A new way of two-terminal fault location for transmission lines based on strong tracking filter

被引:0
|
作者
Liu Meng [1 ]
Liu Suling [1 ]
机构
[1] Hebei Univ, Coll Phys Sci & Technol, Baoding, Peoples R China
关键词
strong tracking filter; sequence component; parameter estimation; two-terminal ranging method;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
When the high-voltage transmission lines break down, the fault point should be separated from the network. In order to locate the fault point quickly and accurately, a new fault location method of two-terminal based on sequence components and strong tracking filter theory is presented. This paper proposes a method that using the fault distance as the state variable and failure voltage and failure current measured at two terminals as input variables, the system state and parameter joint estimation model is built. Using method of strong tracking filter to estimate fault distance, fault location can be found within a short time after accident. Using sequence component equation can unify form of state equation regardless of the type of fault. MATLAB program with a large number of fault data shows that the method with short time of location and accurate results is a very effective way to fault location.
引用
收藏
页码:1047 / 1051
页数:5
相关论文
共 50 条
  • [1] Fault location on two-terminal transmission lines based on voltages
    Zamora, I
    Minambres, JF
    Mazon, AJ
    ALvarezIsasi, R
    Lazaro, J
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (01) : 1 - 6
  • [2] Fault location on two-terminal transmission lines based on voltages
    Basque Country Univ, Bilbao, Spain
    IEE Proc Gener Transm Distrib, 1 (1-6):
  • [3] Two-Terminal Fault Location on Unsymmetrical Transmission Lines
    Schulze, Roberto
    Schegner, Peter
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [4] A New Practical Fault Location Algorithm for Two-terminal Transmission Lines
    Ma, Zhou
    Li, Xiaoning
    Zhang, Xiaoming
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 4377 - +
  • [5] Fault location of two-terminal transmission lines with a small fault resistance
    Wu, JK
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 714 - 721
  • [6] New method of fault location on double-circuit two-terminal transmission lines
    Mazon, AJ
    Minambres, JF
    Zorrozua, MA
    Zamora, I
    AlvarezIsasi, R
    ELECTRIC POWER SYSTEMS RESEARCH, 1995, 35 (03) : 213 - 219
  • [7] Accurate and comprehensive fault location algorithm for two-terminal transmission lines
    Poudineh-Ebrahimi, Farhad
    Ghazizadeh-Ahsaee, Mahdi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (19) : 4334 - 4340
  • [8] A new approach to fault location in two-terminal transmission lines using artificial neural networks
    Mazon, AJ
    Zamora, I
    Miñambres, JF
    Zorrozua, MA
    Barandiaran, JJ
    Sagastabeitia, K
    ELECTRIC POWER SYSTEMS RESEARCH, 2000, 56 (03) : 261 - 266
  • [9] Two-terminal fault location algorithm uninfluenced by parameters of parallel transmission lines
    Xi'an Jiaotong University, Xi'an 710049, China
    Dianli Xitong Zidonghue, 2006, 24 (21-26+32):
  • [10] An Accurate Fault Location Algorithm for Two-Terminal Transmission Lines Combined with Parameter Estimation
    Che, Renfei