Are Custom Triflange Acetabular Components Effective for Reconstruction of Catastrophic Bone Loss?

被引:90
作者
Berasi, Carl C. [1 ]
Berend, Keith R. [2 ,3 ,4 ]
Adams, Joanne B. [2 ]
Ruh, Erin L. [2 ]
Lombardi, Adolph V., Jr. [2 ,3 ,4 ]
机构
[1] Riverside Methodist Hosp, Columbus, OH 43214 USA
[2] Joint Implant Surg Inc, New Albany, OH 43054 USA
[3] Ohio State Univ, Wexner Med Ctr, Columbus, OH 43210 USA
[4] Mt Carmel Hlth Syst, New Albany, OH USA
关键词
TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; FOLLOW-UP; REVISION ARTHROPLASTY; DEFECTS; CAGE; DEFICIENCY; ALLOGRAFTS; CEMENT; STOCK;
D O I
10.1007/s11999-014-3969-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although the introduction of ultraporous metals in the forms of acetabular components and augments has increased the orthopaedic surgeon's ability to reconstruct severely compromised acetabuli, there remain some that cannot be managed readily using cups, augments, or cages. In such situations, allograft-prosthetic composites or custom acetabular components may be called for. However, few studies have reported on the results of these components. The purposes of this study were to determine the (1) frequency of repeat revision, (2) complications and radiographic findings, and (3) Harris hip scores in patients who underwent complex acetabular revision surgery with custom acetabular components. Between August 2003 and February 2012, 26 patients (28 hips) have undergone acetabular reconstruction with custom triflange components. During this time, the general indications for using these implants included (1) failed prior salvage reconstruction with cage or porous metal construct augments, (2) large contained defects with possible discontinuity, (3) known pelvic discontinuity, and (4) complex multiply surgically treated hips with insufficient bone stock to reconstruct using other means. This approach was used in a cohort of patients with Paprosky Type 3B acetabular defects, which represented 3% (30 of 955) of the acetabular revisions we performed during the study period. Minimum followup was 2 years (mean, 57 months; range, 28-108 months). Seven patients (eight hips) died during the study period, and three (11%) of these patients (four hips; 14%) were lost to followup before 2 years, leaving 23 patients (24 hips) with minimum 2-year followup. Sixteen patients were women. The mean age of the patients was 67 years (range, 47-85 years) and mean BMI was 28 kg/m(2) (range, 23-39 kg/m(2)). Revisions and complications were identified by chart review; hip scores were registered in our institution's longitudinal database. Pre- and postoperative radiographs were analyzed by the patient's surgeon to determine whether migration, fracture of fixation screws, or continued bone loss had occurred. There have been four subsequent surgical interventions: two failures secondary to sepsis, and one stem revision and one open reduction internal fixation for periprosthetic femoral fracture. There were two minor complications managed nonoperatively, but all of the components were noted to be well-fixed with no obvious migration or loosening observed on the most recent radiographs. Harris hip scores improved from a mean of 42 (SD, +/- A 16) before surgery to 65 (SD, +/- A 18) at latest followup (p < 0.001). Custom acetabular triflange components represent yet another tool in the reconstructive surgeon's armamentarium. These devices can be helpful in situations of catastrophic bone loss. Level IV, therapeutic study.
引用
收藏
页码:528 / 535
页数:8
相关论文
共 50 条
  • [31] Reconstruction of failed acetabular component in the presence of severe acetabular bone loss: a systematic review
    Volpin A.
    Konan S.
    Biz C.
    Tansey R.J.
    Haddad F.S.
    MUSCULOSKELETAL SURGERY, 2019, 103 (1) : 1 - 13
  • [32] A modified custom-made triflanged acetabular reconstruction ring (MCTARR) for revision hip arthroplasty with severe acetabular defects
    Colen, Sascha
    Harake, Ramzi
    De Haan, Julien
    Muleir, Michiel
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (01): : 71 - 75
  • [33] Use of porous trabecular metal augments with impaction bone grafting in management of acetabular bone loss Early to medium-term results
    Borland, W. Steven
    Bhattacharya, Raj
    Holland, James P.
    Brewster, Nigel T.
    ACTA ORTHOPAEDICA, 2012, 83 (04) : 347 - 352
  • [34] Custom 3D-Printed Implants for Acetabular Reconstruction
    Di Laura, Anna
    Henckel, Johann
    Hart, Alister
    JBJS OPEN ACCESS, 2023, 8 (02)
  • [35] Trabecular metal augments in severe malignancy-associated acetabular bone loss
    Melnic, Christopher M.
    Salimy, Mehdi S.
    Hosseinzadeh, Shayan
    Moverman, Michael A.
    Bedair, Hany S.
    Lozano-Calderon, Santiago A.
    Raskin, Kevin A.
    HIP INTERNATIONAL, 2023, 33 (04) : 678 - 684
  • [36] Risk factors for implant failure of custom-made acetabular implants in patients with Paprosky III acetabular bone loss and combined pelvic discontinuity
    Froeschen, Frank S.
    Randau, Thomas M.
    Gravius, Nadine
    Wirtz, Dieter C.
    Gravius, Sascha
    Walter, Sebastian G.
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (03) : 703 - 711
  • [37] Outcome of repeated multi-stage arthroplasty with custom-made acetabular implants in patients with severe acetabular bone loss: a case series
    Froeschen, Frank S.
    Randau, Thomas M.
    Hischebeth, Gunnar T. R.
    Gravius, Nadine
    Wirtz, Dieter C.
    Gravius, Sascha
    Walter, Sebastian G.
    HIP INTERNATIONAL, 2020, 30 (1_SUPPL) : 64 - 71
  • [38] Corrosion of Modular Dual-Mobility Acetabular Components Leading to Acetabular Bone Loss and Protrusio
    Yang, JaeWon
    Dasari, Suhas P.
    Chansky, Howard A.
    Hernandez, Nicholas M.
    ARTHROPLASTY TODAY, 2024, 30
  • [39] The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up
    Kieser, David C.
    Ailabouni, Ramez
    Kieser, Sandra C. J.
    Wyatt, Michael C.
    Armour, Paul C.
    Coates, Mark H.
    Hooper, Gary J.
    HIP INTERNATIONAL, 2018, 28 (06) : 668 - 674
  • [40] Custom 3D-Printed Triflange Implants for Treatment of Severe Acetabular Defects, with and without Pelvic Discontinuity: Early Results of Our First 19 Consecutive Cases
    Goriainov, Vitali
    King, Leonard J.
    Oreffo, Richard O. C.
    Dunlop, Douglas G.
    JBJS OPEN ACCESS, 2021, 6 (04)