Intraoperative computed tomography as reliable navigation registration device in 200 cranial procedures

被引:39
作者
Carl, Barbara [1 ,2 ]
Bopp, Miriam [1 ,2 ]
Sass, Benjamin [1 ,2 ]
Nimsky, Christopher [1 ,2 ]
机构
[1] Univ Marburg, Dept Neurosurg, Baldingerstr, D-35033 Marburg, Germany
[2] MCMBB, Marburg, Germany
关键词
Effective radiation dose; Intraoperative imaging; Intraoperative computed tomography; Navigation accuracy; Navigation registration; DOSE-LENGTH PRODUCT; AUTOMATED REGISTRATION; ACCURACY; SURGERY; CT; IMPLANTATION; SCANNER; NEURONAVIGATION; INSTRUMENTATION; IMPLEMENTATION;
D O I
10.1007/s00701-018-3641-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Registration accuracy is a main factor influencing overall navigation accuracy. Standard fiducial- or landmark-based patient registration is user dependent and error-prone. Intraoperative imaging offers the possibility for user-independent patient registration. The aim of this paper is to evaluate our initial experience applying intraoperative computed tomography (CT) for navigation registration in cranial neurosurgery, with a special focus on registration accuracy and effective radiation dose. Methods A total of 200 patients (141 craniotomy, 19 transsphenoidal, and 40 stereotactic burr hole procedures) were investigated by intraoperative CT applying a 32-slice movable CT scanner, which was used for automatic navigation registration. Registration accuracy was measured by at least three skin fiducials that were not part of the registration process. Results Automatic registration resulted in high registration accuracy (mean registration error: 0.93 +/- 0.41 mm). Implementation of low-dose scanning protocols did not impede registration accuracy (registration error applying the full dose head protocol: 0.87 +/- 0.36 mm vs. the low dose sinus protocol 0.72 +/- 0.43 mm) while a reduction of the effective radiation dose by a factor of 8 could be achieved (mean effective radiation dose head protocol: 2.73 mSv vs. sinus protocol: 0.34 mSv). Conclusion Intraoperative CT allows highly reliable navigation registration with low radiation exposure.
引用
收藏
页码:1681 / 1689
页数:9
相关论文
共 37 条
[1]   Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications [J].
Black, PM ;
Moriarty, T ;
Alexander, E ;
Stieg, P ;
Woodard, EJ ;
Gleason, PL ;
Martin, CH ;
Kikinis, R ;
Schwartz, RB ;
Jolesz, FA .
NEUROSURGERY, 1997, 41 (04) :831-842
[2]   Accuracy of Intraoperative Computed Tomography during Deep Brain Stimulation Procedures: Comparison with Postoperative Magnetic Resonance Imaging [J].
Bot, Maarten ;
van den Munckhof, Pepijn ;
Bakay, Roy ;
Stebbins, Glenn ;
Metman, Leo Verhagen .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2017, 95 (03) :183-188
[3]   Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording Clinical article [J].
Burchiel, Kim J. ;
McCartney, Shirley ;
Lee, Albert ;
Raslan, Ahmed M. .
JOURNAL OF NEUROSURGERY, 2013, 119 (02) :301-306
[4]   A mobile computed tomographic scanner with intraoperative and intensive care unit applications [J].
Butler, WE ;
Piaggio, CM ;
Constantinou, C ;
Niklason, L ;
Gonzalez, RG ;
Cosgrove, GR ;
Zervas, NT .
NEUROSURGERY, 1998, 42 (06) :1304-1310
[5]   Preoperative 3-Dimensional Angiography Data and Intraoperative Real-Time Vascular Data Integrated in Microscope-Based Navigation by Automatic Patient Registration Applying Intraoperative Computed Tomography [J].
Carl, Barbara ;
Bopp, Miriam ;
Chehab, Somar ;
Bien, Siegfried ;
Nimsky, Christopher .
WORLD NEUROSURGERY, 2018, 113 :E414-E425
[6]   Low-grade Glioma Surgery in Intraoperative Magnetic Resonance Imaging: Results of a Multicenter Retrospective Assessment of the German Study Group for Intraoperative Magnetic Resonance Imaging [J].
Coburger, Jan ;
Merkel, Andreas ;
Scherer, Moritz ;
Schwartz, Felix ;
Gessler, Florian ;
Roder, Constantin ;
Pala, Andrej ;
Koenig, Ralph ;
Bullinger, Lars ;
Nagel, Gabriele ;
Jungk, Christine ;
Bisdas, Sotirios ;
Nabavi, Arya ;
Ganslandt, Oliver ;
Seifert, Volker ;
Tatagiba, Marcos ;
Senft, Christian ;
Mehdorn, Maximilian ;
Unterberg, Andreas W. ;
Roessler, Karl ;
Wirtz, Christian Rainer .
NEUROSURGERY, 2016, 78 (06) :775-785
[7]   Spinal navigation for posterior instrumentation of C1-2 instability using a mobile intraoperative CT scanner [J].
Czabanka, Marcus ;
Haemmerli, Julien ;
Hecht, Nils ;
Foehre, Bettina ;
Arden, Klaus ;
Liebig, Thomas ;
Woitzik, Johannes ;
Vajkoczy, Peter .
JOURNAL OF NEUROSURGERY-SPINE, 2017, 27 (03) :268-275
[8]   Intraoperative computed tomography registration and electromagnetic neuronavigation for transsphenoidal pituitary surgery: accuracy and time effectiveness Clinical article [J].
Eboli, Paula ;
Shafa, Bob ;
Mayberg, Marc .
JOURNAL OF NEUROSURGERY, 2011, 114 (02) :329-335
[9]   Intraoperative computed tomography and automated registration for image-guided cranial surgery [J].
Eggers, G. ;
Kress, B. ;
Rohde, S. ;
Muehling, J. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (01) :28-33
[10]   Fully automated registration of intraoperative computed tomography image data for image-guided craniofacial surgery [J].
Eggers, Georg ;
Kress, Bodo ;
Muehling, Joachim .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (08) :1754-1760