Are Custom Triflange Acetabular Components Effective for Reconstruction of Catastrophic Bone Loss?

被引:90
|
作者
Berasi, Carl C. [1 ]
Berend, Keith R. [2 ,3 ,4 ]
Adams, Joanne B. [2 ]
Ruh, Erin L. [2 ]
Lombardi, Adolph V., Jr. [2 ,3 ,4 ]
机构
[1] Riverside Methodist Hosp, Columbus, OH 43214 USA
[2] Joint Implant Surg Inc, New Albany, OH 43054 USA
[3] Ohio State Univ, Wexner Med Ctr, Columbus, OH 43210 USA
[4] Mt Carmel Hlth Syst, New Albany, OH USA
关键词
TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; FOLLOW-UP; REVISION ARTHROPLASTY; DEFECTS; CAGE; DEFICIENCY; ALLOGRAFTS; CEMENT; STOCK;
D O I
10.1007/s11999-014-3969-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although the introduction of ultraporous metals in the forms of acetabular components and augments has increased the orthopaedic surgeon's ability to reconstruct severely compromised acetabuli, there remain some that cannot be managed readily using cups, augments, or cages. In such situations, allograft-prosthetic composites or custom acetabular components may be called for. However, few studies have reported on the results of these components. The purposes of this study were to determine the (1) frequency of repeat revision, (2) complications and radiographic findings, and (3) Harris hip scores in patients who underwent complex acetabular revision surgery with custom acetabular components. Between August 2003 and February 2012, 26 patients (28 hips) have undergone acetabular reconstruction with custom triflange components. During this time, the general indications for using these implants included (1) failed prior salvage reconstruction with cage or porous metal construct augments, (2) large contained defects with possible discontinuity, (3) known pelvic discontinuity, and (4) complex multiply surgically treated hips with insufficient bone stock to reconstruct using other means. This approach was used in a cohort of patients with Paprosky Type 3B acetabular defects, which represented 3% (30 of 955) of the acetabular revisions we performed during the study period. Minimum followup was 2 years (mean, 57 months; range, 28-108 months). Seven patients (eight hips) died during the study period, and three (11%) of these patients (four hips; 14%) were lost to followup before 2 years, leaving 23 patients (24 hips) with minimum 2-year followup. Sixteen patients were women. The mean age of the patients was 67 years (range, 47-85 years) and mean BMI was 28 kg/m(2) (range, 23-39 kg/m(2)). Revisions and complications were identified by chart review; hip scores were registered in our institution's longitudinal database. Pre- and postoperative radiographs were analyzed by the patient's surgeon to determine whether migration, fracture of fixation screws, or continued bone loss had occurred. There have been four subsequent surgical interventions: two failures secondary to sepsis, and one stem revision and one open reduction internal fixation for periprosthetic femoral fracture. There were two minor complications managed nonoperatively, but all of the components were noted to be well-fixed with no obvious migration or loosening observed on the most recent radiographs. Harris hip scores improved from a mean of 42 (SD, +/- A 16) before surgery to 65 (SD, +/- A 18) at latest followup (p < 0.001). Custom acetabular triflange components represent yet another tool in the reconstructive surgeon's armamentarium. These devices can be helpful in situations of catastrophic bone loss. Level IV, therapeutic study.
引用
收藏
页码:528 / 535
页数:8
相关论文
共 50 条
  • [21] In Which Patients Should a Custom-Made Acetabular Implant (Triflange Cup) Be Used?
    Dzhavadov, Alisagib A.
    Huang, Wei
    Li, Huiwu
    Noor, Syed Shahid
    Parvizi, Javad
    Shahi, Alisina
    Sheth, Neil P.
    Tetsworth, Kevin
    Tikhilov, Rashid M.
    Villafuerte, Jorge A.
    Zagra, Luigi
    JOURNAL OF ARTHROPLASTY, 2025, 40 (02) : S188 - S189
  • [22] Bone Loss Around the Acetabular Component
    Howell, Jonathan
    Bolland, Ben
    EUROPEAN INSTRUCTIONAL LECTURES, VOL 11, 2011, 11 : 155 - 166
  • [23] Use of custom-made acetabular components (CMAC) as part of a two-stage procedure in patients with severe periacetabular bone loss
    Froeschen, Frank Sebastian
    Randau, Thomas Martin
    Walter, Sebastian Gottfried
    Dally, Franz
    Wirtz, Dieter Christian
    Gravius, Sascha
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2022, 34 (05): : 361 - 371
  • [24] Custom-made triflanged acetabular components in the treatment of major acetabular defects. Short-term results and clinical experience
    Myncke, Irisa
    van Schaik, David
    Scheerlinck, Thierry
    ACTA ORTHOPAEDICA BELGICA, 2017, 83 (03): : 341 - 350
  • [25] Impaction bone grafting for acetabular reconstruction: mean 5.5-year results in Japanese patients
    Iwase, Toshiki
    Masui, Tetsuo
    Torii, Yukio
    Kouyama, Atsushi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (04) : 433 - 439
  • [26] Cemented acetabular components combined with trabecular metal augments provide excellent long-term survivorship for severe acetabular bone loss
    Garala, Kanai
    Remtulla, Mohammed Abbas
    Verma, Raghav
    Lawrence, Trevor
    HIP INTERNATIONAL, 2023, 33 (05) : 833 - 838
  • [27] Management of Complex Acetabular Revision With Bone Loss
    Rocha, Jorge L.
    O'Malley, Michael J.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2019, 29 (03)
  • [28] Acetabular reconstruction using morcellised bone with ring support - Medium term results at three to nine years
    Krishnan, Kamalakannan Murali
    Longstaff, Lee
    Partington, Paul
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (01): : 61 - 67
  • [29] Acetabular distraction AN ALTERNATIVE FOR SEVERE ACETABULAR BONE LOSS AND CHRONIC PELVIC DISCONTINUITY
    Sheth, N. P.
    Melnic, C. M.
    Paprosky, W. G.
    BONE & JOINT JOURNAL, 2014, 96B : 36 - 42
  • [30] Hip Arthroplasty With the Use of a Reconstruction Cage and Porous Metal Augment to Treat Massive Acetabular Bone Loss: A Midterm Follow-Up
    Garceau, Simon P.
    Warschawski, Yaniv
    Joly, Denis
    Safir, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07) : S636 - S641