Chairside virtual patient protocol. Part 2: Management of multiple face scans and alignment predictability

被引:19
作者
Raffone, Carlo [1 ]
Gianfreda, Francesco [2 ]
Pompeo, Mario Giulio [1 ]
Antonacci, Donato
Bollero, Patrizio [3 ]
Canullo, Luigi [1 ]
机构
[1] Via Nizza 46, I-00198 Rome, Italy
[2] Univ Roma Tor Vergata, Dept Ind Engn, I-00133 Rome, Italy
[3] Univ Roma Tor Vergata, Dept Syst Med, I-00133 Rome, Italy
关键词
Digital matching; Full digital workflow; Facescan; Superimposition; Alignment; Virtual patient; WORKFLOW; SMILE;
D O I
10.1016/j.jdent.2022.104123
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Face scans are currently used in dentistry to obtain a virtual patient. Find stable and repeatable references for their matching is a fundamental step. Aim of this study is to evaluate matching reliability of multiple face scans using frontal adhesives references. Null hypothesis was that no significant discrepancy could be detected between the references position analyzed both with surface analysis and linear analysis. Materials and methods: Nine patients were enrolled for this study and nine soft tissue adhesives landmarks (APLI Paper S.A.U, 4 mm o) placed, equally distributed, on the forehead and glabella. Patients were digitally scanned with a portable scanner (iPad Pro 3rd Gen. Apple Store, Cupertino, CA, USA) using the software Bellus3D (Inc. Campbell, CA, USA) in maximum intercuspation, with a full smile and with a scan reference device. After the scan procedure, a high-definition polygon file format (.ply) was exported, and linear measurements were collected with MeshLab (MeshLab; MeshLab). In order to further evaluate reference accuracy, a surface analysis was performed using a CAD software (GOM inspect, GOM). 3D deviations were calculated as root mean square. Statistical analysis was performed used two repeated-measures ANOVAs. Results: Results showed non-significant differences both for linear measurements (p=.22) and surface analysis (p=.58). Frontal references showed to be clinical reliable landmarks for use during face scans alignment, even with different facial expressions. Conclusion: The proposed technique seems to be suitable for the clinical use when superimposition of several face scans is required. Clinical significance: This study showed the clinical reliability of face scans matching method using adhesives references. These references are cheap and easy to use, allowing for a rapid registration of the patient anatomy.
引用
收藏
页数:6
相关论文
共 35 条
[1]   The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study [J].
Amornvit, Pokpong ;
Sanohkan, Sasiwimol .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
[2]   EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS [J].
AUNG, SC ;
NGIM, RCK ;
LEE, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08) :551-558
[3]   Benefits of Digital Smile Design (DSD) in the conception of a complex orthodontic treatment plan: A case report-proof of concept [J].
Charavet, Carole ;
Bernard, Jean-Claude ;
Gaillard, Cyril ;
Le Gall, Michel .
INTERNATIONAL ORTHODONTICS, 2019, 17 (03) :573-579
[4]   Dynamic Documentation of the Smile and the 2D/3D Digital Smile Design Process [J].
Coachman, Christian ;
Calamita, Marcelo Alexandre ;
Sesma, Newton .
INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2017, 37 (02) :183-+
[5]   DIGITALLY ENHANCED ESTHETIC DENTISTRY - FROM TREATMENT PLANNING TO QUALITY CONTROL [J].
Coachman, Christian ;
Paravina, Rade D. .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2016, 28 :S3-S4
[6]   A comparison between stereophotogrammetry and smartphone structured light technology for three-dimensional face scanning [J].
D'Ettorre, Giorgio ;
Farronato, Marco ;
Candida, Ettore ;
Quinzi, Vincenzo ;
Grippaudo, Cristina .
ANGLE ORTHODONTIST, 2022, 92 (03) :358-363
[7]   Facial Scanner Accuracy with Different Superimposition Methods: An In Vivo Study [J].
da Silva Marques, Duarte Nuno ;
Aparicio Aguiar Alves, Rita Vanessa ;
Marques Pinto, Ricardo Jorge ;
Bartolo Carames, Joao Rodrigo ;
de Oliveira Francisco, Helena Cristina ;
Mendez Carames, Joao Manuel .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (05) :578-584
[8]   A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally invasive approach [J].
Ferrando-Cascales, Alvaro ;
Astudillo-Rubio, Daniela ;
Pascual-Moscardo, Agustin ;
Delgado-Gaete, Andres .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (04) :537-547
[9]   Are Portable Stereophotogrammetric Devices Reliable in Facial Imaging? A Validation Study of VECTRA H1 Device [J].
Gibelli, Daniele ;
Pucciarelli, Valentina ;
Cappella, Annalisa ;
Dolci, Claudia ;
Sforza, Chiarella .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (08) :1772-1784
[10]   A digital approach integrating facial scanning in a CAD-CAM workflow for complete-mouth implant-supported rehabilitation of patients with edentulism: A pilot clinical study [J].
Hassan, Bassam ;
Gonzalez, Beatriz Gimenez ;
Tahmaseb, Ali ;
Greven, Marcus ;
Wismeijer, Daniel .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) :486-492