Measurement of Temperature and H2O Concentration in Premixed CH4/Air Flame Using Two Partially Overlapped H2O Absorption Signals in the Near Infrared Region

被引:10
作者
So, Sunghyun [1 ,2 ]
Jeong, Nakwon [1 ,2 ]
Song, Aran [1 ,2 ]
Hwang, Jungho [2 ]
Kim, Daehae [1 ]
Lee, Changyeop [1 ]
机构
[1] Korea Inst Ind Technol, Ind Environm Green Deal Agcy, Cheonan 31056, South Korea
[2] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 08期
关键词
tunable diode laser absorption spectroscopy; temperature; concentration; partially overlapped absorption; premixed flame; HIGH-SPEED; LASER; SPECTROSCOPY; CO2; SENSOR; TDLAS; GAS;
D O I
10.3390/app11083701
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
It is important to monitor the temperature and H2O concentration in a large combustion environment in order to improve combustion (and thermal) efficiency and reduce harmful combustion emissions. However, it is difficult to simultaneously measure both internal temperature and gas concentration in a large combustion system because of the harsh environment with rapid flow. In regard, tunable diode laser absorption spectroscopy, which has the advantages of non-intrusive, high-speed response, and in situ measurement, is highly attractive for measuring the concentration of a specific gas species in the combustion environment. In this study, two partially overlapped H2O absorption signals were used in the tunable diode laser absorption spectroscopy (TDLAS) to measure the temperature and H2O concentration in a premixed CH4/air flame due to the wide selection of wavelengths with high temperature sensitivity and advantages where high frequency modulation can be applied. The wavelength regions of the two partially overlapped H2O absorptions were 1.3492 and 1.34927 mu m. The measured signals separated the multi-peak Voigt fitting. As a result, the temperature measured by TDLAS based on multi-peak Voigt fitting in the premixed CH4/air flame was the highest at 1385.80 K for an equivalence ratio of 1.00. It also showed a similarity to those tendencies to the temperature measured by the corrected R-type T/C. In addition, the H2O concentrations measured by TDLAS based on the total integrated absorbance area for various equivalent ratios were consistent with those calculated by the chemical equilibrium simulation. Additionally, the H2O concentration measured at an equivalence ratio of 1.15 was the highest at 18.92%.
引用
收藏
页数:16
相关论文
共 33 条
  • [1] [Anonymous], 2005, THESIS STANFORD U
  • [2] [Anonymous], GRI-Mech 3(0)
  • [3] Triplet-Graph Reasoning Network for Few-Shot Metal Generic Surface Defect Segmentation
    Bao, Yanqi
    Song, Kechen
    Liu, Jie
    Wang, Yanyan
    Yan, Yunhui
    Yu, Han
    Li, Xingjie
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [4] Tunable diode laser spectroscopy as a technique for combustion diagnostics
    Bolshov, M. A.
    Kuritsyn, Yu. A.
    Romanovskii, Yu. V.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 106 : 45 - 66
  • [5] Infrared laser-absorption sensing for combustion gases
    Goldenstein, Christopher S.
    Spearrin, R. Mitchell
    Jeffries, Jay B.
    Hanson, Ronald K.
    [J]. PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2017, 60 : 132 - 176
  • [6] Diode laser measurements of linestrength and temperature-dependent lineshape parameters of H2O-, CO2-, and N2-perturbed H2O transitions near 2474 and 2482 nm
    Goldenstein, Christopher S.
    Jeffries, Jay B.
    Hanson, Ronald K.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 130 : 100 - 111
  • [7] The HITRAN2016 molecular spectroscopic database
    Gordon, I. E.
    Rothman, L. S.
    Hill, C.
    Kochanov, R. V.
    Tan, Y.
    Bernath, P. F.
    Birk, M.
    Boudon, V.
    Campargue, A.
    Chance, K. V.
    Drouin, B. J.
    Flaud, J. -M.
    Gamache, R. R.
    Hodges, J. T.
    Jacquemart, D.
    Perevalov, V. I.
    Perrin, A.
    Shine, K. P.
    Smith, M. -A. H.
    Tennyson, J.
    Toon, G. C.
    Tran, H.
    Tyuterev, V. G.
    Barbe, A.
    Csaszar, A. G.
    Devi, V. M.
    Furtenbacher, T.
    Harrison, J. J.
    Hartmann, J. -M.
    Jolly, A.
    Johnson, T. J.
    Karman, T.
    Kleiner, I.
    Kyuberis, A. A.
    Loos, J.
    Lyulin, O. M.
    Massie, S. T.
    Mikhailenko, S. N.
    Moazzen-Ahmadi, N.
    Mueller, H. S. P.
    Naumenko, O. V.
    Nikitin, A. V.
    Polyansky, O. L.
    Rey, M.
    Rotger, M.
    Sharpe, S. W.
    Sung, K.
    Starikova, E.
    Tashkun, S. A.
    Vander Auwera, J.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2017, 203 : 3 - 69
  • [8] TEMPERATURE-MEASUREMENT TECHNIQUE FOR HIGH-TEMPERATURE GASES USING A TUNABLE DIODE-LASER
    HANSON, RK
    FALCONE, PK
    [J]. APPLIED OPTICS, 1978, 17 (16): : 2477 - 2480
  • [9] Hanson RonaldK., 2016, SPECTROSCOPY OPTICAL, V1
  • [10] Thermocouple error correction for measuring the flame temperature with determination of emissivity and heat transfer coefficient
    Hindasageri, V.
    Vedula, R. P.
    Prabhu, S. V.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (02)