Baseline wander correction in pulse waveforms using wavelet-based cascaded adaptive filter

被引:71
作者
Xu, Lisheng
Zhang, David [1 ]
Wang, Kuanquan
Li, Naimin
Wang, Xiaoyun
机构
[1] Hong Kong Polytech Univ, Dept Comp, Kowloon, Hong Kong, Peoples R China
[2] Harbin Inst Technol, Dept Comp Sci & Technol, Harbin 150006, Peoples R China
[3] Harbin Med Univ, Affiliated Hosp 4, Dept Cardiol, Harbin, Peoples R China
基金
中国国家自然科学基金;
关键词
baseline wander; cubic spline estimation; FIR filter; pulse diagnosis; pulse waveform; Meyer wavelet;
D O I
10.1016/j.compbiomed.2006.06.014
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Pulse diagnosis is a convenient, inexpensive, painless, and non-invasive diagnosis method. Quantifying pulse diagnosis is to acquire and record pulse waveforms by a set of sensor firstly, and then analyze these pulse waveforms. However, respiration and artifact motion during pulse waveform acquisition can introduce baseline wander. It is necessary, therefore, to remove the pulse waveform's baseline wander in order to perform accurate pulse waveform analysis. This paper presents a wavelet-based cascaded adaptive filter (CAF) to remove the baseline wander of pulse waveform. To evaluate the level of baseline wander, we introduce a criterion: energy ratio (ER) of pulse waveform to its baseline wander. If the ER is more than a given threshold, the baseline wander can be removed only by cubic spline estimation; otherwise it must be filtered by, in sequence, discrete Meyer wavelet filter and the cubic spline estimation. Compared with traditional methods such as cubic spline estimation, morphology filter and Linear-phase finite impulse response (FIR) least-squares-error digital filter, the experimental results on 50 simulated and 500 real pulse signals demonstrate the power of CAF filter both in removing baseline wander and in preserving the diagnostic information of pulse waveforms. This CAF filter also can be used to remove the baseline wander of other physiological signals, such as ECG and so on. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:716 / 731
页数:16
相关论文
共 35 条
[1]   Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes [J].
Allen, J ;
Murray, A .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2000, 147 (06) :403-407
[2]  
[Anonymous], 1993, Ten Lectures of Wavelets
[3]   Accuracy of radial artery blood pressure determination with the Vasotrac™ [J].
Belani, KG ;
Buckley, JJ ;
Poliac, MO .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (05) :488-496
[4]  
BIAN Q, 1979, CLASSIC DIFFICULTIES
[5]  
Chiu CC, 1997, P ANN INT IEEE EMBS, V19, P1394, DOI 10.1109/IEMBS.1997.756642
[6]  
CONFORTO S, 1999, J ELECTROMYOGR KINES, P47
[7]   A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS [J].
FRIESEN, GM ;
JANNETT, TC ;
JADALLAH, MA ;
YATES, SL ;
QUINT, SR ;
NAGLE, HT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :85-98
[8]   A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function [J].
Gratze, G ;
Fortin, J ;
Holler, A ;
Grasenick, K ;
Pfurtscheller, G ;
Wach, P ;
Schonegger, J ;
Kotanko, P ;
Skrabal, F .
COMPUTERS IN BIOLOGY AND MEDICINE, 1998, 28 (02) :121-142
[9]  
Huh W., 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. `Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136), P2406, DOI 10.1109/IEMBS.1997.756806
[10]  
INUKAI, 1998, Patent No. 5830148