A simple and inexpensive test-rig for evaluating the performance of motion sensors used in movement disorders research

被引:8
作者
Perera, Thushara [1 ]
Yohanandan, Shivanthan A. C. [1 ,2 ]
McDermott, Hugh J. [1 ,3 ]
机构
[1] Bion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
[2] Univ Melbourne, Dept Elect & Elect Engn, Parkville, Vic 3010, Australia
[3] Univ Melbourne, Med Bion Dept, Parkville, Vic 3010, Australia
关键词
Accelerometer; Electromagnetic; Movement disorders; Motion tracking; Tremor; PARKINSONS-DISEASE; TREMOR;
D O I
10.1007/s11517-015-1314-7
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Since the advent of electromyogram recording, precise measures of tremor and gait have been used to study movement disorders such as Parkinson's disease. Now, a wide range of accelerometers and other motion-tracking technologies exist to better inform researchers and clinicians, yet such systems are rarely tested for accuracy or suitability before use. Our inexpensive test-rig can produce sinusoidal displacements using a simple cantilever system driven by a subwoofer. Controlled sinusoids were generated using computer software, and the displacement amplitudes of the test-rig were verified with fiducial marker tracking. To illustrate the use of the test-rig, we evaluated an accelerometer and an electromagnetic motion tracker. Accelerometry recordings were accurate to within +/- 0.09 g of actual peak-to-peak amplitude with a frequency response close to unity gain between 1 and 20 Hz. The electromagnetic sensor underestimated peak displacement by 2.68 mm, which was largely due to a diminishing gain with increasing frequency. Both sensors had low distortion. Overall sensitivity was limited by noise for the accelerometer and quantisation resolution for the electromagnetic sensor. Our simple and low-cost test-rig can be used to bench-test sensors used in movement disorders research. It was able to produce reliable sinusoidal displacements and worked across the 1- to 20-Hz frequency range.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 18 条
  • [1] Audacity Team, 2014, AUD 2 0 5
  • [2] The effectiveness of treatments for essential tremor
    Bain, PG
    [J]. NEUROLOGIST, 1997, 3 (05) : 305 - 321
  • [3] Billinghurst M, 2014, ARTOOLKIT BENCHMARKS
  • [4] Dosch J, 2007, IMAC 25
  • [5] Gravitational artifact in accelerometric measurements of tremor
    Elble, RJ
    [J]. CLINICAL NEUROPHYSIOLOGY, 2005, 116 (07) : 1638 - 1643
  • [6] Fahn S, 1993, MOVEMENT DISORD, V2, P271
  • [7] Fahn S., RECENT DEV PARKINSON, V2, P153
  • [8] Gade S, 2008, P IMAC 26 C EXP STRU
  • [9] Clinically Deployable Kinesia™ Technology for Automated Tremor Assessment
    Giuffrida, Joseph P.
    Riley, David E.
    Maddux, Brian N.
    Heldman, Dustin A.
    [J]. MOVEMENT DISORDERS, 2009, 24 (05) : 723 - 730
  • [10] Automated Assessment of Bradykinesia and Dyskinesia in Parkinson's Disease
    Griffiths, Robert I.
    Kotschet, Katya
    Arfon, Sian
    Xu, Zheng Ming
    Johnson, William
    Drago, John
    Evans, Andrew
    Kempster, Peter
    Raghav, Sanjay
    Horne, Malcolm K.
    [J]. JOURNAL OF PARKINSONS DISEASE, 2012, 2 (01) : 47 - 55