Improved detection of multiple sclerosis lesions with T2-prepared double inversion recovery at 3T

被引:6
|
作者
Costagli, Mauro [1 ,2 ]
Lapucci, Caterina [1 ,3 ]
Zaca, Domenico [4 ]
Bruschi, Nicolo [1 ]
Schiavi, Simona [1 ]
Castellan, Lucio [3 ]
Stemmer, Alto [5 ]
Roccatagliata, Luca [3 ,6 ]
Inglese, Matilde [1 ,3 ]
机构
[1] Univ Genoa, Dept Neurosci Rehabil Ophthalmol Genet Maternal &, Genoa, Italy
[2] IRCCS Stella Maris, Lab Med Phys & Magnet Resonance, Pisa, Italy
[3] IRCCS Osped Policlin San Martino, Genoa, Italy
[4] Siemens Healthcare, Milan, Italy
[5] Siemens Healthcare, Erlangen, Germany
[6] Univ Genoa, Dept Hlth Sci DISSAL, Genoa, Italy
关键词
cervical cord; gray matter; magnetic resonance imaging; multiple sclerosis; optic nerve; MAGNETIZATION-PREPARED; 3D-FLAIR; PULSE SEQUENCE; WHITE-MATTER; SPINAL-CORD; MR-IMAGES; FIELD; DIAGNOSIS; FLAIR;
D O I
10.1111/jon.13021
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose Double inversion recovery (DIR) imaging is used in multiple sclerosis (MS) clinical protocols to improve the detection of cortical and juxtacortical gray matter lesions by nulling confounding signals originating from the cerebrospinal fluid and white matter. Achieving a high isotropic spatial resolution, to depict the neocortex and its typically small lesions, is challenged by the reduced signal-to-noise ratio (SNR) determined by multiple tissue signal nulling. Here, we evaluate both conventional and optimized DIR implementations to improve tissue contrast (TC), SNR, and MS lesion conspicuity. Methods DIR images were obtained from MS patients and healthy controls using both conventional and prototype implementations featuring a T2-preparation module (T2P), to improve SNR and TC, as well as an image reconstruction routine with iterative denoising (ID). We obtained quantitative measures of SNR and TC, and evaluated the visibility of MS cortical, cervical cord, and optic nerve lesions in the different DIR images. Results DIR implementations adopting T2P and ID enabled improving the SNR and TC of conventional DIR. In MS patients, 34% of cortical, optic nerve, and cervical cord lesions were visible only in DIR images acquired with T2P, and not in conventional DIR images. In the studied cases, image reconstruction with ID did not improve lesion conspicuity. Conclusions DIR with T2P should be preferred to conventional DIR imaging in protocols studying MS patients, as it improves SNR and TC and determines an improvement in cortical, optic nerve, and cervical cord lesion conspicuity.
引用
收藏
页码:902 / 909
页数:8
相关论文
共 50 条
  • [21] Improved detection of focal cortical lesions using 7 T magnetisation transfer imaging in patients with multiple sclerosis
    Abdel-Fahim, R.
    Mistry, N.
    Mougin, O.
    Blazejewska, A.
    Pitiot, A.
    Retkute, R.
    Gowland, P.
    Evangelou, N.
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2014, 3 (02) : 258 - 265
  • [22] Optimisation of T2*-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T
    Dixon, Jennifer Elizabeth
    Simpson, Ashley
    Mistry, Niraj
    Evangelou, Nikos
    Morris, Peter Gordon
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : 719 - 727
  • [23] Phase sensitive reconstruction of T1-weighted inversion recovery in the evaluation of the cervical cord lesions in Multiple Sclerosis; is it similarly eligible in 1.5 T magnet fields?
    Shayganfar, A.
    Sarrami, A. H.
    Fathi, S.
    Shaygannejad, V
    Shamsian, S.
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2018, 23 : 17 - 22
  • [24] Improving Detection of Multiple Sclerosis Lesions in the Posterior Fossa Using an Optimized 3D-FLAIR Sequence at 3T
    Lecler, A.
    El Sanharawi, I.
    El Methni, J.
    Gout, O.
    Koskas, P.
    Savatovsky, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (07) : 1170 - 1176
  • [25] Fully automated detection of paramagnetic rims in multiple sclerosis lesions on 3T susceptibility-based MR imaging
    Lou, Carolyn
    Sati, Pascal
    Absinta, Martina
    Clark, Kelly
    Dworkin, Jordan D.
    Valcarcel, Alessandra M.
    Schindler, Matthew K.
    Reich, Daniel S.
    Sweeney, Elizabeth M.
    Shinohara, Russell T.
    NEUROIMAGE-CLINICAL, 2021, 32
  • [26] Detectability of multiple sclerosis lesions with 3T MRI: A comparison of proton density-weighted and FLAIR sequences
    Schmidt, Christoph
    Hattingen, Elke
    Faehndrich, Julia
    Jurcoane, Alina
    Porto, Luciana
    JOURNAL OF NEURORADIOLOGY, 2012, 39 (01) : 51 - 56
  • [27] Comparative between Double Inversion Recovery and Fluid-Attenuated Inversion Recovery Sequences for Detection of Brain Multiple Sclerosis
    Elhussein, Nagwan
    Alazmi, Norah
    Fadulemulla, Ibtisam Abdallah
    Hamd, Zuhal Yassin
    Ahmed, Amna Mohamed
    Seifeldin, Sara A.
    Alshammari, Qurain Turki
    CLINICAL CANCER INVESTIGATION JOURNAL, 2022, 11 (06): : 41 - 44
  • [28] Paramagnetic Rim Lesions are Specific to Multiple Sclerosis: An International Multicenter 3T MRI Study
    Maggi, Pietro
    Sati, Pascal
    Nair, Govind
    Cortese, Irene C. M.
    Jacobson, Steven
    Smith, Bryan R.
    Nath, Avindra
    Ohayon, Joan
    van Pesch, Vincent
    Perrotta, Gaetano
    Pot, Caroline
    Theaudin, Marie
    Martinelli, Vittorio
    Scotti, Roberta
    Wu, Tianxia
    Du Pasquier, Renaud
    Calabresi, Peter A.
    Filippi, Massimo
    Reich, Daniel S.
    Absinta, Martina
    ANNALS OF NEUROLOGY, 2020, 88 (05) : 1034 - 1042
  • [29] Intracortical lesions by 3T magnetic resonance imaging and correlation with cognitive impairment in multiple sclerosis
    Nelson, Flavia
    Datta, Sushmita
    Garcia, Nereyda
    Rozario, Nigel L.
    Perez, Francisco
    Cutter, Gary
    Narayana, Ponnada A.
    Wolinsky, Jerry S.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 (09) : 1122 - 1129
  • [30] Detection of Spinal Cord Multiple Sclerosis Lesions Using a 3D-PSIR Sequence at 1.5 T
    Peters, Soenke
    Neves, Fernando Bueno
    Huhndorf, Monika
    Gaertner, Friederike
    Stuerner, Klarissa
    Jansen, Olav
    Ravesh, Mona Salehi
    CLINICAL NEURORADIOLOGY, 2024, 34 (02) : 403 - 410