共 42 条
Circulating calprotectin as biomarker in neutrophil-related inflammation: Pre-analytical recommendations and reference values according to sample type
被引:26
作者:
Mylemans, Marnix
[1
]
Nevejan, Louis
[1
]
Van Den Bremt, Stefanie
[1
]
Stubbe, Muriel
[2
]
Cruyssen, Bert Vander
[2
]
Moulakakis, Christina
[3
]
Berthold, Heike
[3
]
Konrad, Christian
[3
]
Bossuyt, Xavier
[4
,5
]
Van Hoovels, Lieve
[1
,5
]
机构:
[1] Onze Lieve Vrouw Hosp, Dept Lab Med, Moorselbaan 164, B-9300 Aalst, Belgium
[2] Onze Lieve Vrouw Hosp, Dept Rheumatol, Aalst, Belgium
[3] Thermo Fisher Sci, Freiburg, Germany
[4] Univ Hosp Leuven, Dept Lab Med, Leuven, Belgium
[5] Katholieke Univ Leuven, Dept Microbiol & Immunol, Leuven, Belgium
关键词:
Circulating calprotectin;
Biomarker;
Neutrophil-related inflammation;
Reference values;
Pre-analytical phase;
RHEUMATOID-ARTHRITIS;
SERUM CALPROTECTIN;
DISEASE-ACTIVITY;
CALCIUM-BINDING;
ASSOCIATION;
S100A8/A9;
PROTEINS;
PLASMA;
MARKER;
LEVEL;
D O I:
10.1016/j.cca.2021.02.022
中图分类号:
R446 [实验室诊断];
R-33 [实验医学、医学实验];
学科分类号:
1001 ;
摘要:
Background: Calprotectin (CLP) is a promising biomarker for the evaluation of neutrophil-related inflammation. Our aim was to establish reference values for circulating CLP in different sample types and to study the effect of pre-analytical variables. Methods: Reference values were determined in 100 healthy individuals. Pre-analytical variables were evaluated in 10 healthy controls and four rheumatoid arthritis patients with active disease and covered sample type (serum with/without gel separator, heparin, EDTA and citrate plasma), pre-centrifugation time (<2 h, 6 h, 24 h), storage condition (2-8 degrees C, 18-25 degrees C, 30 degrees C) and storage time (24 h, 72 h, 7 days). CLP measurements were performed with the EliA (TM) Calprotectin 2 assay on Phadia (TM) 200 (Thermo Fisher Scientific). Results: In healthy controls, baseline CLP concentrations in serum were more than double the concentration in EDTA and citrate plasma (0.909 mu g/mL versus 0.259 mu g/mL and 0.261 mu g/mL respectively). Heparin, EDTA and citrate stabilized CLP concentrations for up to 6 h before centrifugation, whereas significant increases in CLP levels were observed when serum was left untreated during that time period. Conclusion: Clinical studies on circulating CLP need to apply sample type-specific reference values and decision limits. To obtain reproducible CLP results in serum, more stringent pre-analytical sample handling instructions are needed.
引用
收藏
页码:149 / 155
页数:7
相关论文