Evaluating the Relationship of Intraocular Pressure and Anterior Chamber Volume With Use of Prostaglandin Analogues

被引:7
作者
Scott, Jessica A. [1 ,3 ]
Roberts, Cynthia J. [1 ,2 ]
Mahmoud, Ashraf M. [1 ,2 ]
Jain, Shelly Gupta [1 ]
机构
[1] Ohio State Univ, Dept Ophthalmol & Vis Sci, Havener Eye Inst, Wexner Med Ctr, 915 Olentangy River Rd, Columbus, OH 43212 USA
[2] Ohio State Univ, Dept Biomed Engn, Wexner Med Ctr, Havener Eye Inst, Columbus, OH 43210 USA
[3] Columbia Univ, New York, NY USA
关键词
prostaglandin; anterior chamber volume; biomechanics; ocular rigidity; glaucoma; intraocular pressure; DYNAMIC CONTOUR TONOMETRY; CORNEAL BIOMECHANICAL PROPERTIES; GOLDMANN APPLANATION TONOMETRY; AIR-PUFF; DEFORMATION; EYES; LATANOPROST; PARAMETERS; SCLERA; IMPACT;
D O I
10.1097/IJG.0000000000001736
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: In this prospective study, naive prostaglandin use in primary open-angle glaucoma was associated with scleral biomechanical alteration and intraocular pressure (IOP) measuring errors. Purpose: The purpose of this study is to determine the effects of naive use of prostaglandin analogues (PGA) on IOP and anterior chamber volume (ACV), as well as investigate how PGAs might affect corneal and scleral stiffness and their impact on ocular rigidity. Materials and Methods: This study was a prospective study of 21 recently diagnosed open-angle glaucoma patients (33 eyes) initiating medical therapy with a topical prostaglandin eye drop. Corneal morphologic and biomechanical parameters as well as IOP were measured at 3 visits over a 4-month period with the following equipment: Pentacam, Corvis ST, Ocular Response Analyzer, Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry. Results: The study demonstrated a significant decrease in mean IOP with initiation of PGA in all 4 tonometers (P<0.0001). The greatest change in IOP occurred in the first 4 weeks of treatment (P<0.0001). The mean ACV showed a significant decrease at visit 2 (P<0.02) and visit 3 (P<0.04) compared with baseline visit 1. However, there was a paradoxical increase in ACV in 37% of eyes at visit 2, despite a significant mean reduction in IOP by GAT and dynamic contour tonometry. The IOP/ACV ratio at visit 1 significantly predicted the reduction in respective measures of IOP, as well as scleral stiffness measured by stiffness parameter-highest concavity. Conclusion: In clinical practice, GAT may not be the most appropriate tonometer for measuring IOP in PGA treated eyes due the measurement errors from ocular biomechanical alteration. The IOP/ACV ratio could potentially serve as a new diagnostic parameter to determine the likelihood of PGA treatment success.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 29 条
  • [1] Efficacy and Tolerability of Prostaglandin Analogs A Meta-analysis of Randomized Controlled Clinical Trials
    Aptel, Florent
    Cucherat, Michel
    Denis, Philippe
    [J]. JOURNAL OF GLAUCOMA, 2008, 17 (08) : 667 - 673
  • [2] The elasticity of veins
    Clark, JH
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1933, 105 (02): : 418 - 427
  • [3] Corneal Biomechanical Properties Affect Goldmann Applanation Tonometry in Primary Open-angle Glaucoma
    Costin, Bryan R.
    Fleming, Gloria P.
    Weber, Paul A.
    Mahmoud, Ashraf M.
    Roberts, Cynthia J.
    [J]. JOURNAL OF GLAUCOMA, 2014, 23 (02) : 69 - 74
  • [4] Ocular Rigidity, Ocular Pulse Amplitude, and Pulsatile Ocular Blood Flow: The Effect of Intraocular Pressure
    Dastiridou, Anna I.
    Ginis, Harilaos S.
    De Brouwere, Dirk
    Tsilimbaris, Miltiadis K.
    Pallikaris, Ioannis G.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (12) : 5718 - 5722
  • [5] Applanation Tonometry Versus Dynamic Contour Tonometry in Eyes Treated With Latanoprost
    Detorakis, Efstathios T.
    Arvanitaki, Vasiliki
    Pallikaris, Ioannis G.
    Kymionis, George
    Tsilimbaris, Miltiadis K.
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (03) : 194 - 198
  • [6] Friedenwald JS., 1937, AM J OPHTHALMOL, V20, P985, DOI [10.1016/S0002-9394(37)90425-2, DOI 10.1016/S0002-9394(37)90425-2]
  • [7] Short-term effects of latanoprost on anterior chamber depth in patients with glaucoma or ocular hypertension
    Gutierrez-Ortiz, Consuelo
    Teus, Miguel A.
    Bolivar, Gema
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) : 4856 - 4859
  • [8] Glaucoma
    Hong, Chris J.
    Trope, Graham E.
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2015, 187 (12) : E398 - E399
  • [9] Dynamic contour tonometry - Presentation of a new tonometer
    Kanngiesser, HE
    Kniestedt, C
    Robert, YCA
    [J]. JOURNAL OF GLAUCOMA, 2005, 14 (05) : 344 - 350
  • [10] Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states
    Kniestedt, C
    Nee, M
    Stamper, RL
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (04) : 359 - 366