Studies of DC conductor corona in a small corona cage

被引:0
|
作者
Sibilant, GC
Ijumba, NM
Britten, AC
机构
关键词
corona; corona cage; corona current; electric field; high voltage direct current (HVDC); silicon coating; surface gradient;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The complex nature of corona phenomena, combined with the number of factors influencing these effects, make experimental studies indispensable for evaluating the corona performance of transmission lines. Different methods, ranging from tests in laboratory cages to measurements on operational transmission lines, may be used for obtaining the necessary data. This paper gives an introduction to the design of a small corona cage as well as presenting test results obtained from the cage. These tests involved changing the surface conditions of conductors by coating them with silicon, in order to determine their corona performance under the effects of wind. It is concluded that wind in a corona cage does not play a big part in corona loss for a clean conductor. It is recommended that further tests be carried out with a stronger wind source.
引用
收藏
页码:2202 / 2207
页数:6
相关论文
共 50 条
  • [21] Influence of Air Pressure on Positive DC Corona Inception Voltage of Stranded Conductors in the Corona cage
    Meng, Xiaobo
    Bian, Xingming
    Chen, Fenglin
    Yang, Yingjian
    Wang, Liming
    Guan, Zhicheng
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [22] Research on High Altitude Corona Loss Measurement System Based on Small Corona Cage
    Liu Yun-peng
    Ren Lei-jian
    Chen Yong
    Wan Qi-fa
    You Shao-hua
    Chen Weijiang
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 144 - +
  • [23] Corona audible noise measurements in a small indoor corona cage under HVDC voltages
    Lekganyane, M. J.
    Ijumba, N. M.
    Britten, A. C.
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2663 - +
  • [24] AGING EFFECTS OF CONDUCTOR SURFACE CONDITIONS ON DC CORONA CHARACTERISTICS
    SUDA, T
    HIRAYAMA, Y
    SUNAGA, Y
    IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (04) : 1903 - 1912
  • [25] Characteristics of Negative Corona Current Pulses from DC Conductor Parallel with AC Conductor
    Cheng J.
    Li X.
    Zhang J.
    Li Y.
    Liu Y.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (09): : 3343 - 3351
  • [26] Small corona cage for wideband HVac radio noise studies: Rationale and critical design
    Urban, Rodney G.
    Reader, Howard C.
    Holtzhausen, Jacobus R.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (02) : 1150 - 1157
  • [27] High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage
    Bian, Xingming
    Wang, Liming
    Liu, Yunpeng
    Yang, Yingjian
    Guan, Zhicheng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1971 - 1973
  • [28] The Features of Positive DC Corona Discharge on the Surface of the Conductor with Different Contaminations
    Qi, Xin
    Bian, Xingming
    Lu, Tiebing
    Ma, Wenzuo
    Liu, Yang
    Zhang, Xu
    Cao, Xusu
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 346 - 349
  • [29] Using Current Coefficient to Estimate DC Conductor Corona Onset Voltage
    Zhao, Yuming
    Ma, Minhua
    Chu, Jinwei
    Guan, Zhicheng
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 371 - 374
  • [30] Statistical characteristic in time-domain of direct current corona-generated audible noise from conductor in corona cage
    Li, Xuebao
    Cui, Xiang
    Lu, Tiebing
    Ma, Wenzuo
    Bian, Xingming
    Wang, Donglai
    Hiziroglu, Huseyin
    PHYSICS OF PLASMAS, 2016, 23 (03)