Target analysis of tert-butyldimethylsilyl derivatives of nerve agent hydrolysis products by selectable one-dimensional or two-dimensional gas chromatography-mass spectrometry

被引:10
作者
Seto, Yasuo [1 ]
Tachikawa, Masumi [1 ]
Kanamori-Kataoka, Mieko [1 ]
Sasamoto, Kikuo [2 ]
Ochiai, Nobuo [2 ]
机构
[1] Natl Res Inst Police Sci, Kashiwa, Chiba 2770882, Japan
[2] Gerstel KK, Meguro Ku, 1-3-1 Nakane, Tokyo 1520031, Japan
关键词
Heart-cut; Gas chromatography-mass spectrometry; Nerve agent; Hydrolysis product; tert-Butyldimethylsilylation; Matrix interference; CHEMICAL WARFARE AGENTS; SOLID-PHASE EXTRACTION; DEGRADATION-PRODUCTS; HUMAN BUTYRYLCHOLINESTERASE; RETROSPECTIVE DETECTION; QUANTITATIVE-ANALYSIS; EXPOSURE; PRETREATMENT; DERIVATIZATION; VERIFICATION;
D O I
10.1016/j.chroma.2017.04.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A target analysis method for the sensitive and discriminative determination of the nerve agent hydrolysis products alkyl methylphosphonic acids as their tert-butyldimethylsilyl (TBDMS) derivatives was developed using a combination of selectable one- and two-dimensional (D-1/D-2) GC-MS, and applied to the analysis of samples with significant interfering matrices. After sample drying, the alkylmethylphosphonic acids and methylphosphonic acid (MPA) were converted to TBDMS derivatives by addition of N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide with heating, and subjected to 1D/2D GC-MS. The apparatus consisted of an initial low thermal mass DB-5 column and a second DB-17 column together with an electron ionization quadrupole mass spectrometer, offering simple and flexible switching between one and two-dimensional GC-MS analysis in a single GC-MS system. Using D-1/D-2 GC-MS, analytes that do not co-elute with matrix components can be separated using D-1 GC mode alone. Only those parts of the chromatogram that are negatively affected by the co-elution of matrix components need to be transferred and separated with D-2 GC. Quantitation can be performed by a combination of both separations and mass spectrometric detection. The TBDMS derivatives of ethyl-, isopropyl-, isobutyl-, pinacolyl-, and cyclohexyl-MPA (cHMPA) and MPA itself were well separated within 3 min and determined in 1D GC-MS mode with detection limits of around 10 ng/ml of reaction mixture (except for the cHMPA derivative, whose mass spectrum contained noisy background peaks). In D-2-GC-MS mode, where each 0.04 min elution window from the 1D GC was subjected to heart-cut (H/C) and transferred to the second column after back-flushing the first column, the peak for the cHMPA TBDMS derivative was isolated and afforded a clean mass spectrum within 6 min. The recoveries of all the derivatives on 2D GC from 1D GC were estimated to be over 66%, and the detection limits were around 10 ng/ml of reaction mixture. In the presence of urine extract, the target compounds were not detected as separated peaks in 1D GC-MS mode (except for isobutyl-MPA), and quantification based on extracted ion monitoring could not be achieved. However, D-2 GC-MS of the H/C fractions of the target derivatives gave single peaks with well-defined mass spectra, and the recoveries of the derivatives were over 70% except for cHMPA (31% at 1.25 mu g/ml). Phosphonic acids could be detected at less than 60 ng/ml. Sulfuric acid and phosphoric acid also negatively affected the determination of alkyl methylphosphonic acid TBDMS derivatives in D-1 GC-MS, and the MPA-TBDMS-derivative peak was completely obscured by the large sulfuric-acid-derivative peak. However, under I D-1/D-2 GC-MS conditions, baseline separation of the MPA derivative and sulfuric acid derivative was achieved, enabling highly sensitive MPA detection at 20 ng/ml. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 44 条
[11]   Effect of cation-exchange pretreatment of aqueous soil extracts on the gas chromatographic mass spectrometric determination of nerve agent hydrolysis products after tert.-butyldimethylsilylation [J].
Kataoka, M ;
Tsunoda, N ;
Ohta, H ;
Tsuge, K ;
Takesako, H ;
Seto, Y .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (02) :211-221
[12]   Efficiency of pretreatment of aqueous samples using a macroporous strong anion-exchange resin on the determination of nerve gas hydrolysis products by gas chromatography-mass spectrometry after tert.-butyldimethylsilylation [J].
Kataoka, M ;
Tsuge, K ;
Seto, Y .
JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (02) :295-304
[13]   Discriminative determination of alkyl methylphosphonates and methylphosphonate in blood plasma and urine by gas chromatography-mass spectrometry after tert.-butyldimethylsilylation [J].
Kataoka, M ;
Seto, Y .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (01) :123-132
[14]   Effect of pedological characteristics on aqueous soil extraction recovery and tert-butyldimethylsilylation yield for gas chromatography -: Mass spectrometry of nerve gas hydrolysis products from soils [J].
Kataoka, M ;
Tsuge, K ;
Takesako, H ;
Hamazaki, T ;
Seto, Y .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (09) :1823-1829
[15]  
KATAOKA M, 2002, JPN J ASS SCI TECHNO, V6, P117
[16]   Chromatography and mass spectrometry of chemical warfare agents, toxins and related compounds: state of the art and future prospects [J].
Kientz, CE .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :1-23
[17]   Continuum in MDGC Technology: From Classical Multidimensional to Comprehensive Two-Dimensional Gas Chromatography [J].
Kulsing, Chadin ;
Nolvachai, Yada ;
Rawson, Paul ;
Evans, David J. ;
Marriott, Philip J. .
ANALYTICAL CHEMISTRY, 2016, 88 (07) :3529-3538
[18]   Organophosphorus pesticide and ester analysis by using comprehensive two-dimensional gas chromatography with flame photometric detection [J].
Liu, Xiangping ;
Li, Dengkun ;
Li, Jiequan ;
Rose, Gavin ;
Marriott, Philip J. .
JOURNAL OF HAZARDOUS MATERIALS, 2013, 263 :761-767
[19]   Low thermal mass gas chromatography: Principles and applications [J].
Luong, J ;
Gras, R ;
Mustacich, R ;
Cortes, H .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2006, 44 (05) :253-+
[20]   Analysis of gin essential oil mixtures by multidimensional and one-dimensional gas chromatography/mass spectrometry with spectral deconvolution [J].
Mac Namara, Kevin ;
Howell, Jessalin ;
Huang, Yongli ;
Robbat, Albert, Jr. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) :281-290