Locking plate combined with titanium cable for Neer type II distal clavicle fractures

被引:7
作者
Zhang, Fan [1 ]
Fu, Qiang [1 ]
Li, Yongchuan [1 ]
Lu, Nan [1 ]
Chen, Aimin [1 ]
Zhao, Liangyu [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthopaed, 415 Fengyang Rd, Shanghai 200003, Peoples R China
关键词
Distal clavicle fractures; Neer type II; Combined surgical strategy; Locking plate; Titanium cable; Coracoclavicular stabilization;
D O I
10.1186/s12891-021-04137-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThere is controversy about the optimal strategy treatment of unstable distal clavicle fractures. We explored use of a surgical strategy: combination of a distal clavicle locking plate and a titanium cable. The purpose of this retrospective case series study was to evaluate the clinical outcomes of this new strategy in treating Neer type II distal clavicle fractures.MethodsTwenty-one patients with Neer type II distal clavicle fracture were treated with a distal clavicle locking plate and a titanium cable. All patients were followed for at least one year. We retrospectively collected and reviewed follow-up data. The clinical outcomes were assessed for union rate, functional score, and complication rate.ResultsAll patients achieved bony union within 6 months. The average follow-up period was 20.6 months (range12-48 months). The mean Constant score at one-year follow-up was 94.63.3 (range 84-98), and the mean UCLA (University of California, Los Angeles) score was 33.3 +/- 2.6 (range 27-35). Only one complication (wound infection) was observed during follow-up. Two patients received another operation for implant removal due to local irritation.Conclusions Use of a distal clavicle locking plate in combination with a titanium cable for treatment of Neer type II fractures results in high union rate, a low complication rate, and good shoulder function. This combined surgical strategy can be considered an effective method for treating unstable distal clavicle fractures.
引用
收藏
页数:9
相关论文
共 27 条
[1]   Precontoured Superior Locked Plating of Distal Clavicle Fractures: A New Strategy [J].
Andersen, Jaron R. ;
Willis, Matt P. ;
Nelson, Ryan ;
Mighell, Mark A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) :3344-3350
[2]   What Regions of the Distal Clavicle Have the Greatest Bone Mineral Density and Cortical Thickness? A Cadaveric Study [J].
Chen, Raymond E. ;
Soin, Sandeep P. ;
El-Shaar, Rami ;
Nicandri, Gregg T. ;
Awad, Hani A. ;
Maloney, Michael D. ;
Voloshin, Ilya .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2019, 477 (12) :2726-2732
[3]   Coracoclavicular stabilization using a suture button device for Neer type IIB lateral clavicle fractures [J].
Cho, Chul-Hyun ;
Jung, Jae-Hoon ;
Kim, Beom-Soo .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (05) :804-808
[4]   Treatment of Neer IIb Distal Clavicle Fractures Using Anatomical Locked Plate Fixation With Coracoclavicular Ligament Augmentation [J].
Han, Lei ;
Hu, Yungen ;
Quan, Renfu ;
Fang, Weili ;
Jin, Bo ;
Huang, Ligang .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (12) :1036.e1-1036.e6
[5]   Stabilisation of vertical unstable distal clavicular fractures (Neer 2b) using locking T-plates and suture anchors [J].
Herrmann, S. ;
Schmidmaier, G. ;
Greiner, S. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (03) :236-239
[6]  
Johnston PS, 2014, J ORTHOP TRAUMA, V28, pE269, DOI 10.1097/BOT.0000000000000081
[7]   A method for internal fixation of unstable distal clavicle fractures: Early observations using a new technique [J].
Kalamaras, Michael ;
Cutbush, Ken ;
Robinson, Mark .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (01) :60-62
[8]   Management of acute unstable distal clavicle fracture with a modified coracoclavicular stabilization technique using a bidirectional coracoclavicular loop system [J].
Kanchanatawan W. ;
Wongthongsalee P. .
European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (2) :139-143
[9]   Surgical treatment of distal clavicle fractures using the clavicular hook plate [J].
Kashii, Masafumi ;
Inui, Hiroaki ;
Yamamoto, Kouji .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) :158-164
[10]   Fractures of the Clavicle [J].
Khan, L. A. Kashif ;
Bradnock, Timothy J. ;
Scott, Caroline ;
Robinson, C. Michael .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (02) :447-460