Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose

被引:22
|
作者
Bodelle, Boris [1 ]
Fischbach, Constanze [1 ]
Booz, Christian [1 ]
Yel, Ibrahim [1 ]
Frellesen, Claudia [1 ]
Beeres, Martin [1 ]
Vogl, Thomas J. [1 ]
Scholtz, Jan-Erik [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
High pitch CT; Third generation dual-source CT; Free breathing; Pediatric CT; Chest CT; FILTERED BACK-PROJECTION; AFFIRMED ITERATIVE RECONSTRUCTION; ADVERSE EVENTS; CT; SEDATION; CHILDREN; CANCER; RISKS;
D O I
10.1016/j.ejrad.2017.01.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80 kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). Materials and methods: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1 +/- 4.9 years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n = 31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n = 56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Results: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p > 0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p < 0.01). Motion artifacts were reduced significantly (p = 0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p < 0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82 mGy vs. 0.92 mGy, p < 0.02; median ED: 0.4 mSv vs. 0.48 mSv, p = 0.02). Conclusions: High-pitch 80 kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 50 条
  • [1] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [2] High-pitch Dual-source Computed Tomography Pulmonary Angiography in Freely Breathing Patients
    Bauer, Ralf W.
    Schell, Boris
    Beeres, Martin
    Wichmann, Julian L.
    Bodelle, Boris
    Vogl, Thomas J.
    Kerl, Josef Matthias
    JOURNAL OF THORACIC IMAGING, 2012, 27 (06) : 376 - 381
  • [3] Feasibility of high-pitch dual-source low-dose chest CT: Reduction of radiation and cardiac artifacts
    Lim, H. K.
    Ha, H. I.
    Hwang, H. J.
    Lee, K.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 443 - 449
  • [4] Radiation Dose and Image Quality in Pediatric Cardiac Computed Tomography: A Comparison Between Sequential and Third-Generation Dual-Source High-Pitch Spiral Techniques
    Koh, Huiliang
    Ong, Ching Ching
    Choo, Yun Song
    Liang, Chong Ri
    Tan, Grace Hui Zhen
    Lim, Terence Chee Wen
    Quek, Swee Chye
    Sriram, Shankar
    San Teo, Lynette Li
    PEDIATRIC CARDIOLOGY, 2016, 37 (08) : 1397 - 1403
  • [5] Image quality and radiation dose of dual source high pitch computed tomography in pediatric congenital heart disease
    Kravchenko, Dmitrij
    Hart, Christopher
    Garbe, Stephan
    Luetkens, Julian A.
    Isaak, Alexander
    Mesropyan, Narine
    Vergnat, Mathieu
    Leyens, Judith
    Attenberger, Ulrike
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [6] Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents
    Christian A. Barrera
    Hansel J. Otero
    Ammie M. White
    David Saul
    David M. Biko
    The International Journal of Cardiovascular Imaging, 2019, 35 : 367 - 374
  • [7] Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents
    Barrera, Christian A.
    Otero, Hansel J.
    White, Ammie M.
    Saul, David
    Biko, David M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (02) : 367 - 374
  • [8] High-pitch dual-source paranasal sinus CT in agitated patients with maxillofacial trauma: analysis of image quality, motion artifacts, and dose aspects
    Frellesen, Claudia
    Wichmann, Julian L.
    Tischendorf, Patricia
    Scholtz, Jan-Erik
    Beeres, Martin
    Vogl, Thomas J.
    Bauer, Ralf W.
    ACTA RADIOLOGICA, 2018, 59 (08) : 909 - 916
  • [9] High-Pitch Computed Tomography of the Lung in Pediatric Patients: An Intraindividual Comparison of Image Quality and Radiation Dose to Conventional 64-MDCT
    Tsiflikas, I.
    Thomas, C.
    Ketelsen, D.
    Seitz, G.
    Warmann, S.
    Claussen, C. D.
    Schaefer, J. F.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 585 - 590
  • [10] High-pitch Helical Dual-source Computed Tomographic Pulmonary Angiography Comparing Image Quality in Inspiratory Breath-hold and During Free Breathing
    Ajlan, Amr M.
    Binzaqr, Salma
    Jadkarim, Dalia A.
    Jamjoom, Lamia G.
    Leipsic, Jonathon