Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose

被引:22
|
作者
Bodelle, Boris [1 ]
Fischbach, Constanze [1 ]
Booz, Christian [1 ]
Yel, Ibrahim [1 ]
Frellesen, Claudia [1 ]
Beeres, Martin [1 ]
Vogl, Thomas J. [1 ]
Scholtz, Jan-Erik [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
High pitch CT; Third generation dual-source CT; Free breathing; Pediatric CT; Chest CT; FILTERED BACK-PROJECTION; AFFIRMED ITERATIVE RECONSTRUCTION; ADVERSE EVENTS; CT; SEDATION; CHILDREN; CANCER; RISKS;
D O I
10.1016/j.ejrad.2017.01.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80 kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). Materials and methods: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1 +/- 4.9 years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n = 31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n = 56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Results: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p > 0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p < 0.01). Motion artifacts were reduced significantly (p = 0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p < 0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82 mGy vs. 0.92 mGy, p < 0.02; median ED: 0.4 mSv vs. 0.48 mSv, p = 0.02). Conclusions: High-pitch 80 kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 50 条
  • [31] Accuracy of Combined Computed Tomography Colonography and Dual Energy Iiodine Map Imaging for Detecting Colorectal masses using High-pitch Dual-source CT
    Sun, Kai
    Han, Ruijuan
    Han, Yang
    Shi, Xuesen
    Hu, Jiang
    Lu, Bin
    SCIENTIFIC REPORTS, 2018, 8
  • [32] Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography
    Miura, Hideharu
    Ozawa, Shuichi
    Okazue, Toshiya
    Kawakubo, Atsushi
    Yamada, Kiyoshi
    Nagata, Yasushi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 360 - 366
  • [33] Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study
    Hwang, Sung Ho
    Oh, Yu-Whan
    Ham, Soo-Youn
    Kang, Eun-Young
    Lee, Ki Yeol
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 641 - 647
  • [34] Prospective ECG-gated high-pitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities: Radiation dose and diagnostic efficacy in a pediatric population
    Koplay, M.
    Kizilca, O.
    Cimen, D.
    Sivri, M.
    Erdogan, H.
    Guvenc, O.
    Oc, M.
    Oran, B.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (11) : 1141 - 1150
  • [35] Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography
    May, Matthias S.
    Wuest, Wolfgang
    Brand, Michael
    Stahl, Christian
    Allmendinger, Thomas
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 465 - 470
  • [36] High-pitch non-gated scans on the second and third generation dual-source CT scanners: comparison of coronary image quality
    Lin, Cheng Ting
    Chu, Linda Chi Hang
    Zimmerman, Stefan Loy
    Fishman, Elliot K.
    CLINICAL IMAGING, 2020, 59 (01) : 45 - 49
  • [37] High-pitch coronary CT angiography in dual-source CT during free breathing vs. breath holding in patients with low heart rates
    Bischoff, Bernhard
    Meinel, Felix G.
    Del Prete, Alessandra
    Reiser, Maximilian F.
    Becker, Hans-Christoph
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2217 - 2221
  • [38] Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT
    Agostini, Andrea
    Mari, Alberto
    Lanza, Cecilia
    Schicchi, Nicolo
    Borgheresi, Alessandra
    Maggi, Stefania
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (08): : 745 - 752
  • [39] Contrast-Enhanced High-Pitch Computed Tomography in Pediatric Patients Without Electrocardiography Triggering and Sedation: Comparison of Cardiac Image Quality With Conventional Multidetector Computed Tomography
    Esser, Michael
    Gatidis, Sergios
    Teufel, Matthias
    Ketelsen, Ines
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Tsiflikas, Ilias
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 165 - 171
  • [40] Image quality of ultra-low-dose dual-source CT angiography using high-pitch spiral acquisition and iterative reconstruction in young children with congenital heart disease
    Zheng, Minwen
    Zhao, Hongliang
    Xu, Jian
    Wu, Yongjie
    Li, Jian
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (06) : 376 - 382