Significant Dose Reduction for Pediatric Digital Subtraction Angiography Without Impairing Image Quality: Preclinical Study in a Piglet Model

被引:14
作者
Racadio, John [1 ]
Strauss, Keith [2 ]
Abruzzo, Todd [1 ]
Patel, Manish [1 ]
Kukreja, Kamlesh [1 ]
Johnson, Neil [1 ]
den Hartog, Mark [3 ]
Hoornaert, Bart [3 ]
Nachabe, Rami [1 ]
机构
[1] Cincinnati Childrens Hosp, Dept Radiol, Div Pediat Intervent Radiol, Cincinnati, OH 45229 USA
[2] Childrens Hosp, Dept Radiol, Cincinnati Hosp, Cincinnati, OH 45229 USA
[3] Philips Healthcare, Intervent Xray Dept, Best, Netherlands
关键词
digital subtraction angiography (DSA); dose reduction; image quality; pediatrics; INTERVENTIONAL RADIOLOGY; EMBOLIZATION; CHILDREN; CANCER;
D O I
10.2214/AJR.13.12170
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to validate the hypothesis that image quality of digital subtraction angiography (DSA) in pediatrics is not impaired when using a low-dose acquisition protocol. MATERIALS AND METHODS. Three piglets corresponding to common pediatric population sizes were used. DSA was performed in the aorta and renal, hepatic, and superior mesenteric arteries using both the commonly used reference standard and novel radiographic imaging noise reduction technologies to ensure pairwise radiation dose and image quality comparison. The air kerma per frame at the interventional reference point for each DSA acquisition was collected as a radiation dose measure, and image quality was evaluated by five interventional radiologists in a randomized blinded fashion using a 5-point scale. RESULTS. The mean air kerma (+/- SD) at the interventional reference point with the novel x-ray imaging noise reduction technology was significantly lower (1.1 +/- 0.8 mGy/frame) than with the reference technology (4.2 +/- 3.0 mGy/frame, p = 0.005). However, image quality was statistically similar, with average scores of 3.2 +/- 0.4 and 3.1 +/- 0.5 for the novel and reference technologies, respectively (p = 0.934); interrater absolute agreement was 0.77. CONCLUSION. The DSA radiation dose for pediatrics can be reduced by a factor of four with a novel x-ray imaging noise reduction technology without deterioration of image quality.
引用
收藏
页码:904 / 908
页数:5
相关论文
共 18 条
  • [1] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [2] Pediatric Vascular Malformations: Pathophysiology, Diagnosis, and the Role of Interventional Radiology
    Cahill, Anne Marie
    Nijs, Els Louisa Francine
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (04) : 691 - 704
  • [3] Adult patient doses in interventional neuroradiology
    Gkanatsios, NA
    Huda, W
    Peters, KR
    [J]. MEDICAL PHYSICS, 2002, 29 (05) : 717 - 723
  • [4] Embolization for pediatric blunt splenic injury is an alternative to splenectomy when observation fails
    Gross, Jessica L.
    Woll, Nicole L.
    Hanson, Carol A.
    Pohl, Christoph
    Scorpio, Ronald J.
    Kennedy, Alfred P., Jr.
    Coppola, Christopher P.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2013, 75 (03) : 421 - 425
  • [5] Metastatic renal cell carcinoma to the thyroid gland
    Heffess, CS
    Wenig, BM
    Thompson, LD
    [J]. CANCER, 2002, 95 (09) : 1869 - 1878
  • [6] DOSE-AREA PRODUCT OF PATIENTS UNDERGOING DIGITAL SUBTRACTION ANGIOGRAPHY (DSA): ABDOMINAL AORTA AND LOWER LIMB EXAMINATIONS
    Juszkat, R.
    Blaszak, M. A.
    Majewska, N.
    Majewski, W.
    [J]. HEALTH PHYSICS, 2009, 96 (01): : 13 - 18
  • [7] Endovascular treatment for pediatric intracranial aneurysms
    Lv, Xianli
    Jiang, Chuhan
    Li, Youxiang
    Yang, Xinjian
    Wu, Zhongxue
    [J]. NEURORADIOLOGY, 2009, 51 (11) : 749 - 754
  • [8] Pediatric Arterial Interventions
    Marshalleck, Francis
    [J]. TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 13 (04) : 238 - 243
  • [9] Estimating Effective Dose to Pediatric Patients Undergoing Interventional Radiology Procedures Using Anthropomorphic Phantoms and MOSFET Dosimeters
    Miksys, Nelson
    Gordon, Christopher L.
    Thomas, Karen
    Connolly, Bairbre L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : 1315 - 1322
  • [10] Racadio J M, 1999, Semin Pediatr Surg, V8, P181