Intelligent fault analysis of transmission line using phasor measurement unit incorporating auto-reclosure protection scheme

被引:0
|
作者
Swain, Kunjabihari [1 ]
Cherukuri, Murthy [1 ]
机构
[1] Natl Inst Sci & Technol, Elect & Elect Engn, Berhampur 761008, Odisha, India
来源
SN APPLIED SCIENCES | 2021年 / 3卷 / 05期
关键词
Phasor measurement unit; Power system protection; Fault perception; Fault comprehension; Phaselet; Extreme learning machine; CLASSIFICATION; LOCATION; METHODOLOGY; ALGORITHM; MACHINE;
D O I
10.1007/s42452-021-04510-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The power system stability and reliability are stimulated by the faults on the transmission line. Many researchers have explored the performance of the transmission system under various kinds of faults. Specifically, the arrival of expeditious and effective data acquisition systems with high rate of sampling has set down the foundation for successful real-time monitoring. Using the LabVIEW and the data acquisition system's of National Instruments (NI), virtual systems have been developed for obtaining optimal paradigmatic data with appropriate characterization and quality transmission. The primary objective of the work is to perceive and comprehend the transmission line faults with the aid of synchronized phasor measurements obtained from the phasor measurement unit (PMU) as well as protecting the system using auto-reclosing signal. The developed algorithms include phaselet coefficients for perception as well as comprehension. In order to increase the accuracy, particle swarm optimized extreme learning machine technique has also been used for comprehension. A protection scheme is employed using auto-reclosing to minimize the power loss and quick reconnection the power line in case of temporary fault. Developed algorithms have been validated on a practical laboratory transmission line using NI PMU. As the LabVIEW platform has been used for simulations, it is composed of visual displays such that the system operator can efficiently perform the planning and control decisions.
引用
收藏
页数:15
相关论文
共 35 条
  • [21] Phasor Measurement Unit-Driven Estimation of Transmission Line Parameters Using Variable Noise Model
    de Albuquerque, Felipe Proenca
    Nascimento, Rafael
    Prete Jr, Carlos A.
    da Costa, Eduardo Coelho Marques
    ENERGIES, 2024, 17 (14)
  • [22] Improving protection of compensated transmission line using IoT enabled adaptive auto reclosing scheme
    Konda, Deepthi
    Patel, Ujjaval
    Rathi, Ronak
    Shah, Jaynil
    Chothani, Nilesh
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2024, 25 (05) : 675 - 691
  • [23] A Novel Back Up Wide Area Protection Technique for Power Transmission Grids Using Phasor Measurement Unit
    Eissa, M. M.
    Masoud, M. Elshahat
    Elanwar, M. Magdy Mohamed
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) : 270 - 278
  • [24] Wavelet operated single index based fault detection scheme for transmission line protection with swarm intelligent support
    Ch. Durga Prasad
    Monalisa Biswal
    Paresh Kumar Nayak
    Energy Systems, 2021, 12 : 373 - 392
  • [25] Wavelet operated single index based fault detection scheme for transmission line protection with swarm intelligent support
    Prasad, Ch Durga
    Biswal, Monalisa
    Nayak, Paresh Kumar
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2021, 12 (02): : 373 - 392
  • [26] Adaptive digital distance relay for SSSC-based double-circuit transmission line using phasor measurement unit
    Dhenuvakonda, Koteswara Raju
    Singh, Arvind
    Thakre, Mohan P.
    Karasani, Raghavendra Reddy
    Naidoo, Raj
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (04):
  • [27] Fault Events Recognition to Design a Current Based Transmission Line Protection Scheme Using Signal Processing Techniques
    Chouhan, Dharmendra
    Bhaskar, M. K.
    Mahela, Om Prakash
    2022 SECOND INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL, COMPUTING, COMMUNICATION AND SUSTAINABLE TECHNOLOGIES (ICAECT), 2022,
  • [28] Real-World case studies on transmission line fault location feasibility by using M-Class phasor measurement units
    Lopes, Felipe V.
    Mouco, Arthur
    Fernandes, Rafael O.
    Neto, Felipe C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 196
  • [29] An Adaptive Secure-Dependable Wide-Area Backup Protection Scheme for Transmission Lines Using Multi-Phasor Measurement Units
    Mallikarjuna, B.
    Meyur, Rounak
    Pal, Diptak
    Reddy, M. Jaya Bharata
    Mohanta, D. K.
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,
  • [30] A modular neuro-wavelet based non-unit protection scheme for zone identification and fault location in six-phase transmission line
    Koley, Ebha
    Verma, Khushaboo
    Ghosh, Subhojit
    NEURAL COMPUTING & APPLICATIONS, 2017, 28 (06): : 1369 - 1385