Calculation of electric fields induced by body and head motion in high-field MRI

被引:53
|
作者
Liu, F [1 ]
Zhao, HW [1 ]
Crozier, S [1 ]
机构
[1] Univ Queensland, Ctr Magnet Resonance, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
MRI; high magnetic field; induced current; human body model;
D O I
10.1016/S1090-7807(02)00180-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [41] Windows on the Human Body - in Vivo High-Field Magnetic Resonance Research and Applications in Medicine and Psychology
    Moser, Ewald
    Meyerspeer, Martin
    Fischmeister, Florian Ph. S.
    Grabner, Guenther
    Bauer, Herbert
    Trattnig, Siegfried
    SENSORS, 2010, 10 (06) : 5724 - 5757
  • [42] Preoperative staging of rectal cancer: Comparison of 3-T high-field MRI and endorectal sonography
    Chun, Ho-Kyung
    Choi, Dongil
    Kim, Min Ju
    Lee, Jongmee
    Yun, Seong Hyeon
    Kim, Seung Hoon
    Lee, Soon Jin
    Kim, Chan Kyo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) : 1557 - 1562
  • [43] Array-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI
    Collins, Christopher M.
    Wang, Zhangwei
    Mao, Weihua
    Fang, Jieming
    Liu, Wanzhan
    Smith, Michael B.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 470 - 474
  • [44] Definition of Ktrans and FA Thresholds for Better Assessment of Experimental Glioma Using High-field MRI: A Feasibility Study
    T. Engelhorn
    M. A. Schwarz
    A. Hess
    L. Budinsky
    P. Pitann
    I. Eyüpoglu
    A. Doerfler
    Clinical Neuroradiology, 2014, 24 : 337 - 345
  • [45] 3D characterization of the triple-bundle Achilles tendon from in vivo high-field MRI
    Cone, Stephanie G.
    Kim, Hoon
    Thelen, Darryl G.
    Franz, Jason R.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (10) : 2315 - 2321
  • [46] MICROCALCIFICATIONS IN CLINICALLY NORMAL BREAST - THE VALUE OF HIGH-FIELD, SURFACE COIL, GD-DTPA-ENHANCED MRI
    TESOROTESS, JD
    AMORUSO, A
    ROVINI, D
    BALZARINI, L
    CEGLIA, E
    CIVELLI, E
    TRECATE, G
    SAVIO, T
    MUSUMECI, R
    EUROPEAN RADIOLOGY, 1995, 5 (04) : 417 - 422
  • [47] The effects of the use of piezoelectric motors in a 1.5-Tesla high-field magnetic resonance imaging system (MRI)
    Wendt, O
    Oellinger, J
    Lüth, TC
    Felix, R
    Boenick, U
    BIOMEDIZINISCHE TECHNIK, 2000, 45 (1-2): : 20 - 25
  • [48] Definition of Ktrans and FA Thresholds for Better Assessment of Experimental Glioma Using High-field MRI: A Feasibility Study
    Engelhorn, T.
    Schwarz, M. A.
    Hess, A.
    Budinsky, L.
    Pitann, P.
    Eyuepoglu, I.
    Doerfler, A.
    CLINICAL NEURORADIOLOGY, 2014, 24 (04) : 337 - 345
  • [49] Cognitive effects of head-movements in stray fields generated by a 7 Tesla whole-body MRI magnet
    de Vocht, F.
    Stevens, T.
    Glover, P.
    Sunderland, A.
    Gowland, P.
    Kromhout, H.
    BIOELECTROMAGNETICS, 2007, 28 (04) : 247 - 255
  • [50] Peri-anaesthetic complications in 1798 equids undergoing high-field elective orthopaedic MRI at a tertiary referral hospital
    Manning, Heath
    Sampson, Sarah
    EQUINE VETERINARY JOURNAL, 2024, : 666 - 673