Water-contained surfactant-based vortex-assisted microextraction method combined with liquid chromatography for determination of synthetic antioxidants from edible oil

被引:31
作者
Amlashi, Nadiya Ekbatani [1 ]
Hadjmohammadi, Mohammad Reza [1 ]
Nazari, Seyed Saman Seyed Jafar [1 ]
机构
[1] Univ Mazandaran, Dept Chem, Babol Sar, Iran
关键词
Surfactant-based extraction; Vortex-assisted; Synthetic phenolic antioxidants; Edible oil; Experimental design; PHENOLIC ANTIOXIDANTS; BUTYLATED HYDROXYANISOLE; VEGETABLE-OIL; NATURAL ANTIOXIDANT; ORGANIC-COMPOUNDS; FOOD; EXTRACTION; BHT; OPTIMIZATION; TBHQ;
D O I
10.1016/j.chroma.2014.07.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For the first time, a novel water-contained surfactant-based vortex-assisted microextraction method (WSVAME) was developed for the extraction of two synthetic antioxidants (t-butyl hydroquinone (TBHQ) and butylated hydroxyanisole (BHA)) from edible oil samples. The novel microextraction method is based on the injection of an aqueous solution of non-ionic surfactant, Brij-35, into the oil sample in a conical bottom glass tube to form a cloudy solution. Vortex mixing was applied to accelerate the dispersion process. After extraction and phase separation by centrifugation, the lower sediment phase was directly analyzed by HPLC. The effects of the four experimental parameters including volume and concentration of extraction solvent (aqueous solution of Brij-35), percentage of acetic acid added to the oil sample and vortex time on the extraction efficiency were studied with a full factorial design. The central composite design and multiple linear regression method were applied for the construction of the best polynomial model based on experimental recoveries. The proposed method showed good linearity within the range of 0.200-200 mu g mL(-1), the square of correlation coefficient higher than 0.999 and appropriate limit of detection (0.026 and 0.020 mu g mL(-1) for TBHQ and BHA, respectively), while the precision for inner-day was <= 3.0 (n = 5) and it was <= 3.80 (n = 5) for inter-day assay. Under the optimal condition (30 mu L of 0.10 mol L-1 Brij-35 solution as extraction solvent and vortex time 1 min), the method was successfully applied for determination of TBHQ and BHA in different commercial edible oil samples. The recoveries in all cases were above 95%, with relative standard deviations below 5%. This approach is considered as a simple, sensitive and environmentally friendly method because of biodegradability of the extraction phase and no use of organic solvent in the extraction procedure. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 51 条
  • [1] Analytical strategies to evaluate antioxidants in food: a review
    Andre, C.
    Castanheira, I.
    Cruz, J. M.
    Paseiro, P.
    Sanches-Silva, A.
    [J]. TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2010, 21 (05) : 229 - 246
  • [2] AOAC Official Method 983.15 AOAC, 1995, 98315 AOAC
  • [3] Studies on a natural antioxidant for stabilization of edible oil and comparison with synthetic antioxidants
    Bera, D
    Lahiri, D
    Nag, A
    [J]. JOURNAL OF FOOD ENGINEERING, 2006, 74 (04) : 542 - 545
  • [4] Response surface methodology (RSM) as a tool for optimization in analytical chemistry
    Bezerra, Marcos Almeida
    Santelli, Ricardo Erthal
    Oliveira, Eliane Padua
    Villar, Leonardo Silveira
    Escaleira, Luciane Amlia
    [J]. TALANTA, 2008, 76 (05) : 965 - 977
  • [5] TOXICOLOGY AND BIOCHEMISTRY OF BUTYLATED HYDROXYANISOLE AND BUTYLATED HYDROXYTOLUENE
    BRANEN, AL
    [J]. JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1975, 52 (02) : 59 - 63
  • [6] Cadenas E., 1996, Handbook of Antioxidants
  • [7] Determination of Four Synthetic Phenolic Antioxidants in Edible Oils by High-Performance Liquid Chromatography with Cloud Point Extraction Using Tergitol TMN-6
    Chen, Miao
    Hu, Xujia
    Tai, Zhigang
    Qin, Hui
    Tang, Huinan
    Liu, Mousheng
    Yang, Yaling
    [J]. FOOD ANALYTICAL METHODS, 2013, 6 (01) : 28 - 35
  • [8] Cloud-Point Extraction and Reversed-Phase High-Performance Liquid Chromatography for the Determination of Synthetic Phenolic Antioxidants in Edible Oils
    Chen, Miao
    Xia, Qinghai
    Liu, Mousheng
    Yang, Yaling
    [J]. JOURNAL OF FOOD SCIENCE, 2011, 76 (01) : C98 - C103
  • [9] Statistical designs and response surface techniques for the optimization of chromatographic systems
    Costa Ferreira, Sergio Luis
    Bruns, Roy Edward
    Paranhos da Silva, Erik Galvao
    Lopes dos Santos, Walter Nei
    Quintella, Cristina Maria
    David, Jorge Mauricio
    Bittencourt de Andrade, Jailson
    Breitkreitz, Marcia Cristina
    Sales Fontes Jardim, Isabel Cristina
    Barros Neto, Benicio
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1158 (1-2) : 2 - 14
  • [10] Analysis of synthetic phenolic antioxidants in edible oils by micellar electrokinetic capillary chromatography
    Delgado-Zamarreno, M. M.
    Gonzalez-Maza, I.
    Sanchez-Perez, A.
    Carabias Martinez, R.