURGITATION LATE; INCREMENTAL VALUE; AMERICAN SOCIETY; MITRACLIP SYSTEM; REAL-TIME; FOLLOW-UP; SURGERY; MANAGEMENT; ADULTS;
D O I
10.1111/echo.14130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Moderate-to-severe tricuspid regurgitation affects approximately 1.6 million people in the United States. An estimated 8000 patients will undergo tricuspid surgery annually, leaving a large number of patients with this condition untreated. Many of these individuals who are not referred for surgery engender a large unmet clinical need; this may be primarily due to the surgical risk involved. In persons who are categorized as high-risk surgical candidates, percutaneous procedures present a viable alternative. The majority of developmental attention as regards percutaneous approaches has been focused on the aortic and mitral valves recently, but few data are available about the feasibility and efficacy of minimally invasive tricuspid valve treatment. We review the usefulness of two- and three-dimensional echocardiography in the assessment of the tricuspid valve with special reference to recent interest in percutaneous repair and prosthetic valve implantation procedures for severe functional tricuspid regurgitation.
引用
收藏
页码:1419 / 1438
页数:20
相关论文
共 50 条
  • [1] Three-dimensional echocardiography of the tricuspid valve
    Jost, Zachary T.
    Nooli, Nishank P.
    Ali, Ahmed E.
    Jaganathan, Vijayadithyan
    Nanda, Navin C.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [2] Three-Dimensional Echocardiography for Tricuspid Valve Assessment
    Claudia Escabia
    Antoni Bayes-Genis
    Victoria Delgado
    Current Cardiology Reports, 2022, 24 : 1611 - 1618
  • [3] Three-Dimensional Echocardiography for Tricuspid Valve Assessment
    Escabia, Claudia
    Bayes-Genis, Antoni
    Delgado, Victoria
    CURRENT CARDIOLOGY REPORTS, 2022, 24 (11) : 1611 - 1618
  • [4] Incremental Value of the En Face View of the Tricuspid Valve by Two-Dimensional and Three-Dimensional Echocardiography for Accurate Identification of Tricuspid Valve Leaflets
    Stankovic, Ivan
    Daraban, Ana Maria
    Jasaityte, Ruta
    Neskovic, Aleksandar N.
    Claus, Piet
    Voigt, Jens-Uwe
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (04) : 376 - 384
  • [5] Preoperative assessment of mitral valve regurgitation with two- and three-dimensional transesophageal echocardiography
    Meucci, Maria Chiara
    Delgado, Victoria
    CIRUGIA CARDIOVASCULAR, 2022, 29 : S54 - S61
  • [6] Two- and Three-dimensional Transthoracic Echocardiographic Assessment of Tricuspid Valve Prolapse with Mid-to-Late Systolic Tricuspid Regurgitation
    Elsayed, Mahmoud
    Thind, Munveer
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (06): : 1022 - 1025
  • [7] Parachute Tricuspid Valve in a Patient with Atrial Septal Defect Detected by Two- and Three-Dimensional Echocardiography
    Demirkol, Sait
    Balta, Sevket
    Unlu, Murat
    Bozlar, Ugur
    Arslan, Zekeriya
    Karaman, Bulent
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (10): : E255 - E257
  • [8] Understanding tricuspid valve remodelling in atrial fibrillation using three-dimensional echocardiography
    Ortiz-Leon, Xochitl A.
    Posada-Martinez, Edith L.
    Trejo-Paredes, Maria C.
    Ivey-Miranda, Juan B.
    Pereira, Jason
    Crandall, Ian
    DaSilva, Paul
    Bouman, Eileen
    Brooks, Alyssa
    Gerardi, Christine
    Ugonabo, Ifeoma
    Chen, Wanwen
    Houle, Helene
    Akar, Joseph G.
    Lin, Ben A.
    McNamara, Robert L.
    Lombo-Lievano, Bernardo
    Arias-Godinez, Jose A.
    Sugeng, Lissa
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (07) : 747 - 755
  • [9] Acute changes in mitral valve geometry after percutaneous valve repair with MitraClip XTR by three-dimensional echocardiography
    Tusa, Maurizio B.
    Barletta, Marta
    Rubbio, Antonio Popolo
    Travaglio, Nicole
    Saffioti, Silvia
    Granata, Giuseppina
    Mantovani, Valentina
    Stefanini, Elisa
    Corciu, Anca, I
    Testa, Luca
    Bedogni, Francesco
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (11): : 1913 - 1923
  • [10] Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography
    Badano, Luigi P.
    Agricola, Eustachio
    de Isla, Leopoldo Perez
    Gianfagna, Pasquale
    Zamorano, Jose Louis
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (04): : 477 - 484