Characterization of a novel diol column for high-performance liquid chromatography

被引:65
|
作者
Tanaka, H [1 ]
Zhou, XJ [1 ]
Masayoshi, O [1 ]
机构
[1] GL Sci Inc, Fukushima 9608201, Japan
关键词
stationary phases; LC; hydrophilic interaction chromatography; amino acids; glucose; sugars;
D O I
10.1016/S0021-9673(02)01949-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For the investigation of a diol phase (Inertsil Diol column) in hydrophilic interaction chromatography, urea, sucrose and glycine were used as test compounds. The chromatographic conditions were investigated for optimal column efficiency. The column temperature used in common reversed-phase liquid chromatography could also be used for the separation and the flow-rate should be adjusted to 0.3-0.5 ml/min to optimize column efficiency. It is suggested that the velocity of the hydrophilic interaction is slower than the hydrophobic interaction in RPLC. The addition of trifluoroacetic acid is effective for the retention of glycine, but ineffective for urea and sucrose. The diol phase exhibited sufficient chemical stability even if exposed to water in high percentage, and could be applied with isocratic elution for the separation/analysis of amino acids and glucose. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 50 条
  • [1] Isocratic separation of ginsenosides by high-performance liquid chromatography on a diol column at subambient temperatures
    Lou, DW
    Saito, Y
    Zarzycki, PK
    Ogawa, M
    Jinno, K
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (01) : 96 - 104
  • [2] Isocratic separation of ginsenosides by high-performance liquid chromatography on a diol column at subambient temperatures
    Da-Wei Lou
    Yoshihiro Saito
    Paweł K. Zarzycki
    Mitsuhiro Ogawa
    Kiyokatsu Jinno
    Analytical and Bioanalytical Chemistry, 2006, 385 : 96 - 104
  • [3] INJECTOR FOR HIGH-PERFORMANCE LIQUID COLUMN CHROMATOGRAPHY
    STRANEL, O
    MLADEK, M
    CHEMICKE LISTY, 1984, 78 (03): : 312 - 314
  • [4] CHARACTERIZATION AND PURIFICATION OF IRON PORPHYRINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COLUMN CHROMATOGRAPHY
    DIXON, DW
    AMIS, L
    KIM, MS
    CALLAHAN, J
    JOURNAL OF CHROMATOGRAPHY, 1989, 462 : 411 - 418
  • [5] HIGH-PERFORMANCE LIQUID COLUMN CHROMATOGRAPHY OF URINARY POLYAMINES
    MACEK, K
    DEYL, Z
    JIRANEK, J
    SMRZ, M
    SBORNIK LEKARSKY, 1978, 80 (02): : 44 - 48
  • [6] Column radial homogeneity in high-performance liquid chromatography
    Farkas, T
    Sepaniak, MJ
    Guiochon, G
    JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (02) : 169 - 181
  • [7] PELLICULAR COLUMN MATERIALS FOR HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    HORVATH, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1972, : 14 - &
  • [8] HIGH-PERFORMANCE LIQUID COLUMN CHROMATOGRAPHY OF FENOPROFEN IN SERUM
    MICELI, JN
    RYAN, DM
    DONE, AK
    JOURNAL OF CHROMATOGRAPHY, 1980, 183 (02): : 250 - 254
  • [9] CHARACTERIZATION OF CARRAGEENANS BY HIGH-PERFORMANCE SIZE-EXCLUSION CHROMATOGRAPHY USING A LICHROSPHER 1000 DIOL COLUMN
    SWORN, G
    MARRS, WM
    HART, RJ
    JOURNAL OF CHROMATOGRAPHY, 1987, 403 : 307 - 311
  • [10] RpeakChrom: Novel R package for the automated characterization and optimization of column efficiency in high-performance liquid chromatography analysis
    David Peris-Diaz, Manuel
    Isabel Alcoriza-Balaguer, Maria
    Carlos Garcia-Canaveras, Juan
    Santonja, Francisco
    Sentandreu, Enrique
    Lahoz, Agustin
    ELECTROPHORESIS, 2017, 38 (22-23) : 2985 - 2995