摘要
Objectives. To suggest a novel algorithm based on individually determined proportionality constants to improve the accuracy of noninvasively calculated residual urine volume using ultrasound bladder images. Methods. The residual urine volume of 116 subjects was calculated from ultrasound images obtained using a conventional two-dimensional ultrasound device at two institutions. The proposed method uses individually determined proportionality constants for specific bladder shapes. The corresponding true residual volumes were determined by measuring the catheterized volume. The accuracy of our method was confirmed by comparing the mean and standard deviation of the fractional absolute error (FAE) versus true volume with values obtained using other methods, which rely on fixed constants. Results. The calculated residual bladder volume of 1 16 patients correlated significantly (r = 0.94, P <0.001) and the differences from the true values were not statistically significant (P = 0.42). The mean FAE was 0.17 +/- 0. 10. Subgroups divided by sex, postvoid residual urine volume (over and under 150 mL, and institution produced different results (mean FAE for men 0. 15 +/- 0.1 1 and for women 0.18 +/- 0.12; mean FAE for greater than 150 mL, 0.16 +/- 0.11 and for less than 150 mL, 0.17 +/- 0.14; mean FAE for Seoul National University Hospital 0.15 +/- 0.10 and for Seoul National University Bundang Hospital 0.18 +/- 0.18). Our method provided better accuracy than other known formulas using a conventional two-dimensional ultrasound scanner. The latter multiply the product of the sagittal height and depth and transverse width by a fixed coefficient. Conclusions. Our method, based on individually determined proportionality constants, improved the accuracy of residual bladder volume determinations. The proposed algorithm can easily be implemented on a personal computer connected to a conventional ultrasound imaging unit. (C) 2004 Elsevier Inc.
引用
收藏
页码:887 / 891
页数:5
相关论文
共 18 条
[1]   The accuracy of portable abdominal ultrasound equipment in measuring postvoid residual volume [J].
Alnaif B. ;
Drutz H.P. .
International Urogynecology Journal, 1999, 10 (4) :215-218
[2]   ULTRASOUND ASSESSMENT OF RESIDUAL URINE - A QUANTITATIVE METHOD [J].
BEACOCK, CJM ;
ROBERTS, EE ;
REES, RWM ;
BUCK, AC .
BRITISH JOURNAL OF UROLOGY, 1985, 57 (04) :410-413
[3]   THE ACCURACY OF PORTABLE ULTRASOUND SCANNING IN THE MEASUREMENT OF RESIDUAL URINE VOLUME [J].
COOMBES, GM ;
MILLARD, RJ .
JOURNAL OF UROLOGY, 1994, 152 (06) :2083-2085
[4]   ACCURACY AND REPEATABILITY OF BLADDER VOLUME MEASUREMENT USING ULTRASONIC-IMAGING [J].
GRIFFITHS, CJ ;
MURRAY, A ;
RAMSDEN, PD .
JOURNAL OF UROLOGY, 1986, 136 (04) :808-812
[5]   THE ESTIMATION OF BLADDER VOLUME BY SONOCYSTOGRAPHY [J].
HAKENBERG, OW ;
RYALL, RL ;
LANGLOIS, SL ;
MARSHALL, VR .
JOURNAL OF UROLOGY, 1983, 130 (02) :249-251
[6]   REAL-TIME ULTRASOUND MEASUREMENT OF BLADDER VOLUME - A COMPARATIVE-STUDY OF 3 METHODS [J].
HARTNELL, GG ;
KIELY, EA ;
WILLIAMS, G ;
GIBSON, RN .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (719) :1063-1065
[7]   TRANS-VAGINAL ULTRASOUND IN THE ASSESSMENT OF BLADDER VOLUMES IN WOMEN - PRELIMINARY-REPORT [J].
HAYLEN, BT ;
FRAZER, MI ;
SUTHERST, JR ;
WEST, CR .
BRITISH JOURNAL OF UROLOGY, 1989, 63 (02) :149-151
[8]   ULTRASONIC STUDIES OF BLADDER [J].
HOLMES, JH .
JOURNAL OF UROLOGY, 1967, 97 (04) :654-&
[9]   BLADDER VOLUME DETERMINATION USING A DEDICATED, PORTABLE ULTRASOUND SCANNER [J].
IRETON, RC ;
KRIEGER, JN ;
CARDENAS, DD ;
WILLIAMSBURDEN, B ;
KELLY, E ;
SOUCI, T ;
CHAPMAN, WH .
JOURNAL OF UROLOGY, 1990, 143 (05) :909-911
[10]  
Jain AK., 1989, Fundamentals of Digital Image Processing