Voltammetric studies of a cobalt(II)-4-methylsalophen modified carbon-paste electrode and its application for the simultaneous determination of cysteine and ascorbic acid

被引:83
作者
Shahrokhian, S [1 ]
Karimi, M [1 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 113659515, Iran
关键词
ascorbic acid; cysteine; cobalt(II)-4-methylsalophen; carbon-paste electrode; modified electrode; electrocatalysis; cyclic voltammetry; differential pulse voltammetry;
D O I
10.1016/j.electacta.2004.07.015
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A carbon-paste electrode (CPE) chemically modified with the cobalt(II)-4-methylsalophen (CoMSal) as a Schiff base complex was used as a highly sensitive and fairly selective electrochemical sensor for simultaneous determination of minor mounts of ascorbic acid (AA) and cysteine. This modified electrode shows very efficient electrocatalytic activity for anodic oxidation of both AA and cysteine via substantially decreasing of anodic overpotentials for both compounds. The mechanism of electrochemical oxidation of both AA and cysteine using CoMSal-modified electrode was thoroughly investigated by cyclic voltammetry and polarization studies. Results of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using this modified electrode show two well-resolved anodic waves for the oxidation of AA and cysteine, which makes it possible for simultaneous determination of both compounds. A linear range of 1 x 10(-4) to 5 x 10(-7) M for cysteine in a constant concentration of 1 x 10(-4) M AA in buffered solution (as a background electrolyte) was obtained from DPV measurements using this electrode. The linear range, which is obtained for AA in the presence of 1 x 10(-4) M cysteine, was in the range of 1 x 10(-4) to 1 x 10(-6) M. The modified electrode has good reproducibility (RSD less than or equal to 2.5%), low detection limit (sub-micromolar) and high sensitivity for the detection of both AA and cysteine with a very high stability in its voltammetric response. Differential pulse voltammetry using the modified electrode exhibited a reasonable recovery for a relatively wide concentration range of cysteine spiked to a synthetic human serum sample. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 41 条
[1]   Capability of a carbon-polyvinylchloride composite electrode for the detection of dopamine, ascorbic acid and uric acid [J].
Aguilar, R ;
Dávila, MM ;
Elizalde, MP ;
Mattusch, J ;
Wennrich, R .
ELECTROCHIMICA ACTA, 2004, 49 (06) :851-859
[2]  
Aguirre MJ, 1998, ELECTROANAL, V10, P571
[3]   PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2502-2505
[4]   Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine [J].
Amini, MK ;
Khorasani, JH ;
Khaloo, SS ;
Tangestaninejad, S .
ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) :32-38
[5]   Iron(II) phthalocyanine-modified carbon-paste electrode for potentiometric detection of ascorbic acid [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S ;
Mirkhani, V .
ANALYTICAL BIOCHEMISTRY, 2001, 290 (02) :277-282
[6]   A new class of aluminum cations based upon tetradentate (N2O2) chelating ligands [J].
Atwood, DA ;
Jegier, JA ;
Rutherford, D .
INORGANIC CHEMISTRY, 1996, 35 (01) :63-70
[7]  
BARD AJ, 2001, ELECTROCHEMICAL METH, pCH12
[8]  
BELLI SL, 1986, ANAL LETT, V19, P403
[9]  
Clemetson C.A.B., 1989, VITAMIN C
[10]   Determination of pharmaceutical thiols by liquid chromatography with electrochemical detection: Use of an electrode with a conductive carbon cement matrix, chemically modified with cobalt phthalocyanine [J].
Favaro, G ;
Fiorani, M .
ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) :249-255