Intelligent fault analysis of transmission line using phasor measurement unit incorporating auto-reclosure protection scheme

被引:0
|
作者
Swain, Kunjabihari [1 ]
Cherukuri, Murthy [1 ]
机构
[1] Natl Inst Sci & Technol, Elect & Elect Engn, Berhampur 761008, Odisha, India
来源
SN APPLIED SCIENCES | 2021年 / 3卷 / 05期
关键词
Phasor measurement unit; Power system protection; Fault perception; Fault comprehension; Phaselet; Extreme learning machine; CLASSIFICATION; LOCATION; METHODOLOGY; ALGORITHM; MACHINE;
D O I
10.1007/s42452-021-04510-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The power system stability and reliability are stimulated by the faults on the transmission line. Many researchers have explored the performance of the transmission system under various kinds of faults. Specifically, the arrival of expeditious and effective data acquisition systems with high rate of sampling has set down the foundation for successful real-time monitoring. Using the LabVIEW and the data acquisition system's of National Instruments (NI), virtual systems have been developed for obtaining optimal paradigmatic data with appropriate characterization and quality transmission. The primary objective of the work is to perceive and comprehend the transmission line faults with the aid of synchronized phasor measurements obtained from the phasor measurement unit (PMU) as well as protecting the system using auto-reclosing signal. The developed algorithms include phaselet coefficients for perception as well as comprehension. In order to increase the accuracy, particle swarm optimized extreme learning machine technique has also been used for comprehension. A protection scheme is employed using auto-reclosing to minimize the power loss and quick reconnection the power line in case of temporary fault. Developed algorithms have been validated on a practical laboratory transmission line using NI PMU. As the LabVIEW platform has been used for simulations, it is composed of visual displays such that the system operator can efficiently perform the planning and control decisions.
引用
收藏
页数:15
相关论文
共 35 条
  • [1] Intelligent fault analysis of transmission line using phasor measurement unit incorporating auto-reclosure protection scheme
    Kunjabihari Swain
    Murthy Cherukuri
    SN Applied Sciences, 2021, 3
  • [2] Phasor measurement unit based transmission line protection scheme design
    Zadeh, Hassan Khorashadi
    Li, Zuyi
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (02) : 421 - 429
  • [3] Design of a novel phasor measurement unit-based transmission line auto reclosing scheme
    Khorashadi-Zadeh, H.
    Li, Z.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (08) : 806 - 813
  • [4] Fault Location Scheme on a Three Phase Transmission Line using Synchronized Phasor Measurement
    Anees, Ahmed Sharique
    Jamil, Majid
    Rizwan, M.
    2012 IEEE 5TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE 2012), 2012,
  • [5] Analysis of Fault Location Algorithm for Transmission Line Protection Based on Synchronized Phasor Measurement
    Muddebihalkar, Sunita V.
    Jadhav, Ganesh N.
    2015 INTERNATIONAL CONFERENCE ON ENERGY SYSTEMS AND APPLICATIONS, 2015, : 118 - 123
  • [6] Analysis of Transmission Line Current Differential Protection Scheme Based on Synchronized Phasor Measurement
    Muddebihalkar, Sunita V.
    Jadhav, Ganesh N.
    2015 CONFERENCE ON POWER, CONTROL, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES FOR SUSTAINABLE GROWTH (PCCCTSG), 2015, : 21 - 25
  • [7] Locating Fault on Transmission Line with Static Var Compensator Based on Phasor Measurement Unit
    Ngo Minh Khoa
    Doan Duc Tung
    ENERGIES, 2018, 11 (09)
  • [8] Iterative Fault Location Scheme for a Transmission Line Using Synchronized Phasor Measurements
    Brahma, Sukumar M.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2007, 8 (06):
  • [9] Fault Identification of double Circuit Transmission Lines using Phasor Measurement Unit
    Chauhan, Surinder
    Dahiya, Ratna
    2018 IEEE 8TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2018,
  • [10] PHASOR MEASUREMENT UNIT BASED WIDE AREA BACKUP PROTECTION SCHEME FOR POWER TRANSMISSION LINES
    Rathinam, A.
    Vanila, S.
    Harika, Ch.
    FIRST INTERNATIONAL CONFERENCE ON POWER ENGINEERING COMPUTING AND CONTROL (PECCON-2017 ), 2017, 117 : 1172 - 1181