Validity and reliability of the Danish version of the 9-item European Heart Failure Self-care Behavior Scale

被引:12
作者
Ostergaard, Birte [1 ,2 ]
Mahrer-Imhof, Romy [3 ]
Lauridsen, Jorgen [4 ]
Wagner, Lis [1 ]
机构
[1] Univ Southern Denmark, Clin Inst, Fac Hlth, Campusvej 55, DK-5230 Odense M, Denmark
[2] Odense Univ Hosp, OPEN Odense Patient Data Explorat Network, Odense, Denmark
[3] Zurich Univ Appl Sci, Inst Nursing, Zurich, Switzerland
[4] Univ Southern Denmark, COHERE, Dept Business & Econ, Odense, Denmark
关键词
heart failure; patient compliance; psychometrics; self-care; CROSS-CULTURAL ADAPTATION; FACTORIAL STRUCTURE; ASSOCIATION; VALIDATION; MANAGEMENT; ADHERENCE; SOCIETY;
D O I
10.1111/scs.12342
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
ObjectiveTo assess the self-care of patients with heart failure (HF), reliable and validated instruments are needed. The aim of this study was to test the validity and reliability of the Danish version of the European Heart Failure Self-care Behavior Scale (EHFScBS-9) based on previous studies reporting 1, 2 and 3 factors, respectively. MethodsA convenience sample of 147 patients with HF completed the EHFScBS-9. Psychometric properties of the Danish version of the EHFScBS-9 were tested with factor loadings, factor correlations and goodness-of-fit indices for four different measurement models based on confirmatory factor analysis. ResultsAll of the items, except item 9 about regular exercise, demonstrated satisfactory item-total correlation 0.30. Regarding the fit of the models on the sample data, the most superior fit was observed for the two-factor solution in terms of root-mean-square error of approximation (RMSEA), goodness-of-fit index (GFI), adjusted GFI (AGFI) and comparative fit index (CFI), which all reached the predefined threshold value, except for the normed fit index (NFI) at 0.90. Factor score determinacy (FSD) for the four models tested was 0.88 for the one-factor solution, 0.54 and 0.87 for the two-factor model, 0.83-0.55 for the first three-factor model and 0.87-0.38 for the second three-factor model. ConclusionsThe EHFScBS-9 questionnaire is a valid and reliable instrument to assess heart failure-specific self-care behaviours in a Danish population.
引用
收藏
页码:405 / 412
页数:8
相关论文
共 37 条
[1]   Clinical definition and epidemiology of advanced heart failure [J].
Adams, KF ;
Zannad, F .
AMERICAN HEART JOURNAL, 1998, 135 (06) :S204-S215
[2]  
[Anonymous], 2000, JAMA, V284, P3043
[3]  
[Anonymous], CARDIOVASCULAR DIS 2
[4]  
[Anonymous], MULTICENTER STUDY FA
[5]   Sample size used to validate a scale: A review of publications on newly-developed patient reported outcomes measures [J].
Anthoine E. ;
Moret L. ;
Regnault A. ;
Sbille V. ;
Hardouin J.-B. .
Health and Quality of Life Outcomes, 12 (1)
[6]   Reliability and validity of the compliance belief scales among patients with heart failure [J].
Bennett, SJ ;
Perkins, SM ;
Lane, KA ;
Forthofer, MA ;
Brater, DC ;
Murray, MD .
HEART & LUNG, 2001, 30 (03) :177-185
[7]  
Cameron Jan, 2009, J Cardiovasc Nurs, V24, pE10, DOI 10.1097/JCN.0b013e3181b5660f
[8]   Cross-cultural adaptation and validation of the European Heart Failure Self-care Behavior Scale for Brazilian Portuguese [J].
Feijo, Maria Karolina ;
Avila, Christiane Wahast ;
de Souza, Emiliane Nogueira ;
Jaarsma, Tiny ;
Rabelo, Eneida Rejane .
REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2012, 20 (05) :988-996
[9]   FOCUS ON PSYCHOMETRICS - ASPECTS OF ITEM ANALYSIS [J].
FERKETICH, S .
RESEARCH IN NURSING & HEALTH, 1991, 14 (02) :165-168
[10]  
Hair FJ., 1998, Multivariate Data Analysis (Fifth ed.)