Characterization of CVD diamond films as radiation detectors for dosimetric applications

被引:0
作者
Bruzzi, M [1 ]
Bucciolini, M [1 ]
Cirrone, GAP [1 ]
Cuttone, G [1 ]
Guasti, A [1 ]
Mazzocchi, S [1 ]
Pirollo, S [1 ]
Sabini, MG [1 ]
Sciortino, S [1 ]
机构
[1] Univ Florence, Dipartimento Energet, I-50139 Florence, Italy
来源
1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3 | 1999年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The possibilitiy of using CVD diamond films as dosimeters in radiotherapy applications has been tested in both off-line and on-line configurations. The ThermoLuminescent and Thermally Stimulated Current responses after 20MeV electron and 22MeV proton irradiation have been studied as a function of the dose up to 10 Gy. CVD Diamond compares favourably with standard off-line LiF dosimeters. In on-line configuration, detector-grade high-purity CVD diamond shows a sensitivity almost four order of magnitude higher than that of ionisation chambers.
引用
收藏
页码:121 / 124
页数:4
相关论文
共 50 条
  • [21] Homogeneity of CVD diamond detectors in tracking applications
    Manfredotti, C
    Fizzotti, F
    Giudice, L
    Paolini, C
    Vittone, E
    Lu, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 187 (04) : 566 - 578
  • [22] Characterization of 14 MeV neutron detectors made with polycrystalline CVD diamond films
    Pillon, M.
    Angelone, M.
    Lattanzi, D.
    Marinelli, M.
    Milani, E.
    Tucciarone, A.
    Verona-Rinati, G.
    21ST IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING - SOFE 05, 2006, : 521 - 524
  • [23] CVD DIAMOND FILMS FOR RADIATION DETECTION
    FOULON, F
    POCHET, T
    GHEERAERT, E
    DENEUVILLE, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 927 - 932
  • [24] Effects of the film microstructures on CVD diamond radiation detectors
    Zhang, ML
    Xia, YB
    Wang, LJ
    Gu, BB
    JOURNAL OF CRYSTAL GROWTH, 2005, 277 (1-4) : 382 - 387
  • [25] Radiation tolerance of CVD diamond detectors for pions and protons
    Adam, W
    Berdermann, E
    Bergonzo, P
    Bertuccio, G
    Bogani, F
    Borchi, E
    Brambilla, A
    Bruzzi, M
    Colledani, C
    Conway, J
    D'Angelo, P
    Dabrowski, W
    Delpierre, P
    Deneuville, A
    Dulinski, W
    van Eijk, B
    Fallou, A
    Fizzotti, F
    Foulon, F
    Friedl, M
    Gan, KK
    Gheeraert, E
    Hallewell, G
    Han, S
    Hartjes, F
    Hrubec, J
    Husson, D
    Kagan, H
    Kania, D
    Kaplon, J
    Kass, R
    Koeth, T
    Krammer, M
    Logiudice, A
    Lu, R
    Mac Lynne, L
    Manfredotti, C
    Meier, D
    Mishina, M
    Moroni, L
    Noomen, J
    Oh, A
    Pan, LS
    Pernicka, M
    Peitz, A
    Perera, L
    Pirollo, S
    Procario, M
    Riester, JL
    Roe, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03) : 686 - 693
  • [26] CVD DIAMOND FILMS FOR ELECTRONIC APPLICATIONS
    IYER, SB
    METALS MATERIALS AND PROCESSES, 1994, 5 (04): : 259 - 268
  • [27] Applications of conformal CVD diamond films
    Rotter, S
    ISRAEL JOURNAL OF CHEMISTRY, 1998, 38 (1-2) : 135 - 140
  • [28] Operating parameters of CVD diamond detectors for radiation dosimetry
    Betzel, G. T.
    Lansley, S. P.
    Baluti, F.
    Reinisch, L.
    Meyer, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 614 (01) : 130 - 136
  • [29] Present limitations of CVD diamond detectors for IMRT applications
    De Angelis, C.
    Casati, M.
    Bruzzi, M.
    Onori, S.
    Bucciolini, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (01) : 195 - 203
  • [30] CVD diamond detectors
    Manfredotti, C
    Polesello, P
    Truccato, M
    Vittone, E
    Lo Giudice, A
    Fizzotti, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (01) : 96 - 99