Dual-Energy CT, Virtual Non-Calcium Bone Marrow Imaging of the Spine: An AI-Assisted, Volumetric Evaluation of a Reference Cohort with 500 CT Scans

被引:5
|
作者
Fervers, Philipp [1 ,2 ]
Fervers, Florian [3 ]
Weisthoff, Mathilda [1 ,2 ]
Rinneburger, Miriam [1 ,2 ]
Zopfs, David [1 ,2 ]
Reimer, Robert Peter [1 ,2 ]
Pahn, Gregor [4 ]
Kottlors, Jonathan [1 ,2 ]
Maintz, David [1 ,2 ]
Lennartz, Simon [1 ,2 ]
Persigehl, Thorsten [1 ,2 ]
Hokamp, Nils Grosse [1 ,2 ]
机构
[1] Univ Cologne, Fac Med, Dept Diagnost & Intervent Radiol, D-50937 Cologne, Germany
[2] Univ Cologne, Univ Hosp Cologne, D-50937 Cologne, Germany
[3] Fraunhofer Inst Optron Syst Technol & Image Explo, D-76131 Karlsruhe, Germany
[4] Philips CT Clin Sci, D-22335 Hamburg, Germany
关键词
bone marrow; spine; tomography; X-ray computed; artificial intelligence; SPECTRAL COMPUTED-TOMOGRAPHY; PERCENTILES; METASTASES; SEPARATION; ACCURACY; CHILDREN; OBESITY; RISK;
D O I
10.3390/diagnostics12030671
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Virtual non-calcium (VNCa) images from dual-energy computed tomography (DECT) have shown high potential to diagnose bone marrow disease of the spine, which is frequently disguised by dense trabecular bone on conventional CT. In this study, we aimed to define reference values for VNCa bone marrow images of the spine in a large-scale cohort of healthy individuals. DECT was performed after resection of a malignant skin tumor without evidence of metastatic disease. Image analysis was fully automated and did not require specific user interaction. The thoracolumbar spine was segmented by a pretrained convolutional neuronal network. Volumetric VNCa data of the spine's bone marrow space were processed using the maximum, medium, and low calcium suppression indices. Histograms of VNCa attenuation were created for each exam and suppression setting. We included 500 exams of 168 individuals (88 female, patient age 61.0 +/- 15.9). A total of 8298 vertebrae were segmented. The attenuation histograms' overlap of two consecutive exams, as a measure for intraindividual consistency, yielded a median of 0.93 (IQR: 0.88-0.96). As our main result, we provide the age- and sex-specific bone marrow attenuation profiles of a large-scale cohort of individuals with healthy trabecular bone structure as a reference for future studies. We conclude that artificial-intelligence-supported, fully automated volumetric assessment is an intraindividually robust method to image the spine's bone marrow using VNCa data from DECT.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Optimising dual-energy CT scan parameters for virtual non-calcium imaging of the bone marrow: a phantom study
    Mueller, Felix C.
    Borgesen, Henrik
    Gosvig, Kasper
    Rodell, Anders
    Booz, Christian
    Schmidt, Bernhard
    Krauss, Bernhard
    Boesen, Mikael
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01)
  • [2] Optimising dual-energy CT scan parameters for virtual non-calcium imaging of the bone marrow: a phantom study
    Felix C. Müller
    Henrik Børgesen
    Kasper Gosvig
    Anders Rodell
    Christian Booz
    Bernhard Schmidt
    Bernhard Krauss
    Mikael Boesen
    European Radiology Experimental, 3
  • [3] Virtual non-calcium dual-energy CT: clinical applications
    Tommaso D’Angelo
    Moritz H. Albrecht
    Danilo Caudo
    Silvio Mazziotti
    Thomas J. Vogl
    Julian L. Wichmann
    Simon Martin
    Ibrahim Yel
    Giorgio Ascenti
    Vitali Koch
    Giuseppe Cicero
    Alfredo Blandino
    Christian Booz
    European Radiology Experimental, 5
  • [4] Virtual non-calcium dual-energy CT: clinical applications
    D'Angelo, Tommaso
    Albrecht, Moritz H.
    Caudo, Danilo
    Mazziotti, Silvio
    Vogl, Thomas J.
    Wichmann, Julian L.
    Martin, Simon
    Yel, Ibrahim
    Ascenti, Giorgio
    Koch, Vitali
    Cicero, Giuseppe
    Blandino, Alfredo
    Booz, Christian
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [5] Detection of bone marrow oedema in knee joints using a dual-energy CT virtual non-calcium technique
    Wang, M-Y
    Zhang, X-Y
    Xu, L.
    Feng, Y.
    Xu, Y-C
    Qi, L.
    Zou, Y-F
    CLINICAL RADIOLOGY, 2019, 74 (10) : 815.e1 - 815.e7
  • [6] Scaphoid fracture: Bone marrow edema detected with dual-energy CT virtual non-calcium images and confirmed with MRI
    Dareez, Nazeer M.
    Dahlslett, Kristine H.
    Engesland, Eirin
    Lindland, Elisabeth S.
    SKELETAL RADIOLOGY, 2017, 46 (12) : 1753 - 1756
  • [7] Scaphoid fracture: Bone marrow edema detected with dual-energy CT virtual non-calcium images and confirmed with MRI
    Nazeer M. Dareez
    Kristine H. Dahlslett
    Eirin Engesland
    Elisabeth S. Lindland
    Skeletal Radiology, 2017, 46 : 1753 - 1756
  • [8] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Foti, Giovanni
    Beltramello, Alberto
    Catania, Matteo
    Rigotti, Stefano
    Serra, Gerardo
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (06): : 487 - 494
  • [9] Nondisplaced fractures on hip CT: added value of dual-energy CT virtual non-calcium imaging for detection of bone marrow edema using visual and quantitative analyses
    Jang, Seong Won
    Chung, Bo Mi
    Kim, Wan Tae
    Gil, Jea Ryung
    ACTA RADIOLOGICA, 2019, 60 (11) : 1465 - 1473
  • [10] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Giovanni Foti
    Alberto Beltramello
    Matteo Catania
    Stefano Rigotti
    Gerardo Serra
    Giovanni Carbognin