A simple and inexpensive test-rig for evaluating the performance of motion sensors used in movement disorders research
被引:8
作者:
Perera, Thushara
论文数: 0引用数: 0
h-index: 0
机构:
Bion Inst, 384-388 Albert St, East Melbourne, Vic 3002, AustraliaBion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
Perera, Thushara
[1
]
Yohanandan, Shivanthan A. C.
论文数: 0引用数: 0
h-index: 0
机构:
Bion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
Univ Melbourne, Dept Elect & Elect Engn, Parkville, Vic 3010, AustraliaBion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
Yohanandan, Shivanthan A. C.
[1
,2
]
McDermott, Hugh J.
论文数: 0引用数: 0
h-index: 0
机构:
Bion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
Univ Melbourne, Med Bion Dept, Parkville, Vic 3010, AustraliaBion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
McDermott, Hugh J.
[1
,3
]
机构:
[1] Bion Inst, 384-388 Albert St, East Melbourne, Vic 3002, Australia
Accelerometer;
Electromagnetic;
Movement disorders;
Motion tracking;
Tremor;
PARKINSONS-DISEASE;
TREMOR;
D O I:
10.1007/s11517-015-1314-7
中图分类号:
TP39 [计算机的应用];
学科分类号:
081203 ;
0835 ;
摘要:
Since the advent of electromyogram recording, precise measures of tremor and gait have been used to study movement disorders such as Parkinson's disease. Now, a wide range of accelerometers and other motion-tracking technologies exist to better inform researchers and clinicians, yet such systems are rarely tested for accuracy or suitability before use. Our inexpensive test-rig can produce sinusoidal displacements using a simple cantilever system driven by a subwoofer. Controlled sinusoids were generated using computer software, and the displacement amplitudes of the test-rig were verified with fiducial marker tracking. To illustrate the use of the test-rig, we evaluated an accelerometer and an electromagnetic motion tracker. Accelerometry recordings were accurate to within +/- 0.09 g of actual peak-to-peak amplitude with a frequency response close to unity gain between 1 and 20 Hz. The electromagnetic sensor underestimated peak displacement by 2.68 mm, which was largely due to a diminishing gain with increasing frequency. Both sensors had low distortion. Overall sensitivity was limited by noise for the accelerometer and quantisation resolution for the electromagnetic sensor. Our simple and low-cost test-rig can be used to bench-test sensors used in movement disorders research. It was able to produce reliable sinusoidal displacements and worked across the 1- to 20-Hz frequency range.
机构:
Cleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA
Giuffrida, Joseph P.
Riley, David E.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hosp Case Med Ctr, Movement Disorders Ctr, Neurol Inst, Cleveland, OH USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA
Riley, David E.
Maddux, Brian N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hosp Case Med Ctr, Movement Disorders Ctr, Neurol Inst, Cleveland, OH USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA
Maddux, Brian N.
Heldman, Dustin A.
论文数: 0引用数: 0
h-index: 0
机构:
Cleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA
机构:
Cleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA
Giuffrida, Joseph P.
Riley, David E.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hosp Case Med Ctr, Movement Disorders Ctr, Neurol Inst, Cleveland, OH USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA
Riley, David E.
Maddux, Brian N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hosp Case Med Ctr, Movement Disorders Ctr, Neurol Inst, Cleveland, OH USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA
Maddux, Brian N.
Heldman, Dustin A.
论文数: 0引用数: 0
h-index: 0
机构:
Cleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USACleveland Med Devices Inc, Div Movement Disorders, Cleveland, OH 44103 USA