Studies of DC conductor corona in a small corona cage

被引:0
|
作者
Sibilant, GC
Ijumba, NM
Britten, AC
机构
关键词
corona; corona cage; corona current; electric field; high voltage direct current (HVDC); silicon coating; surface gradient;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The complex nature of corona phenomena, combined with the number of factors influencing these effects, make experimental studies indispensable for evaluating the corona performance of transmission lines. Different methods, ranging from tests in laboratory cages to measurements on operational transmission lines, may be used for obtaining the necessary data. This paper gives an introduction to the design of a small corona cage as well as presenting test results obtained from the cage. These tests involved changing the surface conditions of conductors by coating them with silicon, in order to determine their corona performance under the effects of wind. It is concluded that wind in a corona cage does not play a big part in corona loss for a clean conductor. It is recommended that further tests be carried out with a stronger wind source.
引用
收藏
页码:2202 / 2207
页数:6
相关论文
共 50 条
  • [1] Studies of DC conductor corona in a small corona cage
    Sibilant, GC
    Ijumba, NM
    Britten, AC
    2002 IEEE AFRICON, VOLS 1 AND 2: ELECTROTECHNOLOGICAL SERVICES FOR AFRICA, 2002, : 661 - 664
  • [2] Effect of air temperature on DC conductor corona performance in corona cage
    Wang, Wei
    Ding, Yan-Sheng
    Li, Cheng-Rong
    Li, Xiao-Lin
    Luo, Bing
    Yu, Zhuang-Zhuang
    An, Bing
    Wang, Yi-Xu
    Yang, Bo
    Fan, Fei
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 613 - 617
  • [3] Measurement methods for DC conductor corona onset voltage in the corona cage
    Zhao, Yu-Ming
    Ma, Min-Hua
    Chu, Jin-Wei
    Guan, Zhi-Cheng
    Wang, Li-Ming
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (08): : 1567 - 1572
  • [4] The Effect of Wind on Corona Current Generated From DC Conductor in Corona Cage
    Wang, Wei
    Yang, Bo
    Li, Chengrong
    Luo, Bing
    Li, Xiaolin
    Wang, Yixu
    An, Bing
    Fan, Fei
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 152 - +
  • [5] Comparative studies of DC corona losses in a corona cage and a point-plane gap
    Ijumba, N. M.
    Lekganyane, M. J.
    Britten, A. C.
    2007 AFRICON, VOLS 1-3, 2007, : 1286 - +
  • [6] Study of UHV DC corona performance in a mini corona cage
    Wang, Wei
    Li, Chengrong
    Fan, Jianbin
    Gu, Chen
    Jiang, Yitao
    Cui, Guohua
    2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO, 2007, : 459 - +
  • [7] HVDC MONOPOLAR AND BIPOLAR CAGE STUDIES ON THE CORONA PERFORMANCE OF CONDUCTOR BUNDLES
    DALLAIRE, RD
    MARUVADA, PS
    RIVEST, N
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (01): : 84 - 91
  • [8] Corona losses measurement system of bundle conductor using UHV corona cage
    You, Shao-Hua
    Liu, Yun-Peng
    Wan, Qi-Fa
    Lü, Fang-Cheng
    Wu, Xiong
    Chen, Yong
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (01): : 244 - 249
  • [9] Influence of Aged Conductor Surface Conditions on AC Corona Discharge With a Corona Cage
    Bian, Xingming
    Yu, Deming
    Chen, Lan
    MacAlpine, J. M. K.
    Wang, Liming
    Guan, Zhicheng
    Chen, Fangdong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (03) : 809 - 818
  • [10] Ion Current Studies Using A Small Corona Cage
    Wulff, J.
    Vogt, T.
    Jenau, F.
    2015 IEEE 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (IEEE EEEIC 2015), 2015, : 2205 - 2210