Circulating calprotectin as biomarker in neutrophil-related inflammation: Pre-analytical recommendations and reference values according to sample type

被引:26
作者
Mylemans, Marnix [1 ]
Nevejan, Louis [1 ]
Van Den Bremt, Stefanie [1 ]
Stubbe, Muriel [2 ]
Cruyssen, Bert Vander [2 ]
Moulakakis, Christina [3 ]
Berthold, Heike [3 ]
Konrad, Christian [3 ]
Bossuyt, Xavier [4 ,5 ]
Van Hoovels, Lieve [1 ,5 ]
机构
[1] Onze Lieve Vrouw Hosp, Dept Lab Med, Moorselbaan 164, B-9300 Aalst, Belgium
[2] Onze Lieve Vrouw Hosp, Dept Rheumatol, Aalst, Belgium
[3] Thermo Fisher Sci, Freiburg, Germany
[4] Univ Hosp Leuven, Dept Lab Med, Leuven, Belgium
[5] Katholieke Univ Leuven, Dept Microbiol & Immunol, Leuven, Belgium
关键词
Circulating calprotectin; Biomarker; Neutrophil-related inflammation; Reference values; Pre-analytical phase; RHEUMATOID-ARTHRITIS; SERUM CALPROTECTIN; DISEASE-ACTIVITY; CALCIUM-BINDING; ASSOCIATION; S100A8/A9; PROTEINS; PLASMA; MARKER; LEVEL;
D O I
10.1016/j.cca.2021.02.022
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Calprotectin (CLP) is a promising biomarker for the evaluation of neutrophil-related inflammation. Our aim was to establish reference values for circulating CLP in different sample types and to study the effect of pre-analytical variables. Methods: Reference values were determined in 100 healthy individuals. Pre-analytical variables were evaluated in 10 healthy controls and four rheumatoid arthritis patients with active disease and covered sample type (serum with/without gel separator, heparin, EDTA and citrate plasma), pre-centrifugation time (<2 h, 6 h, 24 h), storage condition (2-8 degrees C, 18-25 degrees C, 30 degrees C) and storage time (24 h, 72 h, 7 days). CLP measurements were performed with the EliA (TM) Calprotectin 2 assay on Phadia (TM) 200 (Thermo Fisher Scientific). Results: In healthy controls, baseline CLP concentrations in serum were more than double the concentration in EDTA and citrate plasma (0.909 mu g/mL versus 0.259 mu g/mL and 0.261 mu g/mL respectively). Heparin, EDTA and citrate stabilized CLP concentrations for up to 6 h before centrifugation, whereas significant increases in CLP levels were observed when serum was left untreated during that time period. Conclusion: Clinical studies on circulating CLP need to apply sample type-specific reference values and decision limits. To obtain reproducible CLP results in serum, more stringent pre-analytical sample handling instructions are needed.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 42 条
[41]   Increased expression of S100A8 and S100A9 in patients with diffuse cutaneous systemic sclerosis. A correlation with organ involvement and immunological abnormalities [J].
Xu, Xue ;
Wu, Wen-yu ;
Tu, Wen-zheng ;
Chu, Hai-yan ;
Zhu, Xiao-xia ;
Liang, Min-rui ;
Xue, Yu ;
Wang, Jiu-cun ;
Zou, He-jian .
CLINICAL RHEUMATOLOGY, 2013, 32 (10) :1501-1510
[42]   Biomarkers in Remission According to Different Criteria in Patients with Rheumatoid Arthritis [J].
Yilmaz-Oner, Sibel ;
Ozen, Gulsen ;
Can, Meryem ;
Atagunduz, Pamir ;
Direskeneli, Haner ;
Inanc, Nevsun .
JOURNAL OF RHEUMATOLOGY, 2015, 42 (11) :2066-2070